A Simple Flow Injection System for Amperometric Detection of Ascorbic Acid Using Carbon Paste/Copper Schiff Base Composite Electrode

被引:0
|
作者
Kulizic, Mihajlo [2 ]
Stankovic, Milan [3 ]
Rasic, Marija [4 ]
Mijatovic, Aleksandar [5 ]
Baosic, Rada [1 ]
Lolic, Aleksandar [1 ]
机构
[1] Univ Belgrade, Fac Chem, Dept Analyt Chem, Studentski Trg 12, Belgrade 11000, Serbia
[2] Innovat Ctr Fac Chem Ltd, Studentski Trg 12, Belgrade 11000, Serbia
[3] Univ Belgrade, Fac Pharm, Dept Analyt Chem, Vojvode Stepe 450, Belgrade 11000, Serbia
[4] Miphem Lab, Matice Srpske 57e, Belgrade 11000, Serbia
[5] Univ Belgrade, Fac Min & Geol, Dusina 7, Belgrade 11000, Serbia
来源
CHEMISTRYSELECT | 2023年 / 8卷 / 48期
关键词
ascorbic acid; modified carbon paste electrode; flow injection analysis; dietary supplements; amperometry; SIMULTANEOUS VOLTAMMETRIC DETERMINATION; GRAPHENE OXIDE;
D O I
10.1002/slct.202304631
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this paper, a simple, sensitive, and precise flow injection system was optimized and applied to ascorbic acid determination with a carbon paste electrode modified with the Schiff base copper complex. The modified sensor showed increased sensitivity toward ascorbic acid oxidation with a decrease of oxidation potential by 200 mV. Under optimized flow parameters, working potential, gasket thickness, sample and reaction coil volumes, and flow rate, the developed flow system gave a linear response from 5 to 75 mu mol/L of ascorbic acid. The calculated limit of detection was 4.5 mu mol/L, calculated as 3 sigma/s which corresponds to the absolute value of 40 ng for the 50 mu L sample coil. The precision for six consecutive injections of 5 and 75 mu mol/L ascorbic acid solutions was determined as a relative standard deviation of 5.8 % and 1.5 %, respectively. The flow injection system enabled up to 120 analyses per hour. An optimized flow system was applied to the determination of ascorbic acid in dietary supplements, after simple preparation. The carbon paste electrode, modified by Copper Schiff base complex, was used for electrooxidation of ascorbic acid in a flow injection amperometric system. Physical and chemical parameters of the flow system were optimized. Under optimal conditions the system was successfully applied on ascorbic acid determination in dietary supplements.image
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Voltammetric determination of copper in water samples using a Schiff base/carbon nanotube-modified carbon paste electrode
    Izadkhah, V.
    Farmany, A.
    Mortazavi, S. S.
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2015, 21 : 994 - 996
  • [22] Electrochemical Sensing of Folic Acid in Presence of Ascorbic acid Using Carbon Paste Nano Composite Modified Electrode
    Vafaee-Shahi, Shohre
    Shishehbore, M. Reza
    Sheibani, Ali
    Tabatabaee, Masoumeh
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2021, 8 (03): : 261 - 274
  • [23] SIMULTANEOUS DETERMINATION OF ASCORBIC ACID AND ACETYLSALICYLIC ACID USING FLOW INJECTION ANALYSIS WITH MULTIPLE PULSE AMPEROMETRIC DETECTION
    de Miranda, Joyce A. T.
    Cunha, Rafael R.
    Gimenes, Denise T.
    Munoz, Rodrigo A. A.
    Richter, Eduardo M.
    QUIMICA NOVA, 2012, 35 (07): : 1459 - 1463
  • [24] Amperometric flow injection analysis of glucose using immobilized glucose oxidase on nano-composite carbon nanotubes-platinum nanoparticles carbon paste electrode
    Amatatongchai, Maliwan
    Sroysee, Wongduan
    Chairam, Sanoe
    Nacapricha, Duangjai
    TALANTA, 2017, 166 : 420 - 427
  • [25] Amperometric ascorbic acid sensor based on doped ferrites nanoparticles modified glassy carbon paste electrode
    Dimitrijevic, Teodora
    Vulic, Predrag
    Manojlovic, Dragan
    Nikolic, Aleksandar S.
    Stankovic, Dalibor M.
    ANALYTICAL BIOCHEMISTRY, 2016, 504 : 20 - 26
  • [26] β-Cyclodextrin-ferrocene inclusion complex modified carbon paste electrode for amperometric determination of ascorbic acid
    Zhang, GR
    Wang, XL
    Shi, XW
    Sun, TL
    TALANTA, 2000, 51 (05) : 1019 - 1025
  • [27] FLOW-INJECTION DETERMINATION OF NOVALGIN USING AMPEROMETRIC DETECTION AT A GLASSY-CARBON ELECTRODE
    PEREZRUIZ, T
    LOZANO, CM
    TOMAS, V
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (09) : 1109 - 1113
  • [28] Flow Injection Amperometric Detection of Sulfide Using a Prussian Blue Modified Glassy Carbon Electrode
    Bensu Ertek
    Dai Long Vu
    Libor Červenka
    Yusuf Dilgin
    Analytical Sciences, 2012, 28 : 1075 - 1080
  • [29] Flow Injection Amperometric Detection of Sulfide Using a Prussian Blue Modified Glassy Carbon Electrode
    Ertek, Bensu
    Vu, Dai Long
    Cervenka, Libor
    Dilgin, Yusuf
    ANALYTICAL SCIENCES, 2012, 28 (11) : 1075 - 1080
  • [30] Determination of Benzocaine Using HPLC and FIA with Amperometric Detection on a Carbon Paste Electrode
    Dejmkova, Hana
    Vokalova, Veronika
    Zima, Jiri
    Barek, Jiri
    ELECTROANALYSIS, 2011, 23 (03) : 662 - 666