Simultaneous charging and discharging of metal foam composite phase change material in triplex-tube latent heat storage system under various configurations

被引:2
|
作者
Alam, Md Tabrez [1 ]
Gupta, Anoop K. [1 ]
机构
[1] Indian Inst Technol Patna, Dept Chem & Biochem Engn, Energy & Thermofluids Lab, Patna 801106, India
来源
CHEMICAL PRODUCT AND PROCESS MODELING | 2023年 / 18卷 / 05期
关键词
metal foam; phase change material; simultaneous charging and discharging; triplex-tube; ENERGY-STORAGE; MELTING PERFORMANCE; HORIZONTAL CYLINDER; PCM; ENHANCEMENT; EXCHANGER; OPTIMIZATION; FINS;
D O I
10.1515/cppm-2023-0003
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Phase change material (PCM) has high latent heat on one hand albeit low thermal conductivity on the other hand which restricts its utilization in thermal energy storage applications. Therefore, to improve thermal performance of PCM, various techniques have been employed. This numerical work intends to estimate the effect of copper metal foam (MF) in the seven various configurations (M1-M7) of triple-tube heat exchanger (TTHX) under simultaneous charging and discharging (SCD) conditions using heat transfer fluids (HTF) both the sides. Five distinct configurations with equal volumes of PCM and composite PCM (CPCM) have been considered for optimization standpoint. RT55 (melting temperature = 327 K) is taken as PCM. Based on thermo-physical properties of PCM and thermal boundary conditions on the heated tube, the dimensionless controlling parameters such as the Rayleigh number (Ra), Prandtl number (Pr), and Stefan number (Ste) were taken as 1.79 x 10(5), 30, and 0.21, respectively. Typical results on melt fraction, latent heat storage, temperature contours, and steady-state melt fraction and corresponding melting time have been reported. Performance yielded by all the configurations was compared for a fixed duration of 2 h. The positioning of MF largely affects the heat transfer mechanism in the latent heat storage unit. Results show that the bottom-side positioning of MF can boost the heat storage due to enhanced buoyancy-induced convection. Among all the models, M3 predicts the highest steady-state melt fraction (lambda(ss) approximate to 0.62) in the shortest steady-state melting time (t (ss) approximate to 66 min), followed by model M6 (lambda(ss) approximate to 0.58, t (ss) approximate to 65 min). The optimized design (model M3) shows similar to 75 % latent heat storage enhancement than pure PCM (M1) case. Interestingly, one may also achieve similar to 17.2 % higher enhancement using model M3 than M2 but with only half of the mass of MF than that used in full porous configuration (M2).
引用
下载
收藏
页码:823 / 837
页数:15
相关论文
共 50 条
  • [31] Solidification expedition of Phase Change Material in a triplex-tube storage unit via novel fins and SWCNT nanoparticles
    Alizadeh, M.
    Pahlavanian, M. H.
    Tohidi, M.
    Ganji, D. D.
    JOURNAL OF ENERGY STORAGE, 2020, 28 (28)
  • [32] Phase change material thermal response under simultaneous charging and discharging process in an annular finned storage system with orientations: An experimental study
    Khobragade S.
    Devanuri J.K.
    International Journal of Thermofluids, 2023, 17
  • [33] Partial charging/discharging of bio-based latent heat energy storage enhanced with metal foam sheets
    Zadeh, Seyed Mohsen Hashem
    Ghodrat, Maryam
    Ayoubloo, Kasra Ayoubi
    Sedaghatizadeh, Nima
    Taylor, Robert A.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 130
  • [34] Heat transfer enhancement of phase change materials by fins under simultaneous charging and discharging
    Joybari, Mahmood Mastani
    Haghighat, Fariborz
    Seddegh, Saeid
    Al-Abidi, Abduljalil A.
    ENERGY CONVERSION AND MANAGEMENT, 2017, 152 : 136 - 156
  • [35] COMPOSITE PHASE CHANGE MATERIAL WITH METAL FOAM IN SHELL AND CONVERGENT TUBE THERMAL ENERGY STORAGE SYSTEMS
    Buonomo, Bernardo
    Golia, Maria Rita
    Manca, Oronzio
    Nardini, Sergio
    Plomitallo, Renato Elpidio
    PROCEEDINGS OF ASME 2023 HEAT TRANSFER SUMMER CONFERENCE, HT2023, 2023,
  • [36] Experimental and numerical study of solidifying phase-change material in a triplex-tube heat exchanger with longitudinal/triangular fins
    Abdulateef, Ammar M.
    Abdulateef, Jasim
    Mat, Sohif
    Sopian, Kamaruzzaman
    Elhub, Bashir
    Mussa, Munther Abdullah
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2018, 90 : 73 - 84
  • [37] Heat Transfer Augmentation Using Duplex and Triplex Tube Phase Change Material (PCM) Heat Exchanger Configurations
    Zaib, Aurang
    Mazhar, Abdur Rehman
    Aziz, Shahid
    Talha, Tariq
    Jung, Dong-Won
    ENERGIES, 2023, 16 (10)
  • [38] Design of a latent heat thermal energy storage system under simultaneous charging and discharging for solar domestic hot water applications
    Yang, Moucun
    Moghimi, M. A.
    Loillier, R.
    Markides, C. N.
    Kadivar, M.
    APPLIED ENERGY, 2023, 336
  • [39] Numerical study of the heat charging and discharging characteristics of a shell-and-tube phase change heat storage unit
    Wang, Wei-Wei
    Zhang, Kun
    Wang, Liang-Bi
    He, Ya-Ling
    APPLIED THERMAL ENGINEERING, 2013, 58 (1-2) : 542 - 553
  • [40] Melting effect in triplex-tube thermal energy storage system using multiple PCMs-porous metal foam combination
    Abandani, Mohammadreza Hassani Soukht
    Ganji, Davoud Domiri
    JOURNAL OF ENERGY STORAGE, 2021, 43