New perspectives for the therapeutic drug monitoring of tacrolimus: Quantification in volumetric DBS based on an automated extraction and LC-MS/MS analysis

被引:6
|
作者
Rose, Gauthier [1 ]
Tafzi, Naima [1 ]
El Balkhi, Souleiman [1 ,2 ,3 ]
Rerolle, Jean-philippe [2 ,3 ,4 ]
Debette-Gratien, Marilyne [2 ,3 ,5 ]
Marquet, Pierre [1 ,2 ,3 ]
Saint-Marcoux, Franck [1 ,2 ,3 ]
Monchaud, Caroline [1 ,2 ,3 ,6 ]
机构
[1] CHU Limoges, Serv Pharmacol toxicol & pharmacovigilance, Limoges, France
[2] Univ Limoges, SERM UMR 1248 Pharmacol & Transplantat, Limoges, France
[3] FHU SUPORT, Limoges, France
[4] CHU Limoges, Serv Nephrol dialyse & transplantat, Limoges, France
[5] CHU Limoges, Serv Hepato gastroenterol & Nutr, Limoges, France
[6] CHU Limoges, Serv pharmacol toxicol & pharmacovigilance, INSERM UMR 1248, Ctr Biol & Rech Sante, 1248, 2 Ave Martin Luther King, F-87042 Limoges, France
关键词
Tacrolimus; Therapeutic drug monitoring; Volumetric dried blood spots; LC-MS/MS; Automated extraction; CYCLOSPORINE-A; BLOOD; HEMATOCRIT; CAPILLARY;
D O I
10.1016/j.jchromb.2023.123721
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Volumetric microsampling devices have been developed for home-based capillary blood sampling and are now increasingly proposed for the therapeutic drug monitoring (TDM) of immunosuppressive drugs. Our objective was to validate a LC-MS/MS method for tacrolimus quantification based on both a manual and an automated extraction of dried blood spots (DBS) collected with a volumetric microsampling device. DBS collection was performed by placing a drop of whole blood (WB) pre-spiked with tacrolimus onto a sealing film and placing the hemaPEN (R) device (Trajan Scientific and Medical, Melbourne, Australia) into the drop according to the device specifications. Tacrolimus was quantified using a fully automatic preparation module connected to a LCMS system (CLAM-3020 (R) and LCMS-8060 (R), Shimadzu, Marne-la-Vallee, France). The method was validated analytically and clinically in accordance with the EMA and IATDMCT guidelines. The method was linear from 1 to 100 mu g/L. Within-and between-run accuracy and precision fulfilled the validation criteria (biases and imprecision <15% or 20% for the lower limit of quantification). No hematocrit effect, matrix effect or carry-over was observed. No selectivity issue was identified and dilution integrity was confirmed. Tacrolimus in DBS was stable for 14 days at room temperature and +4 degrees C, and for 72h at +60 degrees C. There was a good correlation between tacrolimus concentrations measured in WB and in DBS of 20 kidney and liver transplant recipients (r=0.93 and 0.87, for manual and automated extraction respectively). A method for tacrolimus measurement in DBS collected with volumetric micro-sampling device, based on a fully automated process from pre-treatment to LC-MS/MS analysis was developed and validated according to analytical and clinical criteria. This performing sampling and analytical procedure opens the perspective of an easier, faster and more efficient TDM of tacrolimus for patients, clinicians and laboratories.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Therapeutic drug monitoring of polymyxin B by LC-MS/MS in plasma and urine
    Liu, Xiaofen
    Yu, Zhenwei
    Wang, Yu
    Wu, Hailan
    Bian, Xingchen
    Li, Xin
    Fan, Yaxin
    Guo, Beining
    Zhang, Jing
    BIOANALYSIS, 2020, 12 (12) : 845 - 855
  • [22] Bioanalytical LC-MS/MS validation of therapeutic drug monitoring assays in oncology
    van Nuland, Merel
    Rosing, Hilde
    Schellens, Jan H. M.
    Beijnen, Jos H.
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (01)
  • [23] A Simple and Rapid LC-MS/MS Method for Therapeutic Drug Monitoring of Lenalidomide
    Nesetoglu, Neset
    Kaplan, Cem
    Aslan, Serap Saglik
    Unal, Durisehvar Ozer
    PAKISTAN JOURNAL OF ANALYTICAL & ENVIRONMENTAL CHEMISTRY, 2020, 21 (01) : 19 - 26
  • [24] Some thoughts on the links between LC-MS/MS and therapeutic drug monitoring
    Saint-Marcoux, Franck
    ANNALES DE BIOLOGIE CLINIQUE, 2015, 73 (01) : 49 - 53
  • [25] A rapid, simple and sensitive LC-MS/MS method for lenvatinib quantification in human plasma for therapeutic drug monitoring
    Zanchetta, Martina
    Iacuzzi, Valentina
    Posocco, Bianca
    Bortolin, Giorgia
    Poetto, Ariana Soledad
    Orleni, Marco
    Canil, Giovanni
    Guardascione, Michela
    Foltran, Luisa
    Fanotto, Valentina
    Puglisi, Fabio
    Gagno, Sara
    Toffoli, Giuseppe
    PLOS ONE, 2021, 16 (10):
  • [26] An LC-MS/MS Method for Absolute Quantification of Nivolumab in Human Plasma: Application to Clinical Therapeutic Drug Monitoring
    Irie, Kei
    Okada, Akira
    Yamasaki, Yuta
    Kokan, Chiyuki
    Hata, Akito
    Kaji, Reiko
    Fukushima, Keizo
    Sugioka, Nobuyuki
    Okada, Yutaka
    Katakami, Nobuyuki
    Fukushima, Shoji
    THERAPEUTIC DRUG MONITORING, 2018, 40 (06) : 716 - 724
  • [27] QUANTIFICATION OF PHENOBARBITAL IN HUMAN PLASMA BY LC/MS/MS FOR THERAPEUTIC DRUG MONITORING
    Vlase, Laurian
    Felecan, Ioana
    Muntean, Dana
    Iacob, Daniela
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2010, 55 (01): : 15 - 21
  • [28] Ultra-fast LC-MS/MS in therapeutic drug monitoring: Quantification of clozapine and norclozapine in human plasma
    Couchman, Lewis
    Fisher, Danielle S.
    Subramaniam, Krithika
    Handley, Simon A.
    Boughtflower, Robert J.
    Benton, Christopher M.
    Flanagan, Robert J.
    DRUG TESTING AND ANALYSIS, 2018, 10 (02) : 323 - 329
  • [29] LC-MS/MS method for simultaneous quantification of ten antibiotics in human plasma for routine therapeutic drug monitoring
    Radovanovic, Mirjana
    Day, Richard O.
    Jones, Graham D. R.
    Galettis, Peter
    Norris, Ross L. G.
    JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB, 2022, 26 : 48 - 59
  • [30] Development and clinical validation of an LC-MS/MS method for the quantification of pazopanib in DBS
    Verheijen, Remy B.
    Bins, Sander
    Thijssen, Bas
    Rosing, Hilde
    Nan, Lianda
    Schellens, Jan H. M.
    Mathijssen, Ron H. J.
    Lolkema, Martijn P.
    Beijnen, Jos H.
    Steeghs, Neeltje
    Huitema, Alwin D. R.
    BIOANALYSIS, 2016, 8 (02) : 123 - 134