Performance assessment of the evaporator tubes of a natural circulation boiler by different two-phase flow models

被引:2
|
作者
Hossain, Md Naim [1 ]
Ghosh, Koushik [2 ]
Manna, Nirmal K. [2 ]
机构
[1] Jalpaiguri Govt Engn Coll, Dept Mech Engn, Jalpaiguri, WB, India
[2] Jadavpur Univ, Dept Mech Engn, Kolkata, India
关键词
Thermosyphon; Two-phase flow; CHF; Circulation ratio; Boiler design; Naturally assisted boiler; DRIFT-FLUX MODEL; HEAT-TRANSFER; DIAMETER; SEPARATION; FRACTION; SYSTEM; RATES;
D O I
10.1007/s40430-023-04354-z
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The objective of the present work is to evaluate the performance of the evaporator tubes of a natural circulation boiler under different operating pressure and heat flux. A significant concern of the present work is assessing the dry-out/critical heat flux limit and the critical circulation ratio (CR) of an existing evaporator downcomer system of a natural circulation boiler. The analysis of these parameters is crucial from a safe operation perspective. To carry out the study, three two-phase flow models, namely homogeneous flow model (HFM), separated flow model (SFM), and drift-flux model (DFM), are developed. The sensitivity of the models on various thermo-hydraulic parameters, change of flow regime, and circulation ratio is assessed. A rigorous validation exercise is carried out for a host of experimental, numerical, and plant design data pertaining to two-phase flow thermosyphon. The results indicate that the safe circulation ratio at low (< 40 bar) and intermediate (40-80 bar) pressure predicted by HFM is relatively high and differs substantially from the two other models. However, beyond 80 bar pressure (high operating pressure), the CR predicted by different models is considerably less and in closer agreement with each other. The practical boiler performance studies with different capacities indicate that the maximum difference of critical heat flux predicted by different models for boilers of different capacities lies within a 15% margin. These data will help the engineers associated with boiler operation and the associated persons with the boiler design sector.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Theoretical study on criteria of natural circulation two-phase flow instability
    Wu, JM
    ENERGY AND ENVIRONMENT, 1998, : 607 - 612
  • [22] Study on flow characteristics in an open two-phase natural circulation loop
    Yan, Xiao
    Fan, Guangming
    Sun, Zhongning
    ANNALS OF NUCLEAR ENERGY, 2017, 104 : 291 - 300
  • [23] Experimental study on two-phase natural circulation and flow termination in a loop
    Hsu, JT
    Ishii, M
    Hibiki, T
    NUCLEAR ENGINEERING AND DESIGN, 1998, 186 (03) : 395 - 409
  • [24] Effect of steam quality on two-phase flow in a natural circulation loop
    贾海军
    吴少融
    王宁
    姚思民
    Nuclear Science and Techniques, 1996, (02) : 81 - 84
  • [25] Effect of steam quality on two-phase flow in a natural circulation loop
    Jia, Hai-Jun
    Wu, Shao-Rong
    Wang, Ning
    Yao, Si-Min
    Nuclear Science and Techniques/Hewuli, 1996, 7 (02): : 81 - 84
  • [26] A comprehensive assessment of correlations for two-phase flow through Venturi tubes
    Liu, Xiaolei
    Lao, Liyun
    Falcone, Gioia
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2020, 78
  • [27] Theoretical analysis of two-phase flow in CPL evaporator
    2000, Zhejiang Univ, China (34):
  • [28] Steady-state performance of a two-phase natural circulation loop
    Rao, N. M.
    Sekhar, Ch. Chandra
    Maiti, B.
    Das, P. K.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2006, 33 (08) : 1042 - 1052
  • [29] Scaling evaluation of the two-phase natural circulation
    Wang, Han
    Li, Yuquan
    PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING AND THE ASME 2012 POWER CONFERENCE - 2012, VOL 3, 2012, : 191 - 195
  • [30] Cryogenic two-phase natural circulation loop
    Baek, Seungwhan
    Jung, Youngsuk
    Cho, Kiejoo
    CRYOGENICS, 2020, 111 (111)