Point-of-Care Ultrasound Transmission for Remote Interpretation in Austere Environments
被引:2
|
作者:
Haines, Carver M.
论文数: 0引用数: 0
h-index: 0
机构:
Virginia Tech, Caril Clin, Roanoke, VA USA
Virginia Tech, Family Med Wilderness Med, Caril Clin, Roanoke, VA 24061 USAVirginia Tech, Caril Clin, Roanoke, VA USA
Haines, Carver M.
[1
,2
]
Waasdorp, Christopher P.
论文数: 0引用数: 0
h-index: 0
机构:
Virginia Tech, Caril Clin, Roanoke, VA USAVirginia Tech, Caril Clin, Roanoke, VA USA
Waasdorp, Christopher P.
[1
]
Lockhart, Ellen R.
论文数: 0引用数: 0
h-index: 0
机构:
Virginia Tech, Caril Clin, Roanoke, VA USAVirginia Tech, Caril Clin, Roanoke, VA USA
Lockhart, Ellen R.
[1
]
Lareau, Stephanie A.
论文数: 0引用数: 0
h-index: 0
机构:
Virginia Tech, Caril Clin, Roanoke, VA USAVirginia Tech, Caril Clin, Roanoke, VA USA
Lareau, Stephanie A.
[1
]
机构:
[1] Virginia Tech, Caril Clin, Roanoke, VA USA
[2] Virginia Tech, Family Med Wilderness Med, Caril Clin, Roanoke, VA 24061 USA
Introduction-Point-of-care ultrasound (POCUS) is used in wilderness medicine and could potentially be the only imaging modality available. Cellular and data coverage is often lacking in remote areas, limiting image transmission. This study evaluates the viability of transmitting POCUS images from austere environments using slow-scan television (SSTV) image transmission methods over very-high-frequency (VHF) hand-held radio units for remote interpretation.Methods-Fifteen deidentified POCUS images were selected and encoded into an SSTV audio stream by a smartphone and transmitted over a VHF radio. A second radio and smartphone 1 to 5 mi away received and decoded the signals back into images. The original images and transmitted images were randomized into a survey graded by emergency medicine physicians using a standardized ultrasound quality assurance scoring scale (1-5 points).Results-The difference in mean scores between the original image and transmitted image showed a 3.9% decrease in transmitted image scores, with P <0.05 on a paired t test; however, this is not likely a clinically significant decrease. Comparing transmitted images using different SSTV encodings and distances ranging up to 5 mi, 100% of survey respondents determined the images to be clinically usable. This dropped to 75% when significant artifacts were introduced.Conclusions-Slow-scan television image transmission is a viable option for transmitting ultrasound images in remote areas where more modern forms of communication are unavailable or not practical. Slow-scan television may have potential as another data transmission option in the wilderness, such as electrocardiogram tracings.
机构:
Emory Univ, Sch Med, Dept Neurol, Neurocrit Care, Atlanta, GA USA
Emory Univ, Sch Med, 1364 E Clifton Rd, Atlanta, GA 30322 USAEmory Univ, Sch Med, Dept Neurol, Neurocrit Care, Atlanta, GA USA
Sigman, Erika J.
Laghari, Fahad J.
论文数: 0引用数: 0
h-index: 0
机构:
Carondelet Neurol Inst, Dept Neurosurg, Neuroendovascular Surg, Tucson, AZ USAEmory Univ, Sch Med, Dept Neurol, Neurocrit Care, Atlanta, GA USA
Laghari, Fahad J.
Sarwal, Aarti
论文数: 0引用数: 0
h-index: 0
机构:
Wake Forest Sch Med, Dept Neurol, Neurocrit Care, Winston Salem, NC USAEmory Univ, Sch Med, Dept Neurol, Neurocrit Care, Atlanta, GA USA
机构:
Univ Massachusetts, Med Sch, Dept Emergency Med, 55 Lake Ave North, Worcester, MA 01655 USAUniv Massachusetts, Med Sch, Dept Emergency Med, 55 Lake Ave North, Worcester, MA 01655 USA
Gleeson, Timothy
Blehar, David
论文数: 0引用数: 0
h-index: 0
机构:
Univ Massachusetts, Med Sch, Dept Emergency Med, 55 Lake Ave North, Worcester, MA 01655 USAUniv Massachusetts, Med Sch, Dept Emergency Med, 55 Lake Ave North, Worcester, MA 01655 USA
机构:
Univ Illinois, Coll Med Peoria, Dept Internal Med, Peoria, IL USA
530 NE Glen Oak Ave,North Bldg Room 5654, Peoria, IL 61637 USAUniv Calgary, Dept Med, Calgary, AB, Canada
机构:
Univ Calgary, Dept Med, 3330 Hosp Dr Northwest, Calgary, AB T2N 4N1, Canada
3330 Hosp Dr Northwest, Calgary, AB T2N 4N1, CanadaUniv Calgary, Dept Med, 3330 Hosp Dr Northwest, Calgary, AB T2N 4N1, Canada
Brockman, Nicole
Wong, Tanping
论文数: 0引用数: 0
h-index: 0
机构:
Weill Cornell Med Ctr, Sect Hosp Med, Dept Gen Internal Med, 525 East 68 St,Box 331, New York, NY 10065 USAUniv Calgary, Dept Med, 3330 Hosp Dr Northwest, Calgary, AB T2N 4N1, Canada
机构:
Harvard Med Sch, Massachusetts Gen Hosp, Emergency Ultrasound Fellowship, Boston, MA 02115 USAHarvard Med Sch, Massachusetts Gen Hosp, Emergency Ultrasound Fellowship, Boston, MA 02115 USA
Shokoohi, Hamid
Duggan, Nicole M.
论文数: 0引用数: 0
h-index: 0
机构:
Massachusetts Gen Hosp, Brigham & Womens Hosp, Dept Emergency Med, Harvard Affiliated Emergency Med Residency Progra, Boston, MA 02114 USAHarvard Med Sch, Massachusetts Gen Hosp, Emergency Ultrasound Fellowship, Boston, MA 02115 USA
Duggan, Nicole M.
Adhikari, Srikar
论文数: 0引用数: 0
h-index: 0
机构:
Univ Arizona, Emergency Ultrasound, Emergency Med, Tucson, AZ USAHarvard Med Sch, Massachusetts Gen Hosp, Emergency Ultrasound Fellowship, Boston, MA 02115 USA
Adhikari, Srikar
Selame, Lauren Ann
论文数: 0引用数: 0
h-index: 0
机构:
Massachusetts Gen Hosp, Dept Emergency Med, Emergency Ultrasound, Boston, MA 02114 USAHarvard Med Sch, Massachusetts Gen Hosp, Emergency Ultrasound Fellowship, Boston, MA 02115 USA
Selame, Lauren Ann
Amini, Richard
论文数: 0引用数: 0
h-index: 0
机构:
Univ Arizona, Dept Emergency Med, Tucson, AZ USAHarvard Med Sch, Massachusetts Gen Hosp, Emergency Ultrasound Fellowship, Boston, MA 02115 USA
Amini, Richard
Blaivas, Michael
论文数: 0引用数: 0
h-index: 0
机构:
Univ South Carolina, Dept Med, Columbia, SC USA
Soc Ultrasound Med Educ, Columbia, SC USAHarvard Med Sch, Massachusetts Gen Hosp, Emergency Ultrasound Fellowship, Boston, MA 02115 USA