The Novel Hooked Kirschner Wire Technique for Ulna Coronoid Process Fractures

被引:3
|
作者
Jo, Seong-Woo [1 ]
Shin, Dong-Ju [1 ,2 ]
机构
[1] Daegu Fatima Hosp, Dept Orthoped Surg, Daegu, South Korea
[2] Daegu Fatima Hosp, Dept Orthoped Surg, 99 Ayang Ro, Daegu 41199, South Korea
关键词
Elbow joint; Ulnar coronoid process; Kirschner wires; ELBOW; FIXATION; DISLOCATIONS; ANATOMY;
D O I
10.4055/cios22148
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The aim of this study was to introduce a novel technique to improve the ease of fixing of even small fragments of the coronoid process and report the clinical outcomes of this method.Methods: Forty-nine patients with ulnar coronoid process fractures fixed using the hooked Kirschner wire (K-wire) technique at our hospital from 2007 to 2019 were reviewed. Radiological features and fracture union were assessed using simple radiographs. Functional outcomes of the treated elbows were evaluated at the final follow-up visit using the Mayo Elbow Performance ScoreResults: All patients were examined at a mean follow-up of 17.7 months (range, 6-62 months). We observed bony union in patients at a mean of 10.9 weeks (range, 6-22 weeks). The mean flexion and extension ranges of the elbow were 132.0 degrees (range, 106 degrees -151 degrees) and 4.5 degrees (range, -20 degrees to 30 degrees), respectively. The mean pronation and supination ranges of the forearm were 81.1 degrees (range, 60 degrees-90 degrees) and 88.3 degrees (range, 60 degrees-120 degrees), respectively. The mean arc of the elbow was 127.4 degrees (range, 78 degrees-160 degrees). All patients were evaluated using the MEPS at the final follow-up visit, with a mean score of 96.9 points (range, 80-100 points). One case of coronoid nonunion was observed and re-fixation was performed. One case of infection was observed and also treated with additional surgery. Three patients complained of ulnar nerve symptoms and 1 patient underwent surgical release for tardy ulnar nerve palsy.Conclusions: Despite its limitations, the hooked K-wire technique was a useful method for even smaller coronoid process fractures. K-wires were also a useful temporary intraoperative fixation method and could provide permanent fixation.
引用
收藏
页码:127 / 134
页数:8
相关论文
共 50 条
  • [21] Fractures of the coronoid process
    Cohen, MS
    HAND CLINICS, 2004, 20 (04) : 443 - +
  • [22] Fractures of the coronoid process of the ulna: Which ones to fix and which ones to leave alone: A review
    Samii, Amir
    Zellweger, Rene
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2008, 34 (02) : 113 - 119
  • [23] KIRSCHNER WIRE FIXATION IN FRACTURES OF THE CLAVICLE
    RIPSTEIN, CB
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1948, 59 (03) : 255 - 257
  • [24] Fractures of the Coronoid Process of the Ulna: Which Ones to Fix and Which Ones to Leave Alone: A Review
    Amir Samii
    René Zellweger
    European Journal of Trauma and Emergency Surgery, 2008, 34 : 113 - 119
  • [25] Novel method of Kirschner wire bending for treatment of displaced patella fractures
    Ju, Weina
    Sun, Di
    Qi, Baochang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (03): : 1955 - 1958
  • [26] Kirschner Wire Transfixation of Unstable Ankle Fractures: Indication, Surgical Technique and Outcomes
    Marvan, J.
    Dzupa, V.
    Bartoska, R.
    Kachlik, D.
    Krbec, M.
    Baca, V.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2015, 82 (03) : 216 - 221
  • [27] Percutaneous Reduction Technique Using a Kirschner Wire for Displaced Posterior Malleolar Fractures
    Lee, Han-Jun
    Kang, Ki-Ser Kang
    Kang, Soo-Yong
    Lee, Jae-Sung
    FOOT & ANKLE INTERNATIONAL, 2009, 30 (02) : 157 - 159
  • [28] Medial oblique compression fracture of the coronoid process of the ulna
    Sanchez-Sotelo, J
    O'Driscoll, SW
    Morrey, BF
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) : 60 - 64
  • [29] The pronator teres and the flexor carpi radialis interval approach for operative fixation of ulna coronoid process fractures
    Ni, Qubo
    Yang, Xu
    Pan, Zhengqi
    Wang, Jianping
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (02)
  • [30] FRACTURE OF THE CORONOID PROCESS OF THE ULNA REQUIRING REDUCTION IN EXTENSION
    TANZMAN, M
    KAUFMAN, B
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (05): : 741 - 742