Experimental investigation of the performance of an air type photovoltaic thermal collector system with fixed cooling fins

被引:5
|
作者
Zhao, Zhonghua [1 ,4 ]
Zhu, Li [1 ,2 ]
Wang, Yiping [1 ,3 ]
Huang, Qunwu [3 ]
Sun, Yong [1 ,2 ]
机构
[1] Tianjin Univ, Sch Architecture, Tianjin 300072, Peoples R China
[2] Tianjin Univ, APEC Sustainable Energy Ctr, Tianjin 300072, Peoples R China
[3] Tianjin Univ, Sch Chem Engn & Technol, Tianjin 300072, Peoples R China
[4] Tianjin Renai Coll, Tianjin 301636, Peoples R China
关键词
Photovoltaic thermal (PV/T); Solar air collector; Thermal efficiency; Cooling fin; PV/T COLLECTOR; DESIGN;
D O I
10.1016/j.egyr.2023.02.059
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Solar energy may now be captured in two ways: heat extraction in solar collectors and electricity generation in photovoltaic panels. It may effectively reduce the degradation of PV cell efficiency caused by overheating of the battery by collecting the heat from the PV/T system. The heat dissipation cooling fin is directly mounted to the rear of the solar panel in this study and coated with an insulating layer to create an air-cooling channel. The heat dissipation fin transfers heat from the back of the photovoltaic panel to a certain mass flow of air in the flow channel, resulting in combined heat and power. The electrical and thermal capabilities of three distinct fin numbers were studied by monitoring electrical power and temperature data. A fixed mass flow rate (0.011 kg/s) for air, three different numbers of fins (0-5-10) and solar irradiance (200 W/m(2)-600 W/m(2)) are the experimental conditions. After the system was run stably for 10 min, the average temperature of the back of the PV panel, the device's inlet and outlet temperatures, and the PV panel's electric power were recorded. These figures are used to calculate the PV/T system's electrical and thermal efficiency. When the median electrical efficiency of the three types of fins is compared with varying solar irradiation, it is discovered that the electric efficiency value of the three types of fins is approximately 16%, with a difference of less than 0.6%. The comprehensive efficiency of five groups of fins and ten groups of fins was 61.08% and 69.85%, respectively, based on the median comparison of photoelectric photothermal comprehensive efficiency. The overall efficiency of the zero groups of fins was 26.27%, which was only 14.59% greater than the control plate, and there was a considerable difference between the five and ten groups of fins. This suggests that selecting the right number of fins has a substantial impact on improving PV/T thermal performance. This research will assist in further optimizing the design of PV/T systems for heat collection and will provide valuable information for PV/T system application in building integration. (c) 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under theCCBYlicense (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:93 / 100
页数:8
相关论文
共 50 条
  • [21] Experimental study of solar photovoltaic/thermal (PV/T) air collector drying performance
    Kong, Decheng
    Wang, Yunfeng
    Li, Ming
    Keovisar, Vanhkeo
    Huang, Mengxiao
    Yu, Qiongfen
    SOLAR ENERGY, 2020, 208 (208) : 978 - 989
  • [22] Experimental Investigation on Thermal Performance of a PV/T-PCM (Photovoltaic/Thermal) System Cooling with a PCM and Nanofluid
    Sarafraz, M. M.
    Safaei, Mohammad Reza
    Leon, Arturo S.
    Tlili, Iskander
    Alkanhal, Tawfeeq Abdullah
    Tian, Zhe
    Goodarzi, Marjan
    Arjomandi, M.
    ENERGIES, 2019, 12 (13)
  • [23] Experimental Performance Evaluation of a Photovoltaic Thermal (PV/T) Air Collector and Its Optimization
    Adeli, Mohsen Mandavi
    Sobhnamayan, Fatemeh
    Farahat, Said
    Alavi, Mahmood Abolhasan
    Sarhaddi, Faramarz
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2012, 58 (05): : 309 - 318
  • [24] Development of a dynamic model for a hybrid photovoltaic thermal collector - Solar air heater with fins
    Fan, Wenke
    Kokogiannakis, Georgios
    Ma, Zhenjun
    Cooper, Paul
    RENEWABLE ENERGY, 2017, 101 : 816 - 834
  • [25] Experimental and CFD investigation on temperature distribution of a serpentine tube type photovoltaic/thermal collector
    Zhou, Jicheng
    Ke, Haoyun
    Deng, Xiaoqing
    SOLAR ENERGY, 2018, 174 : 735 - 742
  • [26] Experimental investigation of thermal performance of a new solar air collector with porous surface
    Devecioglu, Atilla G.
    Oruc, Vedat
    INTERNATIONAL SCIENTIFIC CONFERENCE - ENVIRONMENTAL AND CLIMATE TECHNOLOGIES, CONECT 2016, 2017, 113 : 251 - 258
  • [27] Investigation of a Concentrating Photovoltaic Thermal Collector (CPVT) System
    Haddad, Salim
    Touafek, Khaled
    Tabet, Ismail
    Amirat, Yassine
    2016 ELEVENTH INTERNATIONAL CONFERENCE ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2016,
  • [28] Experimental investigation of a building integrated photovoltaic/thermal roof collector combined with a liquid desiccant enhanced indirect evaporative cooling system
    Buker, Mahmut Sami
    Mempouo, Blaise
    Riffat, Saffa B.
    ENERGY CONVERSION AND MANAGEMENT, 2015, 101 : 239 - 254
  • [29] Performance evaluation of a solar photovoltaic-thermal (PV/T) air collector system
    Dunne, Natalie Amber
    Liu, Pengfei
    Elbarghthi, Anas F. A.
    Yang, Yan
    Dvorak, Vaclav
    Wen, Chuang
    ENERGY CONVERSION AND MANAGEMENT-X, 2023, 20
  • [30] Experimental investigation on a novel solar photovoltaic/thermal system with flat aluminous box as collector
    Dept. of Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei 230026, China
    不详
    Taiyangneng Xuebao, 2006, 8 (765-773):