Identification of Atrial Fibrillation With Single-Lead Mobile ECG During Normal Sinus Rhythm Using Deep Learning

被引:0
|
作者
Kim, Jiwoong [1 ,2 ]
Lee, Sun Jung [3 ]
Ko, Bonggyun [1 ,4 ]
Lee, Myungeun [2 ,5 ]
Lee, Young-Shin [3 ]
Lee, Ki Hong [2 ,5 ,6 ]
机构
[1] Chonnam Natl Univ, Dept Math & Stat, Gwangju, South Korea
[2] Chonnam Natl Univ Hosp, Dept Cardiovasc Med, Gwangju, South Korea
[3] Seers Technol Co Ltd, 291-13 Dongbu Daero, Pyeongtaek 17707, South Korea
[4] XRAI, Gwangju, South Korea
[5] Chonnam Natl Univ, Med Sch, Dept Internal Med, Gwangju, South Korea
[6] Chonnam Natl Univ Hosp, Heart Ctr, Dept Cardiovasc Med, 42 Jebong Ro, Gwangju 61469, South Korea
基金
新加坡国家研究基金会;
关键词
Artificial Intelligence; Atrial Fibrillation; Electrocardiography; Mobile Applications; Probability Learning; RECURRENT NEURAL-NETWORKS; CRYPTOGENIC STROKE; WEARABLE DEVICES; ACCURACY; ABLATION;
D O I
10.3346/jkms.2024.39.e56
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The acquisition of single-lead electrocardiogram (ECG) from mobile devices offers a more practical approach to arrhythmia detection. Using artificial intelligence for atrial fibrillation (AF) identification enhances screening efficiency. However, the potential of singlelead ECG for AF identification during normal sinus rhythm (NSR) remains under-explored. This study introduces a method to identify AF using single-lead mobile ECG during NSR. Methods: We employed three deep learning models: recurrent neural network (RNN), long short-term memory (LSTM), and residual neural networks (ResNet50). From a dataset comprising 13,509 ECGs from 6,719 patients, 10,287 NSR ECGs from 5,170 patients were selected. Single-lead mobile ECGs underwent noise filtering and segmentation into 10-second intervals. A random under-sampling was applied to reduce bias from data imbalance. The final analysis involved 31,767 ECG segments, including 15,157 labeled as masked AF and 16,610 as Healthy. Results: ResNet50 outperformed the other models, achieving a recall of 79.3%, precision of 65.8%, F1-score of 71.9%, accuracy of 70.5%, and an area under the receiver operating characteristic curve (AUC) of 0.79 in identifying AF from NSR ECGs. Comparative performance scores for RNN and LSTM were 0.75 and 0.74, respectively. In an external validation set, ResNet50 attained an F1-score of 64.1%, recall of 68.9%, precision of 60.0%, accuracy of 63.4%, and AUC of 0.68. Conclusion: The deep learning model using single-lead mobile ECG during NSR effectively identified AF at risk in future. However, further research is needed to enhance the performance of deep learning models for clinical application.
引用
下载
收藏
页数:12
相关论文
共 50 条
  • [21] Six-lead device superior to single-lead smartwatch ECG in atrial fibrillation detection
    Scholten, Josca
    Jansen, Ward P. J.
    Horsthuis, Thomas
    Mahes, Anuska D.
    Winter, Michiel M.
    Zwinderman, Aeilko H.
    Keijer, Jan T.
    Minneboo, Madelon
    de Groot, Joris R.
    Bokma, Jouke P.
    AMERICAN HEART JOURNAL, 2022, 253 : 53 - 58
  • [22] Screening for Atrial Fibrillation Using a Mobile, Single-Lead Electrocardiogram in Canadian Primary Care Clinics
    Godin, Richard
    Yeung, Cynthia
    Baranchuk, Adrian
    Guerra, Peter
    Healey, Jeff S.
    CANADIAN JOURNAL OF CARDIOLOGY, 2019, 35 (07) : 840 - 845
  • [23] Comparison of adhesive single-lead ECG device and Holter test for atrial fibrillation monitoring
    Kwon, S.
    Lee, S. R.
    Choi, E. K.
    Ahn, H. J.
    Song, H. S.
    Lee, Y. S.
    EUROPEAN HEART JOURNAL, 2022, 43 : 414 - 414
  • [24] Effectiveness of single-lead ECG devices for detecting atrial fibrillation: An overview of systematic reviews
    Gu, Hai Yue
    Huang, Jun
    Liu, Xu
    Qiao, Shu Qian
    Cao, Xi
    WORLDVIEWS ON EVIDENCE-BASED NURSING, 2024, 21 (01) : 79 - 86
  • [25] Demo Abstract: Atrial Fibrillation Burden Computation from Single-Lead ECG on Device
    Sharma, Varsha
    Ghose, Avik
    PROCEEDINGS OF THE 21ST ACM CONFERENCE ON EMBEDDED NETWORKED SENSOR SYSTEMS, SENSYS 2023, 2023, : 494 - 495
  • [26] Reply to "The role of single-lead ECG in screening for atrial fibrillation deserves more attention"
    Karregat, Evert P. M.
    Lucassen, Wim A. M.
    Stoffers, Henri E. J. H.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2022, 348 : 74 - 74
  • [27] An artificial intelligence-based model for prediction of atrial fibrillation from single-lead sinus rhythm electrocardiograms facilitating screening
    Hygrell, Tove
    Viberg, Fredrik
    Dahlberg, Erik
    Charlton, Peter H.
    Gudmundsdottir, Katrin Kemp
    Mant, Jonathan
    Hornlund, Josef Lindman
    Svennberg, Emma
    EUROPACE, 2023, 25 (04): : 1332 - 1338
  • [28] DIGITALIS TOLERANCE DURING ATRIAL-FIBRILLATION AND NORMAL SINUS RHYTHM
    HISHIMOT.Y
    NAKAMURA, M
    MISHINA, Y
    TANAKA, T
    KIMURA, S
    KUNISHIG.H
    MATSUURA, T
    MARUMOTO, S
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1972, 36 (10): : 1117 - 1118
  • [29] Is atrial lead implantation during atrial fibrillation as efficient as after restitution of sinus rhythm?
    Wiegand, UKH
    Bode, F
    Bonnemeier, H
    Tölg, R
    Peters, W
    Katus, HA
    EUROPEAN HEART JOURNAL, 2000, 21 : 195 - 195
  • [30] Is atrial lead implantation during atrial fibrillation as efficient as after restitution of sinus rhythm?
    Wiegand, UKH
    Rode, F
    Bonnemeier, H
    Tölg, R
    Peters, W
    Katus, HA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 108A - 108A