Reduced Graphene Oxide-Polydopamine-Gold Nanoparticles: A Ternary Nanocomposite-Based Electrochemical Genosensor for Rapid and Early Mycobacterium tuberculosis Detection

被引:18
|
作者
Chaturvedi, Mansi [1 ,2 ]
Patel, Monika [1 ,3 ]
Bisht, Neha [1 ]
Mukherjee, Maumita Das [4 ]
Tiwari, Archana [2 ]
Mondal, D. P. [1 ,3 ]
Srivastava, Avanish Kumar [1 ,3 ]
Dwivedi, Neeraj [1 ,3 ]
Dhand, Chetna [1 ,3 ]
机构
[1] CSIR, Adv Mat & Proc Res Inst, Hoshangabad Rd, Bhopal 462026, India
[2] UTD RGPV, Sch Biomol Engn & Biotechnol, Bhopal 462033, India
[3] Acad Sci & Innovat Res AcSIR, Ghaziabad 201002, India
[4] Amity Univ Uttar Pradesh, Amity Inst Appl Sci, Delhi 201303, India
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 03期
关键词
electrochemical biosensor; Mycobacterium tuberculosis; polydopamine; reduced graphene oxide; gold nanoparticle; DNA BIOSENSOR; FILMS;
D O I
10.3390/bios13030342
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tuberculosis (TB) has been a devastating human illness for thousands of years. According to the WHO, around 10.4 million new cases of tuberculosis are identified every year, with 1.8 million deaths. To reduce these statistics and the mortality rate, an early and accurate TB diagnosis is essential. This study offers a highly sensitive and selective electrochemical biosensor for Mycobacterium tuberculosis (MTB) detection based on a ternary nanocomposite of reduced graphene oxide, polydopamine, and gold nanoparticles (rGO-PDA-AuNP). Avidin-biotin coupling was used to bind the MTB probe DNA onto the rGO-PDA-AuNP modified glassy carbon electrode (ssDNA/avidin/rGO-PDA-AuNP). UV-Visible, Raman, XRD, and TEM were used to evaluate the structural and morphological characteristics of rGO-PDA-AuNP. Furthermore, DNA immobilization is validated using FESEM and FT-IR techniques. The modified electrodes were electrochemically analyzed using cyclic voltammetry (CV) and linear sweep voltammetry (LSV), and the results indicate that the produced electrode can detect target DNA up to 0.1 x 10(-7) mM with 2.12 x 10(-3) mA mu M-1 sensitivity and a response time of 5 s. The constructed genosensor displayed high sensitivity and stability, and it also provides a unique strategy for diagnosing MTB at an early stage. Furthermore, our rGO-PDA-AuNP/GCE-based electrochemical platform has broad potential for creating biosensor systems for detecting various infectious pathogens and therapeutically significant biomarkers.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Electrochemical IFN-γ immunosensor based on a nanocomposite of gold nanorods and reduced graphene oxide
    Yerrapragada, Manjoosha R.
    Kunnambra, Beharuza Farha
    Pillai, Vijayamohanan K.
    Mampallil, Dileep
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2024, 54 (01) : 127 - 135
  • [32] Neodymium-polydopamine-reduced graphene oxide nanocomposite: A high-performance electrochemical sensor for paracetamol detection
    Mahalakshmi, B.
    Venkatesh, P.
    Sudhakar, K.
    Gayathri, G. S.
    INORGANIC CHEMISTRY COMMUNICATIONS, 2025, 173
  • [33] Yttrium Functionalized Reduced Graphene Oxide Nanocomposite-Based Aptasensor for Ultrasensitive Detection of a Breast Cancer Biomarker
    Parihar, Arpana
    Khan, Raju
    ACS APPLIED NANO MATERIALS, 2023, 7 (16) : 18207 - 18218
  • [34] Electrochemical Detection of Gentamicin Using a Reduced Graphene Oxide-Yttria Oxide (rGO@Y2O3) Nanocomposite-Based Biosensor
    Himanshu, Jayendra Kumar
    Verma, Damini
    Lakshmi, G. B. V. S.
    Singh, Akhilesh Kumar
    Solanki, Pratima R.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (12)
  • [35] Highly Sensitive Amperometric Sensor Based on Gold Nanoparticles Polyaniline Electrochemically Reduced Graphene Oxide Nanocomposite for Detection of Nitric Oxide
    Pashai, E.
    Najafpour, G. D.
    Jahanshahi, M.
    Rahimnejad, M.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2018, 31 (02): : 188 - 195
  • [36] 3D gold dendrite and reduced graphene oxide-chitosan nanocomposite-based immunosensor for carcinoembryonic antigen detection in clinical settings
    Purohit, Buddhadev
    Kumar, Ashutosh
    Kumari, Rohini
    Mahato, Kuldeep
    Roy, Sharmilli
    Srivastava, Ananya
    Chandra, Pranjal
    SURFACES AND INTERFACES, 2024, 47
  • [37] A reduced graphene oxide-titanium dioxide nanocomposite based electrochemical aptasensor for rapid and sensitive detection of Salmonella enterica
    Muniandy, Shalini
    Teh, Swe Jyan
    Appaturi, Jimmy Nelson
    Thong, Kwai Lin
    Lai, Chin Wei
    Ibrahim, Fatimah
    Leo, Bey Fen
    BIOELECTROCHEMISTRY, 2019, 127 : 136 - 144
  • [38] Rapid and sensitive electrochemical detection of myricetin based on polyoxometalates/SnO2/gold nanoparticles ternary nanocomposite film electrode
    Xing, Ruimin
    Tong, Liangyu
    Zhao, Xiaoyu
    Liu, Hongling
    Ma, Pengtao
    Zhao, Junwei
    Liu, Xiaoqiang
    Liu, Shanhu
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 283 : 35 - 41
  • [39] An Impedimetric Aptasensor Based on Reduced Graphene Oxide/Carbon Nanotube-Gold Nanoparticles Nanocomposite for the Detection of Pseudomonas aeruginosa
    Jia F.
    Yan W.
    Dai R.
    Liu Y.
    Li X.
    Shipin Kexue/Food Science, 2021, 42 (18): : 284 - 291
  • [40] ZnS and Reduced Graphene Oxide Nanocomposite-Based Non-Enzymatic Biosensor for the Photoelectrochemical Detection of Uric Acid
    Zhao, Yao
    Peng, Niancai
    Gao, Weizhuo
    Hu, Fei
    Zhang, Chuanyu
    Wei, Xueyong
    BIOSENSORS-BASEL, 2024, 14 (10):