An experimental study on gas-liquid two-phase countercurrent flow limitations of vertical pipes

被引:4
|
作者
Ma, Youfu [1 ]
Zeng, Shanshan [1 ]
Shao, Jie [1 ]
Zhou, Tuo [2 ]
Lyu, Junfu [2 ]
Li, Jingfen [3 ]
Lu, Peng [3 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai Key Lab Multiphase Flow & Heat Transfer P, Shanghai 200093, Peoples R China
[2] Tsinghua Univ, Dept Energy & Power Engn, Key Lab Thermal Sci & Power Engn, Minist Educ, Beijing 100084, Peoples R China
[3] Shanghai Marine Diesel Engine Res Inst, Shanghai 201108, Peoples R China
关键词
Gas-liquid flow; CCFL; Vertical pipe; Prediction model; Correlation; AIR-WATER; DUCTS;
D O I
10.1016/j.expthermflusci.2022.110789
中图分类号
O414.1 [热力学];
学科分类号
摘要
The gas-liquid two-phase countercurrent flow limitation (CCFL) of vertical pipes is an important subject of concern in various industries. Predicting the CCFL of vertical pipes, i.e. the flow rate relationship between the gas and liquid phases under CCFL conditions, has not yet been clearly determined on effects of the structural pa-rameters of the pipe. In this study, a visualization experiment on the CCFL of vertical pipes was performed by using air and water as the two phases. The effects of pipe diameter and pipe length were tested in the ranges of 25-100 mm and 0.50-2.0 m, respectively. Based on the experimental result, the flow behaviors of the CCFL in vertical pipes were analyzed, and four existing CCFL correlation models were examined in their capabilities to correlate the effects of pipe diameter and pipe length. The result shows that the flow patterns in vertical pipes are essentially annular flows and annular-mist flows under CCFL conditions, and the flow behaviors on gas-liquid interface present different features as the pipe differed in diameters. Examination of the available CCFL models indicates that none of them has reached a satisfactory correlation on the effects of pipe diameter and pipe length. Consequently, based on a reasonable fluid mechanics analysis, a novel CCFL correlation model that can correlate the effects of pipe diameter and pipe length was advanced. This model provides a reasonable and accurate prediction of the CCFL of vertical pipes when the pipe varies in structural parameters, which is of great sig-nificance to the safe and efficient operation of the related equipment in nuclear power generation, natural gas extraction and chemical industries.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Statistical characteristics of two-phase gas-liquid flow in a vertical microchannel
    I. A. Kozulin
    V. V. Kuznetsov
    Journal of Applied Mechanics and Technical Physics, 2011, 52 : 956 - 964
  • [22] Statistical characteristics of two-phase gas-liquid flow in a vertical microchannel
    Kozulin, I. A.
    Kuznetsov, V. V.
    JOURNAL OF APPLIED MECHANICS AND TECHNICAL PHYSICS, 2011, 52 (06) : 956 - 964
  • [23] Interfacial friction in upward annular gas-liquid two-phase flow in pipes
    Aliyu, Musa Aliyu
    Baba, Yahaya Danjuma
    Lao, Liyun
    Yeung, Hoi
    Kim, Kyung Chun
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 84 : 90 - 109
  • [24] Development of a fast transient simulator for gas-liquid two-phase flow in pipes
    Choi, Jinho
    Pereyra, Eduardo
    Sarica, Cem
    Lee, Hoyoung
    Jang, Il Sik
    Kang, JooMyoung
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2013, 102 : 27 - 35
  • [25] Modelling of stratified gas-liquid two-phase flow in horizontal circular pipes
    de Sampaio, Paulo A. B.
    Faccini, Jose L. H.
    Su, Jian
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2008, 51 (11-12) : 2752 - 2761
  • [26] Transient gas-liquid two-phase flow in pipes with radial influx or efflux
    Ouyang, LB
    Aziz, K
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2001, 30 (3-4) : 167 - 179
  • [27] Study on the vertical oscillatory gas-liquid two-phase flow and heat transfer characteristics
    Huang, Yuqi
    Chen, Haipeng
    Fang, Yidong
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 43
  • [28] Initiation conditions of liquid ascent of the countercurrent two-phase flow in vertical pipes (in the presence of two-phase mixture in the lower portion)
    Koizumi, Yasuo
    Ueda, Tatsuhiro
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1993, 59 (567): : 3537 - 3543
  • [29] Initiation conditions of liquid ascent of the countercurrent two-phase flow in vertical pipes (in the presence of two-phase mixture in the lower portion)
    Koizumi, Y
    Ueda, T
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1996, 22 (01) : 31 - 43
  • [30] Gas-liquid two-phase flow measure',ment with dual-plane ERT system in vertical pipes
    Tan Chao
    Dong Feng
    Hua Shuang
    Qi Guohua
    MULTIPHASE FLOW: THE ULTIMATE MEASUREMENT CHALLENGE, PROCEEDINGS, 2007, 914 : 734 - +