Hemodynamic study of blood flow in the aorta during the interventional robot treatment using fluid-structure interaction

被引:1
|
作者
Zhu, Zongming [1 ]
Ji, Suqiang [2 ]
Liang, Liang [1 ]
Wang, Hao [3 ]
Xia, Haoyu [4 ]
Tang, Puhua [1 ]
机构
[1] Changsha Univ, Coll Electromech Engn, Changsha 410022, Peoples R China
[2] Xiangtan Univ, Sch Mech Engn & Mech, Xiangtan 411105, Peoples R China
[3] Hunan Normal Univ, Coll Engn & Design, Changsha 410081, Peoples R China
[4] Changsha Inst Min Res Co LTD, Changsha 410012, Peoples R China
基金
中国国家自然科学基金;
关键词
Vascular interventional robot; Fluid-structure interaction (FSI); Hemodynamics; Computational fluid dynamics (CFD); Particle image velocimetry (PIV); DISSECTION; STENTS;
D O I
10.1007/s10237-023-01737-y
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An interventional robot is a means for vascular diagnosis and treatment, and it can perform dredging, releasing drug and operating. Normal hemodynamic indicators are a prerequisite for the application of interventional robots. The current hemodynamic research is limited to the absence of interventional devices or interventional devices in fixed positions. Considering the coupling effect of blood, vessels and robots, based on the bi-directional fluid-structure interaction, using the computational fluid dynamics and particle image velocimetry methods, combined with the sliding and moving mesh technologies, we theoretically and experimentally study the hemodynamic indicators such as blood flow lines, blood pressure, equivalent stress, deformation and wall shear stress of blood vessels when the robot precesses, rotates or does not intervene in the pulsating blood flow. The results show that the intervention of the robot increase the blood flow rate, blood pressure, equivalent stress and deformation of the vessels by 76.4%, 55.4%, 76.5%, and 346%, respectively. The operating mode of the robot during low-speed operation has little impact on the hemodynamic indicators. Using the methyl silicone oil as the experimental fluid, the elastic silicone pipe as the experimental pipe, and the intervention robot having a bioplastic outer shell, the velocity of the fluid around the robot is measured on the developed experimental device for fluid flow field in a pulsating flow when the robot runs. The experimental results are similar to the numerical results. Our work provides an important reference for the hemodynamic study and optimization of the mobile interventional devices.
引用
下载
收藏
页码:1857 / 1872
页数:16
相关论文
共 50 条
  • [1] Hemodynamic study of blood flow in the aorta during the interventional robot treatment using fluid–structure interaction
    Zongming Zhu
    Suqiang Ji
    Liang Liang
    Hao Wang
    Haoyu Xia
    Puhua Tang
    Biomechanics and Modeling in Mechanobiology, 2023, 22 : 1857 - 1872
  • [2] The fluid-structure interaction during blood flow in a flexible stenotic thoracic aorta: Numerical study
    Issakhov, Alibek
    Sabyrkulova, Aidana
    Abylkassymova, Aizhan
    COMPUTERS & MATHEMATICS WITH APPLICATIONS, 2024, 165 : 39 - 51
  • [3] Numerical modeling of the fluid-structure interaction during blood flow in a flexible stenotic aorta
    Issakhov, Alibek
    Sabyrkulova, Aidana
    Abylkassymova, Aizhan
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 158
  • [4] Hemodynamic Study of Blood Flow in the Carotid Artery With a Focus on Carotid Sinus Using Fluid-Structure Interaction
    Bantwal, Aditya
    Singh, Aditya
    Menon, Abhay Ramachandran
    Kumar, Nitesh
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (02):
  • [5] Mechanism of blood flow energy loss in real healthy aorta using computational fluid-structure interaction framework
    Qiao, Yonghui
    Fan, Jianren
    Luo, Kun
    INTERNATIONAL JOURNAL OF ENGINEERING SCIENCE, 2023, 192
  • [6] Blood Flow and Fluid-Structure Interactions in the Human Aorta during Traumatic Rupture Conditions
    Lee, Sang-Hyun
    Kent, Richard
    STAPP CAR CRASH JOURNAL, VOL 51, 2007, 51 : 211 - 233
  • [7] Fluid-structure interaction simulation of aortic blood flow
    Crosetto, Paolo
    Reymond, Philippe
    Deparis, Simone
    Kontaxakis, Dimitrios
    Stergiopulos, Nikolaos
    Quarteroni, Alfio
    COMPUTERS & FLUIDS, 2011, 43 (01) : 46 - 57
  • [8] Fluid-Structure Interaction Applied to Blood Flow Simulations
    Soudah, Eduardo
    Onate, Eugenio
    Garcia, Jose
    Perez, Jorge S.
    Mena, Andres
    Heindenreich, Elvio
    Felix Rodriguez, Jose
    Angel Martinez, Miguel
    Doblare, Manuel
    ADVANCES IN COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING: METHODS AND APPLICATIONS, 2009, 13 : 253 - +
  • [9] Fluid-Structure interaction applied to blood flow simulations
    Perez, J. S.
    Soudah, E.
    Garcia, J.
    Escolano, E.
    Onate, E.
    Mena, A.
    Heidenreich, E.
    Rodriguez, J. F.
    Doblare, M.
    COMPUTATIONAL VISION AND MEDICAL IMAGING PROCESSING, 2008, : 183 - 189
  • [10] Fluid-structure interaction of blood flow around a vein valve
    Hajati, Zahra
    Moghanlou, Farhad Sadegh
    Vajdi, Mohammad
    Razavi, Seyed Esmail
    Matin, Somaieh
    BIOIMPACTS, 2020, 10 (03) : 169 - 175