The Accuracy of Post and Core Fabricated with Digital Technology

被引:13
|
作者
Piangsuk, Tarin [1 ]
Dawson, Deborah, V [2 ]
El-Kerdani, Tarek [1 ]
Lindquist, Terry J. [1 ]
机构
[1] Univ Iowa, Dept Prosthodont, Coll Dent, 801 Newton Rd, Iowa City, IA 52242 USA
[2] Univ Iowa, Iowa Inst Oral Hlth Res, Coll Dent & Dent Clin, Iowa City, IA 52242 USA
关键词
3D printing; 3D milling; accuracy of post and core; customized post and core; post and core; CAST POSTS; SHRINKAGE;
D O I
10.1111/jopr.13522
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To compare the accuracy of post and cores created with three different fabricating techniques: direct conventional, machine milling, and three-dimensional (3D) printing. Materials and methods Thirteen extracted single root central incisors were selected. Root canal treatment and tooth preparation for crown were performed on all teeth. Post space preparation of 11 mm was created using prefabricated fiber post drill to standardize post space width and length. Root canal impressions were performed on all teeth using polyvinyl siloxane impression material. Each impression was then three dimensionally scanned using an extraoral lab scanner. The scanned impressions were used to design digital files of post and cores with 3Shape CAD software. The digitally designed post and cores were used to fabricate 3D printed and milled post and core resin patterns. The same teeth were used to fabricate post and core with conventional technique (direct duplication of root canal with resin pattern). All posts were then scanned before being invested and then cast using base metal educational alloy. The metal post and cores were tried in with sample teeth and manually adjusted until found to be clinically acceptable. The post and cores were scanned in different stages to perform digital volume measurement using Geomagic Control software to determine accuracy. Pairwise comparisons were accomplished using exact version of the sign test (alpha = 0.05). Results These three techniques of post and core fabrication showed different results in the various stages of fabrication. The accuracy of 3D printed resin pattern (26.89 +/- 11.09 mm(3)) was found to be inferior compare to milled resin pattern (28.20 +/- 11.41 mm(3), p = 0.0002). However, dimensional stability of the 3D printed resin pattern before and after casting (0.56 +/- 0.95 mm(3)) was found to be superior to milled resin pattern (0.79 +/- 0.89 mm(3)) and direct resin pattern (2.51 +/- 1.38 mm(3), p = 0.00002). All three techniques showed significant volume reduction after adjustment (p = 0.0002). In the final stage, the adjusted metal post and core fabricated with three different techniques showed no statistical different in accuracy (p = 0.15). Conclusion Digitally fabricated post and cores have the same degree of accuracy as those fabricated using the gold standard direct conventional post and core technique.
引用
收藏
页码:221 / 226
页数:6
相关论文
共 50 条
  • [31] Estimation of potential accuracy of angular encoders using the scales fabricated by raster scanning technology
    Kiryanov, AV
    Proceedings of the Second IASTED International Multi-Conference on Automation, Control, and Information Technology - Automation, Control, and Applications, 2005, : 37 - 39
  • [32] Design and measurement of very high bitrate digital ICs fabricated in InPHBT technology
    Konczykowska, A
    Blayac, S
    Jorge, F
    Riet, M
    Puyal, V
    Godin, J
    2003 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 2003, : 1177 - 1180
  • [33] MULTIPURPOSE INTERFACE FOR SENSOR SYSTEMS FABRICATED BY CMOS TECHNOLOGY WITH POST-PROCESSING
    LEME, CA
    BALTES, H
    SENSORS AND ACTUATORS A-PHYSICAL, 1993, 37-8 : 77 - 81
  • [34] Acoustic MWD caliper improves accuracy with digital-signal technology
    Maranuk, CA
    OIL & GAS JOURNAL, 1998, 96 (09) : 80 - +
  • [35] Digital core based transmitted ultrasonic wave simulation and velocity accuracy analysis
    Zhu Wei
    Shan Rui
    APPLIED GEOPHYSICS, 2016, 13 (02) : 375 - 381
  • [36] Digital core based transmitted ultrasonic wave simulation and velocity accuracy analysis
    Wei Zhu
    Rui Shan
    Applied Geophysics, 2016, 13 : 375 - 381
  • [37] The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems
    Brawek, Petya K.
    Wolfart, Stefan
    Endres, Lutz
    Kirsten, Armin
    Reich, Sven
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (09) : 2119 - 2125
  • [38] Digital assessment of marginal accuracy in ceramic crowns fabricated with different marginal finish line configurations
    Faruqi, Saif
    Ganji, Kiran Kumar
    Bandela, Vinod
    Nagarajappa, Anil Kumar
    Mohamed, Roshan Noor
    Al Ahmed, Muhannad
    Farhan, Mohammed
    Alwakid, Waleed Naif
    Al-Hammad, Kholood A. S.
    Alam, Mohammad Khursheed
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (05) : 789 - 795
  • [39] Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study
    Lee, Beom-Il
    You, Seung-Gyu
    You, Seung-Min
    Kang, Seen-Young
    Kim, Ji-Hwan
    JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (01): : 24 - 35
  • [40] Effect of Printing Parameters on the Surface Roughness and Dimensional Accuracy of Digital Light Processing Fabricated Parts
    Kaushik, Ashish
    Garg, Ramesh Kumar
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2024, 33 (21) : 11863 - 11875