Comparison of AO, Schatzker, and three-column classification systems in tibial plateau fractures: Impact on functional outcomes

被引:3
|
作者
Selcuk, Esref [1 ]
Erem, Murat [1 ]
Copuroglu, Cem [1 ]
Ozcan, Mert [1 ]
Ciftdemir, Mert [1 ]
机构
[1] Trakya Univ, Fac Med, Dept Orthoped & Traumatol, TR-22030 Edirne, Turkiye
来源
JOINT DISEASES AND RELATED SURGERY | 2024年 / 35卷 / 01期
关键词
Classification; health care; outcome assessment; tibial plateau fractures; OSTEOARTHRITIS; RELIABILITY;
D O I
10.52312/jdrs.2023.1256
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: This study aimed to compare the AO, Schatzker, and Three-Column classification systems for tibial plateau fractures, focusing on their prognostic and functional outcome prediction and influence on clinical decisions across different trauma types. Patients and methods: In this retrospective study, we examined 49 patients (36 males, 11 females; mean age: 40.6 +/- 11.8 years; range, 19 to 67 years) with tibial plateau fractures between January 2011 and January 2017. The fractures were classified using the AO, Schatzker, and three-column systems. The main outcome measurements included functional scores (Knee Injury and Osteoarthritis Outcome Score [KOOS], Hospital for Special Surgery [HSS]), range of motion (ROM), duration of hospitalization, thigh atrophy, operation time, and the development of osteoarthritis. The impact of smoking was also assessed. Results: According to the AO classification, type B fractures obtained higher KOOS and HSS scores compared to type C fractures (p=0.013 and p=0.007, respectively). According to the Schatzker classification low-energy fractures achieved higher KOOS and HSS scores than high-energy fractures (p=0.013 and p=0.026, respectively). One-column fractures had higher KOOS and HSS scores compared to two-column and three-column fractures (p=0.007 and p=0.001, respectively). Two-column fractures had a lower ROM compared to other column fractures (p=0.022). Shorter hospital stays were recorded for Schatzker low-energy fractures (p=0.016), whereas higher thigh atrophy was found in Schatzker high-energy fractures (p=0.022) and AO type C fractures (p=0.018). Longer operation times were observed in AO type C fractures (p=0.037) and Schatzker high-energy fractures (p=0.017). According to the Kellgren-Lawrence classification, AO type C fractures and three-column fractures yielded worse outcomes (p=0.039 and p=0.001, respectively). Smoking had a negative impact on functional KOOS and HSS scores across all groups (p=0.022 and p=0.001, respectively). Conclusion: This study highlights the predictive value of the AO, Schatzker, and Three-Column classification systems in determining functional outcomes and clinical data in tibial plateau fractures. Each system provides unique insights into different outcomes, suggesting their concurrent application may yield a more comprehensive prognosis.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 50 条
  • [21] Three-Column Classification for Acetabular Fractures Introduction and Reproducibility Assessment
    Zhang, Ruipeng
    Yin, Yingchao
    Li, Ao
    Wang, Zhongzheng
    Hou, Zhiyong
    Zhuang, Yan
    Fan, Shicai
    Wu, Zhanyong
    Yi, Chengla
    Lyu, Gang
    Ma, Xianzhong
    Zhang, Yingze
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (22): : 2015 - 2025
  • [22] Functional outcome of intra-articular tibial plateau fractures: the impact of posterior column fractures
    Juriaan van den Berg
    Maike Reul
    Menno Nunes Cardozo
    Anastasiya Starovoyt
    Eric Geusens
    Stefaan Nijs
    Harm Hoekstra
    International Orthopaedics, 2017, 41 : 1865 - 1873
  • [23] Functional outcome of intra-articular tibial plateau fractures: the impact of posterior column fractures
    van den Berg, Juriaan
    Reul, Maike
    Cardozo, Menno Nunes
    Starovoyt, Anastasiya
    Geusens, Eric
    Nijs, Stefaan
    Hoekstra, Harm
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (09) : 1865 - 1873
  • [24] INTER- AND INTRA-OBSERVER RELIABILITY OF SCHATZKER, AO, AND LUO CLASSIFICATIONS FOR TIBIAL PLATEAU FRACTURES
    de Alencar Neto, Jonatas Brito
    Duarte de Souza, Clodoaldo Jose
    Reis Coelho, Pedro Rafael
    de Freitas Junior, Pedro Gomes
    Gadelha Lopes, Marcio Bezerra
    Maia Pinto, Francisco Jose
    ACTA ORTOPEDICA BRASILEIRA, 2020, 28 (05): : 216 - 220
  • [25] Circular frame fixation of complex tibial plateau fractures in the elderly: Functional and radiological outcomes for Schatzker V and VI type fractures
    Robinson, R. M.
    Mackey, R.
    Ogonda, L.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (12):
  • [26] Reliability of a four-column classification for tibial plateau fractures
    Alfredo Martínez-Rondanelli
    Sara Sofía Escobar-González
    Alejandro Henao-Alzate
    Juan Pablo Martínez-Cano
    International Orthopaedics, 2017, 41 : 1881 - 1886
  • [27] Four-quadrant/column classification of tibial plateau fractures
    Chang, Shi-Min
    Hu, Sun-Jun
    Du, Shou-Chao
    Ma, Zhuo
    Xiong, Wen-Feng
    Yao, Xi-Zhou
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (03) : 725 - 727
  • [28] Reliability of a four-column classification for tibial plateau fractures
    Martinez-Rondanelli, Alfredo
    Sofia Escobar-Gonzalez, Sara
    Henao-Alzate, Alejandro
    Pablo Martinez-Cano, Juan
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (09) : 1881 - 1886
  • [29] Inter- and intra-observer variation of the Schatzker and AO/OTA classifications of tibial plateau fractures and a proposal of a new classification system
    Charalambous, C. P.
    Tryfonidis, M.
    Alvi, F.
    Moran, M.
    Fang, C.
    Samaraji, R.
    Hirst, P.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2007, 89 (04) : 400 - 404
  • [30] Four-quadrant/column classification of tibial plateau fractures
    Shi-Min Chang
    Sun-Jun Hu
    Shou-Chao Du
    Zhuo Ma
    Wen-Feng Xiong
    Xi-Zhou Yao
    International Orthopaedics, 2018, 42 : 725 - 727