Fast-spin-echo versus rapid gradient-echo for 3D magnetization-prepared acquisitions: Application to inhomogeneous magnetization transfer

被引:1
|
作者
Taso, Manuel [1 ,2 ]
Munsch, Fanny [1 ,2 ]
Girard, Olivier M. [3 ]
Duhamel, Guillaume [3 ]
Alsop, David C. [1 ,2 ]
Varma, Gopal [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Div MRI Res, 330 Brookline Ave,Ansin 244, Boston, MA 02215 USA
[2] Harvard Med Sch, Boston, MA 02115 USA
[3] Aix Marseille Univ, CNRS, CRMBM, Marseille, France
关键词
fast-spin-echo; inhomogeneous magnetization transfer; myelin imaging; signal-to-noise; volumetric imaging; BROADENED LINES IHMT; SENSITIVITY; IMAGE; MRI; T-1; RELAXATION; PULSES;
D O I
10.1002/mrm.29461
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate the benefits of fast spin echo (FSE) imaging over rapid gradient-echo (RAGE) for magnetization-prepared inhomogeneous magnetization transfer (ihMT) imaging. Methods A 3D FSE sequence was modified to include an ihMT preparation (ihMT-FSE) with an optional CSF suppression based on an inversion-recovery (ihMT-FLAIR). After numeric simulations assessing SNR benefits of FSE and the potential impact of an additional inversion-recovery, ihMT-RAGE, ihMT-FSE, and ihMT-FLAIR sequences were compared in a group of six healthy volunteers, evaluating image quality, thermal, and physiological noise as well as quantification using an ihMT saturation (ihMTsat) approach. A preliminary exploration in the cervical spinal cord was also conducted in a group of three healthy volunteers. Results Several fold improvements in thermal SNR were observed with ihMT-FSE in agreement with numerical simulations. However, we observed significantly higher physiological noise in ihMT-FSE compared to ihMT-RAGE that was mitigated in ihMT-FLAIR, which provided the best total SNR (+74% and +49% compared to ihMT-RAGE in the white and gray matter, P <= 0.004). IhMTsat quantification was successful in all cases with strong correlation between all sequences (r(2) > 0.75). Early experiments showed potential for spinal cord imaging. Conclusions FSE generally offers higher SNR compared to gradient-echo based acquisitions for magnetization-prepared contrasts as illustrated here in the case of ihMT. However, physiological noise has a significant effect, but an inversion-recovery-based CSF suppression was shown to be efficient in mitigating effects of CSF motion.
引用
收藏
页码:550 / 564
页数:15
相关论文
共 50 条
  • [21] Optimization of magnetization-prepared rapid gradient echo (MP-RAGE) sequence for neonatal brain MRI
    Lili He
    Jinghua Wang
    Zhong-Lin Lu
    Beth M. Kline-Fath
    Nehal A. Parikh
    Pediatric Radiology, 2018, 48 : 1139 - 1151
  • [22] Parallel-transmission-enabled magnetization-prepared rapid gradient-echo T1-weighted imaging of the human brain at 7 T
    Cloos, M. A.
    Boulant, N.
    Luong, M.
    Ferrand, G.
    Giacomini, E.
    Hang, M. -F.
    Wiggins, C. J.
    Le Bihan, D.
    Amadon, A.
    NEUROIMAGE, 2012, 62 (03) : 2140 - 2150
  • [23] Normal structures in the intracranial dural sinuses: Delineation with 3D contrast-enhanced magnetization prepared rapid acquisition gradient-echo imaging sequence
    Liang, LX
    Korogi, Y
    Sugahara, T
    Ikushima, I
    Shigematsu, Y
    Takahashi, M
    Provenzale, JM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (10) : 1739 - 1746
  • [24] Detection of colorectal liver metastases with magnetization-prepared rapid acquisition gradient echo: Thinner slices, better performance?
    Pijl, ME
    Hoekstra, J
    Wasser, MN
    RADIOLOGY, 2002, 225 : 299 - 299
  • [25] MAGNETIZATION-PREPARED RAPID GRADIENT ECHO (MP-RAGE) MAGNETIC-RESONANCE-IMAGING OF MORGAGNIS HERNIA
    DELANGE, EE
    URBANSKI, SR
    MUGLER, JP
    BROOKEMAN, JR
    EUROPEAN JOURNAL OF RADIOLOGY, 1990, 11 (03) : 196 - 199
  • [26] Voxel-Based Morphometry of Progressive Supranuclear Palsy Using a 3D Fast Low-angle Shot Localizer Image: A Comparison with Magnetization-Prepared Rapid Gradient Echo
    Shang, Cong
    Inui, Shohei
    Kaneda, Daita
    Uchida, Yuto
    Toyama, Hiroshi
    Sakurai, Keita
    Hashizume, Yoshio
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2024,
  • [27] Association of Carotid Intraplaque Hemorrhage and Territorial Acute Infarction in Patients with Acute Neurological Symptoms Using Carotid Magnetization-Prepared Rapid Acquisition with Gradient-Echo
    Park, Jung Soo
    Kwak, Hyo Sung
    Lee, Jong Myong
    Koh, Eun Jeong
    Chung, Gyung Ho
    Hwang, Seung Bae
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2015, 57 (02) : 94 - 99
  • [28] Quantification of Carotid Intraplaque Hemorrhage: Comparison between Manual Segmentation and Semi-Automatic Segmentation on Magnetization-Prepared Rapid Acquisition with Gradient-Echo Sequences
    Song, Young Ju
    Kwak, Hyo Sung
    Chung, Gyung Ho
    Jo, Seongil
    DIAGNOSTICS, 2019, 9 (04)
  • [29] Carotid Magnetization-Prepared Rapid Acquisition With Gradient-Echo Signal Is Associated With Acute Territorial Cerebral Ischemic Events Detected by Diffusion-Weighted MRI
    McNally, J. Scott
    Kim, Seong-Eun
    Yoon, Hyo-Chun
    Findeiss, Laura K.
    Roberts, John A.
    Nightingale, Daniel R.
    Narra, Krishna K.
    Parker, Dennis L.
    Treiman, Gerald S.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (03) : 376 - 382
  • [30] Magnetization-prepared spoiled gradient-echo snapshot imaging for efficient measurement of R2-R1ρ in knee cartilage
    Han, Misung
    Tibrewala, Radhika
    Bahroos, Emma
    Pedoia, Valentina
    Majumdar, Sharmila
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (02) : 733 - 745