Patient-Specific Orbital Implants Vs. Pre-Formed Implants for Internal Orbital Reconstruction

被引:0
|
作者
Prat, Daphna Landau [1 ,2 ,3 ,4 ,5 ,7 ]
Massarwa, Said [6 ]
Zohar, Assa [1 ]
Priel, Ayelet [1 ,3 ]
Sagiv, Oded [1 ,3 ]
Zloto, Ofira [1 ,2 ,3 ]
Ben Simon, Guy J. J. [1 ,2 ,3 ]
机构
[1] Sheba Med Ctr Tel Hashomer, Goldschleger Eye Inst, Orbital Ophthalm Plast & Lacrimal Surg Inst, Tel Hashomer, Israel
[2] Sheba Med Ctr Tel Hashomer, Sheba Talpiot Med Leadership Program, Tel Hashomer, Israel
[3] Tel Aviv Univ, Sackler Fac Med, Ramat Aviv, Israel
[4] Univ Penn, Childrens Hosp Philadelphia, Perelman Sch Med, Oculoplast & Orbital Surg Serv,Div Ophthalmol, Philadelphia, PA USA
[5] Univ Penn, Perelman Sch Med, Ctr Human Appearance, Edwin & Fannie Gray Hall, Philadelphia, PA USA
[6] Hadassah Hebrew Univ Hosp, Plast Surg Dept, Jerusalem, Israel
[7] Sheba Med Ctr, Orbital Ophthalm Plast & Lacrimal Surg Inst, IL-52621 Tel Hashomer, Israel
关键词
Orbital blowout fracture; Orbital fracture; Patient specific orbital implants;
D O I
10.1080/08820538.2023.2166353
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeTo compare the outcome of orbital blowout fracture repair by means of pre-formed porous-polyethylene titanium implants (PFI) vs patient-specific porous-polyethylene implants (PSI).MethodsRetrospective cohort study. Baseline characteristics, ophthalmic examination results, ocular motility, fracture type, the timing of surgery, implant type, and final relative enophthalmos of all patients operated on for blow-out fractures in a single center were collected and analyzed.ResultsTwenty-seven patients (mean age 39 years, 9 females) were enrolled. Sixteen underwent fracture repair with PFI and 11 with PSI at 11 months (median) post-trauma. Mean follow-up duration was 1.1 years. Both groups showed significant postoperative improvement in primary or vertical gaze diplopia (P = .03, chi(2)). Relative enophthalmos improved from -3.2 preoperative PFI to -1.7 mm postoperative PFI, and from -3.0 mm preoperative PSI to -1.1 mm postoperative PSI (P= .1). PSI patients had non-significantly less postoperative enophthalmos and globe asymmetry than PFI patients. The outcome was not influenced by previous surgery, age, sex, number of orbital walls involved in the initial trauma, or medial wall involvement (linear regression). Both groups sustained complications unrelated to implant choice.ConclusionBoth PSI and PFI yielded good outcomes in this study. PSI may be a good alternative to PFI in primary or secondary orbital blowout fracture repair with less enophthalmos and globe asymmetry, in spite of the possible disadvantages of production time, a relatively larger design, and challenging insertion. Since it is a mirror image of the uninjured orbit, it may be beneficial in extensive fractures.
引用
收藏
页码:365 / 370
页数:6
相关论文
共 50 条
  • [1] Patient-specific implants in orbital reconstruction
    Hajibandeh, Jeffrey
    Lee, Cameron
    CURRENT OPINION IN OTOLARYNGOLOGY & HEAD AND NECK SURGERY, 2022, 30 (04): : 230 - 235
  • [2] The Use of Patient-Specific Orbital Reconstruction Implants During Maxillectomy Reconstruction
    Desai, Dipan P. D.
    Alwani, Mohamedkazim
    Sheen, Derek
    Narayanan, Ajay
    Gordin, Eli
    FACIAL PLASTIC SURGERY & AESTHETIC MEDICINE, 2023, 25 (05) : 403 - 408
  • [3] Patient-Specific Orbital Implants: Development and Implementation of Technology for More Accurate Orbital Reconstruction
    Podolsky, Dale J.
    Mainprize, James G.
    Edwards, Glenn P.
    Antonyshyn, Oleh M.
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (01) : 131 - 133
  • [4] Surgical Outcomes of Orbital Fracture Reconstruction Using Patient-Specific Implants
    Blumer, Michael
    Essig, Harald
    Steigmiller, Klaus
    Wagner, Maximilian Eberhard
    Gander, Thomas
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 79 (06) : 1302 - 1312
  • [5] Validation of mixed reality in planning orbital reconstruction with patient-specific implants
    K. Dubron
    E. Shaheen
    R. Jacobs
    C. Politis
    R. Willaert
    Scientific Reports, 15 (1)
  • [6] Patient-specific Implants for Orbital Fractures: A Systematic Review
    Maher, Dominic, I
    Hall, Anthony J.
    Gwini, StellaMay
    Ben Artsi, Elad
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2022, 38 (05): : 417 - 424
  • [7] Do Patient-Specific Implants Decrease Complications and Increase Orbital Volume Reconstruction Accuracy in Primary Orbital Fracture Reconstruction?
    Timoshchuk, Mari-Alina
    Murnan, Eric J.
    Chapple, Andrew G.
    Christensen, Brian J.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2022, 80 (04) : 669 - 675
  • [8] Critical appraisal of patient-specific implants for secondary post-traumatic orbital reconstruction
    Schreurs, R.
    Klop, C.
    Gooris, P. J. J.
    Maal, T. J. J.
    Becking, A. G.
    Dubois, L.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2022, 51 (06) : 790 - 798
  • [9] Clinical application of automated virtual orbital reconstruction for orbital fracture management with patient-specific implants: A prospective comparative study
    Chepurnyi, Yurii
    Zhukovtseva, Olena
    Kopchak, Andriy
    Kanura, Oleksandr
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2022, 50 (09) : 686 - 691
  • [10] Utilizing 3D-Printed Orbital Floor Stamps to Create Patient-Specific Implants for Orbital Floor Reconstruction
    Prabhu, Shamit S.
    Chung, Scotty A.
    Brown, Philip J.
    Runyan, Christopher M.
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2021, 37 (01): : 81 - 85