I-gel Plus acts as a superior conduit for fiberoptic intubation than standard i-gel

被引:2
|
作者
Chaki, Tomohiro [1 ]
Tachibana, Shunsuke [1 ]
Kumita, Sho [1 ]
Sato, Satoshi [1 ]
Hirahata, Tomoki [1 ]
Ikeshima, Yuta [1 ]
Ohsaki, Yuki [2 ]
Yamakage, Michiaki [1 ]
机构
[1] Sapporo Med Univ, Dept Anesthesiol, Sch Med, Sapporo, Hokkaido, Japan
[2] Sapporo Med Univ, Dept Anat 1, Sch Med, Sapporo, Hokkaido, Japan
关键词
LARYNGEAL MASK AIRWAY; SUPRAGLOTTIC AIRWAY; TRACHEAL INTUBATION; ENDOTRACHEAL INTUBATION; CADAVER; VENTILATION; I-GEL(TM); DEVICES; METAANALYSIS; PRESSURE;
D O I
10.1038/s41598-023-45631-0
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The supraglottic airway (SGA) is widely used. I-gel Plus is a next-generation i-gel with some improvements, including facilitation of fiberoptic tracheal intubation (FOI). To compare the performance of i-gel Plus and standard i-gel as conduits for FOI, a Thiel-embalmed cadaveric study was conducted. Twenty-two anesthesiologists were enrolled as operators in Experiment 1. The i-gel Plus and standard i-gel were inserted into one cadaver, and the FOI was performed through each SGA. The primary outcome was time required for FOI. The secondary outcomes were the number of attempts and visual analog scale (VAS) score for difficulty in FOI. Moreover, fiberoptic views of the vocal cords in each SGA were assessed by an attending anesthesiologist using nine cadavers in Experiment 2. The percentage of glottic opening (POGO) score without fiberscope tip upward flexion and upward angle of the fiberscope tip to obtain a 100% POGO score were evaluated as secondary outcomes. The time for FOI through i-gel Plus was significantly shorter than that through standard i-gel (median (IQR), i-gel Plus: 30.3 (25.4-39.0) s, vs standard i-gel: 54.7 (29.6-135.0) s; median of differences, 24.4 s; adjusted 95% confidence interval, 3.0-105.7; adjusted P=0.040). Although the number of attempts for successful FOI was not significantly different, the VAS score for difficulty in the i-gel Plus group was significantly lower (easier) than that in the standard i-gel group. Moreover, i-gel Plus required a significantly smaller upward angle of the fiberscope tip to obtain a 100% POGO score. FOI can be performed more easily using i-gel Plus than using standard i-gel because of the improved fiberoptic visibility of vocal cords.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Use of an i-gel™ for airway rescue
    Joshi, N. A.
    Baird, M.
    Cook, T. M.
    ANAESTHESIA, 2008, 63 (09) : 1020 - 1021
  • [22] Aspiration recognition with an i-gel airway
    Liew, G.
    John, B.
    Ahmed, S.
    ANAESTHESIA, 2008, 63 (07) : 786 - 786
  • [23] I-gel for Positive Pressure Ventilation
    Maharjan, Shyam Krishna
    JOURNAL OF NEPAL MEDICAL ASSOCIATION, 2013, 52 (05) : 255 - 259
  • [24] Is the i-gel supraglottic airway superior to the LMA® ProSeal in paediatric anaesthesia?
    Cumberworth, J.
    Cumberworth, A.
    ANAESTHESIA, 2015, 70 : 15 - 15
  • [25] Fiberoptic intubation through the i-gel™ vs. LMA Fastrach™ (ILMA) in patients with predicted difficult airway
    Theiler, Lorenz
    Graf, Thomas
    Urwyler, Natalie
    Luyet, Cedric
    Greif, Robert
    SWISS MEDICAL WEEKLY, 2009, 139 (41-42) : 19S - 19S
  • [26] Fiberoptic intubation through an I-Gel supraglottic airway in two patients with predicted difficult airway and intellectual disability
    Michalek, Pavel
    Hodgkinson, Philip
    Donaldson, William
    ANESTHESIA AND ANALGESIA, 2008, 106 (05): : 1501 - 1504
  • [27] I-gel supraglottic airway for rescue airway management and as a conduit for tracheal intubation in a patient with acute respiratory failure
    Campbell, J.
    Michalek, P.
    Deighan, M.
    RESUSCITATION, 2009, 80 (08) : 963 - 963
  • [28] TRACHEOTOMY GUIDED BY FIBEROPTIC BRONCHOSCOPY THROUGH AN I-GEL SUPRAGLOTTIC AIRWAY DEVICE
    Dominguez Garcia, D.
    Leon Sansegundo, T.
    Tejera Concepcion, R.
    Espinosa Dominguez, E.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2009, 56 (10): : 643 - 645
  • [29] Successful use of the I-gel supraglottic airway as a conduit for blind pre-hospital intubation during resuscitation
    Tiesmeier, J.
    Emmerich, M.
    RESUSCITATION, 2011, 82 (10) : 1358 - 1359
  • [30] A comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway: A manikin study
    Michalek, P.
    Donaldson, W.
    Graham, C.
    Hinds, J. D.
    RESUSCITATION, 2010, 81 (01) : 74 - 77