Detection of Broken Bars in Induction Motors Using Histogram Analysis of Current Signals

被引:6
|
作者
Hernandez-Ramirez, Veronica [1 ,2 ]
Almanza-Ojeda, Dora-Luz [1 ]
Cardenas-Cornejo, Juan-Jose [1 ]
Contreras-Hernandez, Jose-Luis [1 ]
Ibarra-Manzano, Mario-Alberto [1 ]
机构
[1] Univ Guanajuato, Elect Engn Dept, Engn Div Irapuato Salamanca Campus, Carr Salamanca Valle Santiago KM 3 5 1 8 Km, Salamanca 36885, Mexico
[2] Univ Guanajuato, Multidisciplinary Studies Dept, Engn Div Irapuato Salamanca Campus, Av Univ, Yuriria 38944, Mexico
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 14期
关键词
broken rotor bars; SDH; current signals; induction motors; texture features; regression analysis;
D O I
10.3390/app13148344
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The lifetime of induction motors can be significantly extended by installing diagnostic systems for monitoring their operating conditions. In particular, detecting broken bar failures in motors is important for avoiding the risk of short circuits or other accidents with serious consequences. In the literature, many approaches have been proposed for motor fault detection; however, additional generalized methods based on local and statistical analysis could provide a low-complexity and feasible solution in this field of research. The proposed work presents a methodology for detecting one or two broken rotor bars using the sums and differences histograms (SDH) and machine learning classifiers in this context. From the SDH computed in one phase of the motor's current, nine texture features are calculated for different displacements. Then, all features are used to train two classifiers and to find the best displacements for faults and health identification in the induction motors. A final experimental evaluation considering the best displacements shows an accuracy of 98.16% for the homogeneity feature and a few signal samples used in a decision tree classifier. Additionally, a polynomial regression curve validates the use of 50 samples to obtain an accuracy of 88.15%, whereas the highest performance is achieved for 250 samples.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Diagnosis of simultaneous broken rotor bars and static eccentricity faults of induction motors by analyzing stator current and vibration signals
    Kabul, Ahmet
    Unsal, Abdurrahman
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2021, 36 (04): : 2011 - 2023
  • [32] Analysis of Magnetic Field Distribution in Induction Motors with Broken Rotor Bars
    Anca, Ciobanu
    Elena, Helerea
    2013 4TH INTERNATIONAL SYMPOSIUM ON ELECTRICAL AND ELECTRONICS ENGINEERING (ISEEE), 2013,
  • [33] Calculation and analysis of temperature field for induction motors with broken bars fault
    Harbin University of Science and Technology, Harbin 150040, China
    不详
    Diangong Jishu Xuebao, 2008, 10 (33-39+46):
  • [34] Analysis and Diagnosis of Broken Rotor Bars in Induction Motors Based on Maxwell
    Lv Yuegang
    Zhang Wenyuan
    Liu Juncheng
    2014 33RD CHINESE CONTROL CONFERENCE (CCC), 2014, : 3065 - 3069
  • [35] Detection of broken rotor bars in induction motor using starting-current analysis and effects of loading
    Supangat, R.
    Ertugrul, N.
    Soong, W. L.
    Gray, D. A.
    Hansen, C.
    Grieger, J.
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2006, 153 (06): : 848 - 855
  • [36] Early Detection of Broken Rotor Bars in Inverter-Fed Induction Motors Using Speed Analysis of Startup Transients
    Garcia-Calva, Tomas A.
    Morinigo-Sotelo, Daniel
    Fernandez-Cavero, Vanessa
    Garcia-Perez, Arturo
    Romero-Troncoso, Rene de J.
    ENERGIES, 2021, 14 (05)
  • [37] Faulty evolution of broken bars in induction motors and correlative factors analysis
    Xie, Ying
    Li, Weili
    Li, Shoufa
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2007, 22 (03): : 41 - 48
  • [38] Detection of Broken Rotor Bars Faults in Inverter-Fed Induction Motors
    Godoy, W. F.
    da Silva, I. N.
    Goedtel, A.
    Palacios, R. H. C.
    Scalassara, P.
    Morinigo-Sotelo, D.
    Duque-Perez, O.
    2018 XIII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2018, : 1803 - 1808
  • [39] Robust condition monitoring for early detection of broken rotor bars in induction motors
    Garcia-Escudero, Luis A.
    Duque-Perez, Oscar
    Morinigo-Sotelo, Daniel
    Perez-Alonso, Marcelo
    EXPERT SYSTEMS WITH APPLICATIONS, 2011, 38 (03) : 2653 - 2660
  • [40] DETERMINATION OF INTERBAR CURRENT EFFECTS IN THE DETECTION OF BROKEN ROTOR BARS IN SQUIRREL-CAGE INDUCTION-MOTORS
    WALLISER, RF
    LANDY, CF
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1994, 9 (01) : 152 - 158