Comparison of ultrasound-guided femoral artery cannulation versus palpation technique in neonates undergoing cardiac surgery

被引:4
|
作者
Salik, Fikret [1 ]
Bicak, Mustafa [1 ]
机构
[1] Diyarbakir Gazi Yasargil Training & Res Hosp, Dept Anesthesiol & Reanimat, TR-21010 Diyarbakir, Kayapinar, Turkey
来源
JOURNAL OF VASCULAR ACCESS | 2023年 / 24卷 / 01期
关键词
Neonates; cardiac surgery; ultrasound; palpation; femoral artery cannulation; VASCULAR COMPLICATIONS; VEIN CATHETERIZATION; INFANTS; ACCESS; GUIDANCE; CHILDREN; RESIDENTS;
D O I
10.1177/11297298211023307
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives: Palpation technique for femoral artery cannulation can be very difficult, especially in neonates. In this study, we evaluated whether ultrasound-guided cannulation of the femoral artery is superior to palpation technique in neonates undergoing cardiac surgery. Methods: Forty neonates undergoing cardiac surgery were prospectively randomized into two groups (Ultrasound group and Palpation group). Access time, number of attempts, number of successful cannulations on first attempt, success rate, number of cannulas used, inadvertent access, and complications were compared between the two groups. Cost analyses of the cannulation were performed in two groups. Results: In the ultrasound group, access time for femoral artery cannulation was shorter (6.4 +/- 3.0 and 10.2 +/- 4.4, p = 0.003) and the number of attempts (1.4 +/- 0.6 and 2.3 +/- 0.8, p < 0.001) was lower compared to the palpation group. The number of successful cannulations on first-attempt (15 (75%) and 5 (25%), p = 0.002) and the success rate (95% (19) and 60% (12), p = 0.008) were higher in the ultrasound group. The number of cannulas used in the ultrasound group was less than the palpation group (p = 0.001). The cost of intervention was higher in the palpation group compared to the ultrasound group (p = 0.048). Conclusions: The ultrasound-guided cannulation of the femoral artery in neonates is superior to the palpation technique based on the increased of the number of successful first-attempt cannulation and success rate, and the reducing of the access time, number of attempts, number of cannulas used, and cost of cannulation.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 50 条
  • [31] ULTRASOUND GUIDED CANNULATION OF FEMORAL ARTERY IN PATIENTS UNDERGOING TRANSCATHETER AORTIC VALVE REPLACEMENT
    Di Costanzo, Assunta
    Sorrentino, Sabato
    Panarello, Alessandra
    Spinali, Martina
    Bellantoni, Antonio
    Boccuto, Fabiola
    Mariani, Andrea
    Manzo, Rachele
    Molaro, Maddalena Immobile
    Polimeni, Alberto
    Spaccarotella, Carmen
    Mongiardo, Annalisa
    Esposito, Giovanni
    Indolfi, Ciro
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2022, 24
  • [32] Reflections on: "Comparison of in-plane versus out-of-plane ultrasound-guided radial artery cannulation"
    Sethuraman, Raghuraman
    SRI LANKAN JOURNAL OF ANAESTHESIOLOGY, 2025, 33 (01): : 12 - 13
  • [33] Ultrasound-guided antegrade femoral access: comparison between the common femoral artery and the superficial femoral artery
    Gutzeit, A.
    Graf, N.
    Schoch, E.
    Sautter, T.
    Jenelten, R.
    Binkert, C. A.
    EUROPEAN RADIOLOGY, 2011, 21 (06) : 1323 - 1328
  • [34] Ultrasound-guided antegrade femoral access: comparison between the common femoral artery and the superficial femoral artery
    A. Gutzeit
    N. Graf
    E. Schoch
    T. Sautter
    R. Jenelten
    C. A. Binkert
    European Radiology, 2011, 21 : 1323 - 1328
  • [35] Evaluation of ultrasound-guided radial artery cannulation in children
    Ganesh, Arjunan
    Kaye, Robin
    Cahill, Anne Marie
    Stern, Whitney
    Pachikara, Reshma
    Gallagher, Paul R.
    Watcha, Mehernoor
    Pediatric Critical Care Medicine, 2009, 10 (01) : 45 - 48
  • [36] Ultrasound-guided cannulation of the femoral vein for acute haemodialysis access
    Kwon, TH
    Kim, YL
    Cho, DK
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1997, 12 (05) : 1009 - 1012
  • [37] Ultrasound-guided peripheral artery cannulation: A priority, not an option
    Sokhal, Navdeep
    Khandelwal, Ankur
    Sokhal, Suman
    Chaturvedi, Arvind
    INDIAN JOURNAL OF ANAESTHESIA, 2020, 64 (02) : 167 - 168
  • [38] Ultrasound-Guided Dynamic Needle Tip Positioning Technique Versus Palpation Technique for Radial Arterial Cannulation in Adult Surgical Patients: A Randomized Controlled Trial
    Kiberenge, Roy K.
    Ueda, Kenichi
    Rosauer, Brett
    ANESTHESIA AND ANALGESIA, 2018, 126 (01): : 120 - 126
  • [39] "Evidence" for Ultrasound-Guided Femoral Vein Cannulation in Infants and Children?
    Pivalizza, Evan G.
    Maposa, Douglas
    ANESTHESIA AND ANALGESIA, 2011, 112 (04): : 991 - 992
  • [40] Comparison of Ultrasound-Guided Versus Palpatory Method of Posterior Tibial Artery Cannulation: A Prospective Randomized Controlled Study
    Eda, Jhansi
    Gupta, Priyanka
    Kaushal, Ashutosh
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (12)