Reliability and Concurrent Validity of Smartphone Clinometer Application for Measuring Scapular Rotations in Subjects With and Without Shoulder Pain

被引:0
|
作者
Kaur, Varmeet [1 ]
Makhija, Meena [1 ]
Phadke, Vandana [2 ]
机构
[1] Inst Rehabil Sci, Indian Spinal Injuries Ctr, New Delhi, India
[2] Indian Spinal Injuries Ctr, Dept Res, New Delhi, India
关键词
shoulder complex; measurement properties; psychometric; biomechanics; MOTION; AGREEMENT;
D O I
10.1123/jsr.2023-0005
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Context: Clinical assessment of scapular motion is obscured by a lack of clinically accessible and feasible angular measurement tools. This study evaluates the reliability and validity of the smartphone "Clinometer" app in measuring scapular upward rotation (UR) and anteroposterior tilt. Design: Psychometric analysis. Methods: We recruited 57 participants-10 with and 47 without shoulder pain. Two physical therapists consecutively measured both scapular movements using the Clinometer app at the arm by the side (rest), 30 degrees, 60 degrees, 90 degrees, and 120 degrees of humeral elevation in the scapular plane; one therapist measured again after 2 days. For evaluating concurrent validity, we compared the Clinometer scores with those measured using an electromagnetic motion capture system in 10 healthy participants. Intraclass correlation coefficients (ICC) with standard error of measurement (SEM) and minimal detectable difference at 90% confidence intervals (MDD90) were calculated. Concurrent validity was evaluated using repeated-measures analysis of variance followed by post hoc testing with Tukey-Kramer test (P <.05). Results: We observed good intrarater reliability (ICC: UR =.76-.85, tilt =.69-.9; SEM: 2.2 degrees-3.5 degrees; MDD90: similar to 5 degrees-8 degrees) and moderate to good interrater reliability (ICC: UR =.66-.78, tilt =.66-.76; SEM: 3.6 degrees-8 degrees; MDD90: similar to 9 degrees- 18 degrees) for both rotations. The Clinometer scores for UR were comparable to electromagnetic motion capture system at all angles except 90 degrees (difference similar to 8 degrees); for scapular tilt, the scores were comparable only at rest and 30 degrees elevation. Conclusion: The Clinometer app is reliable and valid for measuring scapular UR throughout and for scapular tilt at lower humeral elevation angles. The MDD90 values for scapular rotations computed in this study can be helpful in rehabilitation planning and future research.
引用
收藏
页码:926 / 931
页数:6
相关论文
共 42 条
  • [21] Reliability and concurrent validity of a new iPhone® goniometric application for measuring active wrist range of motion: a cross-sectional study in asymptomatic subjects
    Pourahmadi, Mohammad Reza
    Takamjani, Ismail Ebrahimi
    Sarrafzadeh, Javad
    Bahramian, Mehrdad
    Mohseni-Bandpei, Mohammad Ali
    Rajabzadeh, Fatemeh
    Taghipour, Morteza
    JOURNAL OF ANATOMY, 2017, 230 (03) : 484 - 495
  • [22] THE CONCURRENT VALIDITY AND RELIABILITY OF THE SMARTPHONE MEASUREMENT APPLICATION TO EVALUATE ILIOTIBIAL BAND TIGHTNESS: A CROSS-SECTIONAL STUDY
    Unuvar, Bayram Sonmez
    Gercek, Hasan
    Demirdel, Ertugrul
    JOURNAL OF BASIC AND CLINICAL HEALTH SCIENCES, 2024, 8 (02): : 349 - 357
  • [23] Scapular Motor Control and Upper Limb Movement Quality in Subjects with and without Chronic Shoulder Pain: A Cross-Sectional Study
    Melo, Ana S. C.
    Guedes, Diana C.
    Matias, Ricardo
    Cruz, Eduardo B.
    Vilas-Boas, J. Paulo
    Sousa, Andreia S. P.
    APPLIED SCIENCES-BASEL, 2024, 14 (08):
  • [24] The reliability and concurrent validity of a new iPhone® application for measuring active lumbar spine flexion and extension range of motion in patients with low back pain
    Pourahmadi, Mohammadreza
    Momeni, Elnaz
    Mohseni, Negar
    Hesarikia, Hamid
    Ghanjal, Ali
    Shamsoddini, Alireza
    PHYSIOTHERAPY THEORY AND PRACTICE, 2021, 37 (01) : 204 - 217
  • [25] Evaluation of a smartphone accelerometer system for measuring nonlinear dynamics during treadmill walking: Concurrent validity and test-retest reliability
    Di Bacco, Vincenzo E.
    Gage, William H.
    JOURNAL OF BIOMECHANICS, 2023, 151
  • [26] Scapular Retraction under Adduction Load: An Alternative to Overhead Exercises to Activate Infraspinatus, Upper, and Lower Trapezius in Subjects with and without Shoulder Pain
    dos Santos, Jefferson James
    Nagy, Rebeca Orozco
    Souza, Matheus Almeida
    Intelangelo, Leonardo
    Barbosa, Michelle Almeida
    Silveira-Nunes, Gabriela
    Barbosa, Alexandre Carvalho
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (17)
  • [27] VALIDITY AND RELIABILITY OF A SMARTPHONE GONIOMETER APPLICATION FOR MEASURING HIP RANGE OF MOTION IN PATIENTS WITH HIP OSTEOARTHRITIS: A PILOT STUDY
    Sarac, D. C.
    Yalcinkaya, G.
    Unver, B.
    ANNALS OF THE RHEUMATIC DISEASES, 2017, 76 : 1531 - 1531
  • [28] Reliability and validity of a smartphone goniometer application for measuring the quadriceps angle in healthy women: a cross-sectional study
    Aafreen, Aafreen
    Khan, Ashfaque
    Khan, Abdur Raheem
    Ahmad, Ausaf
    Parween, Saba
    Maurya, Neeraj Kumar
    Alshehri, Mohammed M.
    Abu Shaphe, Mohammad
    Ahmed, Hashim
    Mirza, Hadia
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2024, 31 (02):
  • [29] Shoulder and elbow joint position sense assessment using a mobile app in subjects with and without shoulder pain - between-days reliability
    Ramos, Marieli M.
    Carnaz, Leticia
    Mattiello, Stela M.
    Karduna, Andrew R.
    Zanca, Gisele G.
    PHYSICAL THERAPY IN SPORT, 2019, 37 : 157 - 163
  • [30] Reliability and concurrent validity of a mobile application to measure thoracolumbar range of motion in low back pain patients
    Macedo, Liane de Brito
    Borges, Daniel Tezoni
    Melo, Samara Alencar
    Aires da Costa, Karinna Sonalya
    Sousa, Catarina de Oliveira
    Brasileiro, Jamilson Simoes
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2020, 33 (01) : 145 - 151