Validity and Reliability of Thoracic-Mounted Inertial Measurement Units to Derive Gait Characteristics During Running

被引:1
|
作者
Horsley, Benjamin J. [1 ,2 ]
Tofari, Paul J. [1 ,2 ]
Halson, Shona L. [1 ,2 ]
Kemp, Justin G. [2 ]
Chalkley, Daniel [2 ]
Cole, Michael H. [2 ]
Johnston, Rich D. [1 ,2 ,3 ]
Cormack, Stuart J. [1 ,2 ]
机构
[1] Australian Catholic Univ, Sports Performance Recovery Injury & New Technol S, Melbourne, Australia
[2] Australian Catholic Univ, Sch Behav & Hlth Sci, Melbourne, Australia
[3] Leeds Beckett Univ, Carnegie Appl Rugby Res CARR Ctr, Leeds, England
关键词
accelerometers; gait analysis; sprinting; stiffness; trunk; NEUROMUSCULAR FATIGUE; VERTICAL STIFFNESS; TIME; LOAD;
D O I
10.1519/JSC.0000000000004612
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Supplemental Digital Content is Available in the Text. Horsley, BJ, Tofari, PJ, Halson, SL, Kemp, JG, Chalkley, D, Cole, MH, Johnston, RD, and Cormack, SJ. Validity and reliability of thoracic-mounted inertial measurement units to derive gait characteristics during running. J Strength Cond Res 38(2): 274-282, 2024-Inertial measurement units (IMUs) attached to the tibia or lumbar spine can be used to analyze running gait but, with team-sports, are often contained in global navigation satellite system (GNSS) units worn on the thoracic spine. We assessed the validity and reliability of thoracic-mounted IMUs to derive gait characteristics, including peak vertical ground reaction force (vGRFpeak) and vertical stiffness (Kvert). Sixteen recreationally active subjects performed 40 m run throughs at 3-4, 5-6, and 7-8 m center dot s-1. Inertial measurement units were attached to the tibia, lumbar, and thoracic spine, whereas 2 GNSS units were also worn on the thoracic spine. Initial contact (IC) from a validated algorithm was evaluated with F1 score and agreement (mean difference +/- SD) of gait data with the tibia and lumbar spine using nonparametric limits of agreement (LoA). Test-retest error {coefficient of variation, CV (95% confidence interval [CI])} established reliability. Thoracic IMUs detected a nearly perfect proportion (F1 >= 0.95) of IC events compared with tibia and lumbar sites. Step length had the strongest agreement (0 +/- 0.04 m) at 3-4 m center dot s-1, whereas contact time improved from 3 to 4 (-0.028 +/- 0.018 second) to 7-8 m center dot s-1 (-0.004 +/- 0.013 second). All values for Kvert fell within the LoA at 7-8 m center dot s-1. Test-retest error was <= 12.8% for all gait characteristics obtained from GNSS units, where Kvert was most reliable at 3-4 m center dot s-1 (6.8% [5.2, 9.6]) and vGRFpeak at 7-8 m center dot s-1 (3.7% [2.5, 5.2]). The thoracic-spine site is suitable to derive gait characteristics, including Kvert, from IMUs within GNSS units, eliminating the need for additional sensors to analyze running gait.
引用
收藏
页码:274 / 282
页数:9
相关论文
共 50 条
  • [31] The Analytical Validity of Stride Detection and Gait Parameters Reconstruction Using the Ankle-Mounted Inertial Measurement Unit Syde®
    Michaud, Mona
    Guerin, Alexandre
    de la Batie, Marguerite Dejean
    Bancel, Leopold
    Oudre, Laurent
    Tricot, Alexis
    SENSORS, 2024, 24 (08)
  • [32] Estimation of temporal parameters during sprint running using a trunk-mounted inertial measurement unit
    Bergamini, Elena
    Picerno, Pietro
    Pillet, Helene
    Natta, Francoise
    Thoreux, Patricia
    Camomilla, Valentina
    JOURNAL OF BIOMECHANICS, 2012, 45 (06) : 1123 - 1126
  • [33] The development and concurrent validity of a real-time algorithm for temporal gait analysis using inertial measurement units
    Allseits, E.
    Lucarevic, J.
    Gailey, R.
    Agrawal, V.
    Gaunaurd, I.
    Bennett, C.
    JOURNAL OF BIOMECHANICS, 2017, 55 : 27 - 33
  • [34] Concurrent validity and between-unit reliability of a foot-mounted inertial measurement unit to measure velocity during team sport activity
    Myhill, Naomi
    Weaving, Dan
    Robinson, Mark
    Barrett, Steve
    Emmonds, Stacey
    SCIENCE AND MEDICINE IN FOOTBALL, 2024, 8 (04) : 308 - 316
  • [35] Using inertial measurement units to estimate spine joint kinematics and kinetics during walking and running
    Sibson, Benjamin E.
    Banks, Jacob J.
    Yawar, Ali
    Yegian, Andrew K.
    Anderson, Dennis E.
    Lieberman, Daniel E.
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [36] Using inertial measurement units to estimate spine joint kinematics and kinetics during walking and running
    Benjamin E. Sibson
    Jacob J. Banks
    Ali Yawar
    Andrew K. Yegian
    Dennis E. Anderson
    Daniel E. Lieberman
    Scientific Reports, 14
  • [37] Concurrent validation of magnetic and inertial measurement units in estimating upper body posture during gait
    Kang, Gu Eon
    Gross, M. Melissa
    MEASUREMENT, 2016, 82 : 240 - 245
  • [38] Validity of Measurement for Trailing Limb Angle and Propulsion Force during Gait Using a Magnetic Inertial Measurement Unit
    Miyazaki, Takasuke
    Kawada, Masayuki
    Nakai, Yuki
    Kiyama, Ryoji
    Yone, Kazunori
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [39] Assessing the Reliability and Validity of Inertial Measurement Units to Measure Three-Dimensional Spine and Hip Kinematics During Clinical Movement Tasks
    Bailes, Anna H.
    Johnson, Marit
    Roos, Rachel
    Clark, William
    Cook, Harold
    McKernan, Gina
    Sowa, Gwendolyn A.
    Cham, Rakie
    Bell, Kevin M.
    SENSORS, 2024, 24 (20)
  • [40] Inertial Measurement Units' Reliability for Measuring Knee Joint Angle during Road Cycling
    Obradovic, Sasa
    Stancin, Sara
    ELECTRONICS, 2023, 12 (03)