Comparison of ultrasound-guided femoral artery cannulation versus palpation technique in neonates undergoing cardiac surgery

被引:4
|
作者
Salik, Fikret [1 ]
Bicak, Mustafa [1 ]
机构
[1] Diyarbakir Gazi Yasargil Training & Res Hosp, Dept Anesthesiol & Reanimat, TR-21010 Diyarbakir, Kayapinar, Turkey
来源
JOURNAL OF VASCULAR ACCESS | 2023年 / 24卷 / 01期
关键词
Neonates; cardiac surgery; ultrasound; palpation; femoral artery cannulation; VASCULAR COMPLICATIONS; VEIN CATHETERIZATION; INFANTS; ACCESS; GUIDANCE; CHILDREN; RESIDENTS;
D O I
10.1177/11297298211023307
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives: Palpation technique for femoral artery cannulation can be very difficult, especially in neonates. In this study, we evaluated whether ultrasound-guided cannulation of the femoral artery is superior to palpation technique in neonates undergoing cardiac surgery. Methods: Forty neonates undergoing cardiac surgery were prospectively randomized into two groups (Ultrasound group and Palpation group). Access time, number of attempts, number of successful cannulations on first attempt, success rate, number of cannulas used, inadvertent access, and complications were compared between the two groups. Cost analyses of the cannulation were performed in two groups. Results: In the ultrasound group, access time for femoral artery cannulation was shorter (6.4 +/- 3.0 and 10.2 +/- 4.4, p = 0.003) and the number of attempts (1.4 +/- 0.6 and 2.3 +/- 0.8, p < 0.001) was lower compared to the palpation group. The number of successful cannulations on first-attempt (15 (75%) and 5 (25%), p = 0.002) and the success rate (95% (19) and 60% (12), p = 0.008) were higher in the ultrasound group. The number of cannulas used in the ultrasound group was less than the palpation group (p = 0.001). The cost of intervention was higher in the palpation group compared to the ultrasound group (p = 0.048). Conclusions: The ultrasound-guided cannulation of the femoral artery in neonates is superior to the palpation technique based on the increased of the number of successful first-attempt cannulation and success rate, and the reducing of the access time, number of attempts, number of cannulas used, and cost of cannulation.
引用
收藏
页码:27 / 34
页数:8
相关论文
共 50 条
  • [1] Femoral arterial cannulation performed by residents: a comparison between ultrasound-guided and palpation technique in infants and children undergoing cardiac surgery
    Siddik-Sayyid, Sahar M.
    Aouad, Marie T.
    Ibrahim, Muhammad H.
    Taha, Samar K.
    Nawfal, Maud F.
    Tfaili, Youssef J.
    Kaddoum, Roland N.
    PEDIATRIC ANESTHESIA, 2016, 26 (08) : 823 - 830
  • [2] COMPARISON OF ULTRASOUND-GUIDED VERSUS FLUOROSCOPY-GUIDED ACCESS IN FEMORAL ARTERY CANNULATION FOR CARDIAC PROCEDURES
    Shoemaker, Emma
    Tangri, Apoorva
    Vaz, Igor
    Agarwal, Khushboo
    Silberman, Herschl B.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 1458 - 1458
  • [3] Comparison of ultrasound guidance and palpation technique for femoral artery catheterization in children undergoing cardiac surgery
    Aktiz-Bicak, Esra
    Kilic, Yigit
    Elmastas, Deniz
    Bicak, Mustafa
    Aldudak, Bedri
    Salik, Fikret
    CIRUGIA Y CIRUJANOS, 2023, 91 (05): : 633 - 640
  • [4] Femoral Vein Cannulation Performed by Residents: A Comparison Between Ultrasound-Guided and Landmark Technique in Infants and Children Undergoing Cardiac Surgery
    Aouad, Marie T.
    Kanazi, Ghassan E.
    Abdallah, Faraj W.
    Moukaddem, Farah H.
    Turbay, Massud J.
    Obeid, Mounir Y.
    Siddik-Sayyid, Sahar M.
    ANESTHESIA AND ANALGESIA, 2010, 111 (03): : 724 - 728
  • [5] Ultrasound-Guided Femoral Arterial Cannulation in Neonates Undergoing Cardiac Surgery or Catheterization: Comparison of 0.014-Inch Floppy Versus 0.019-Inch Straight Guidewire
    Polat, Tugcin Bora
    PEDIATRIC CRITICAL CARE MEDICINE, 2019, 20 (07) : 608 - 613
  • [6] A comparison of the success rate of radial artery cannulation between the ultrasound-guided and conventional palpation techniques in elderly patients undergoing cardiothoracic surgery
    Chanthawong, Sarinya
    Tribuddharat, Sirirat
    Sathitkarnmanee, Thepakorn
    Suwongkrua, Thanaporn
    Silarat, Suparit
    Plengpanich, Pathawat
    ANNALS OF CARDIAC ANAESTHESIA, 2022, 25 (04) : 447 - 452
  • [7] Ultrasound-guided arterial cannulation: Is the game over for the palpation technique?
    Blanco, Pablo
    MEDICINA INTENSIVA, 2023, 47 (07) : 371 - 372
  • [8] A randomized comparison of ultrasound guided versus direct palpation method of radial artery cannulation techniques in adult patients undergoing open heart surgery
    Nasreen, Amina
    Khuwaja, Amin M.
    Akhtar, Parveen
    Amjad, Najma
    Rao, Zahid Akhtar
    ANAESTHESIA PAIN & INTENSIVE CARE, 2016, 20 (01) : 38 - 42
  • [9] Ultrasound-Guided Artery Cannulation Technique Versus Palpation Technique in Adult Patients in Pre-Anesthesia Room: A Randomized Controlled Trial
    Yu, Yongqi
    Lu, Xueying
    Fang, Weiping
    Liu, Xuesheng
    Lu, Yao
    MEDICAL SCIENCE MONITOR, 2019, 25 : 7306 - 7311
  • [10] COMPARISON OF THE ARTERIAL AND CENTRAL VENOUS CANNULATION IN PALPATION AND ULTRASOUND-GUIDED TECHNIQUES
    Tirnava, A.
    Bakal, O.
    Yedekci, A. E.
    Inangil, G.
    Deniz, S.
    Ozkan, S.
    Sen, H.
    ANESTHESIA AND ANALGESIA, 2016, 123 : 63 - 63