Effect of Headed Stud Thickness Embedded in Steel Fiber Concrete on Pull-Out Strength

被引:2
|
作者
Nzambi, Aaron Kadima Lukanu Lwa [1 ]
de Oliveira, Denio Ramam Carvalho [1 ]
Moraes, Heber Dioney Sousa [1 ]
机构
[1] Fed Univ Para, Dept Civil Engn, 01 Augusto Correa St,Campus Univ Guama, BR-66075110 Belem, Para, Brazil
关键词
Anchorages; Codes of practice and standards; Design methods; Headed stud thickness; Pull-out test; Steel fiber concrete; CAPACITY; BEHAVIOR; ANCHORS;
D O I
10.1061/PPSCFX.SCENG-1435
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental study on the behavior of the load capacity of handcrafted studs symmetrically embedded in concrete reinforced with steel fiber. A total of eight blocks were subjected to pull-out tests. The main variables were stud head thickness (3.17, 4.76, 6.35, and 7.9 mm) and concrete type. The results showed no significant difference in the mean pull-out strength in both types of concrete mixtures: conventional and fibrous. Therefore, the effect of steel fiber addition tends to reduce the inclination plane of cracks, changing the mode of abrupt failure to more ductile. Moreover, in conventional concrete, the thickness th=7.93 mm (0.20 dh) lost about 15% of the pull-out strength compared to the thickness th=3.17 mm (0.08 dh); in contrast, it obtained a gain of 5% in concrete with the steel fiber. That is, a thickness of approximately 10% of the head diameter can adequately provide satisfactory results in embedment with or without the addition of the steel fiber for fc=35 MPa. In addition, the literature models were more conservative. Also, a modified concrete capacity design method was proposed, considering the head thickness and the empirical factor for concrete breakout strength adjustment, k=20. The results were satisfactory, with an average of 1.00 and a coefficient of variation of only 6% in steel fiber concrete.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Pull-out tests of ribbed steel reinforcing bars embedded in concrete with steel fibres
    Lukanu Lwa Nzambi, Aaron Kadima
    Carvalho de Oliveira, Denio Ramam
    de Oliveira, Andrielli Morais
    Picanco, Marcelo de Souza
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2021, 174 (03) : 181 - 189
  • [12] Effect of pull-out rate on interfacial bonding strength of fiber
    Pan, Zhiyuan
    Liu, Xiang
    ENVIRONMENTAL PROTECTION AND RESOURCES EXPLOITATION, PTS 1-3, 2013, 807-809 : 2831 - 2835
  • [13] Headed studs close to the concrete edge under pull-out
    Pascual, A. M.
    Kuhlmann, U.
    Ruopp, J.
    Stempniewski, L.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 435 - 440
  • [14] Pull-out failure of headed studs close to the concrete edge
    Stempniewski, Lena
    Kuhlmann, Ulrike
    ce/papers, 2019, 3 (3-4) : 237 - 242
  • [15] MODEL FOR PULL-OUT STRENGTH OF ANCHORS IN CONCRETE
    PEIER, WH
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1983, 109 (05): : 1155 - 1173
  • [16] Pull-out behavior of steel fiber embedded in flowable RPC and ordinary mortar
    Beglarigale, Ahsanollah
    Yazici, Halit
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 75 : 255 - 265
  • [17] Confinement effects on the steel-concrete bond strength and pull-out failure
    Torre-Casanova, A.
    Jason, L.
    Davenne, L.
    Pinelli, X.
    ENGINEERING FRACTURE MECHANICS, 2013, 97 : 92 - 104
  • [18] Experimental and numerical analysis pull-out strength of steel strip in foam concrete
    Ramezani, Maziar
    Vilches, Juan
    Neitzert, Thomas
    EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2013, 17 (10) : 982 - 1001
  • [19] PULL-OUT BEHAVIOUR OF EMBEDDED BLIND BOLTS IN CONCRETE-FILLED STEEL TUBES
    Xu, Fei
    Chan, Tak-Ming
    Young, Ben
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 1097 - 1106
  • [20] Pull-out of axisymmetric headed anchors
    Karihaloo, BL