Investigations on a 2.2 K five-stage Stirling-type pulse tube cryocooler. Part A: Theoretical analyses and modeling

被引:2
|
作者
Tan, Han [1 ,3 ]
Tan, Jun [1 ]
Zhao, Bangjian [1 ,3 ]
Zhao, Yongjiang [1 ,3 ]
Xue, Renjun [1 ,3 ]
Wu, Shiguan [1 ,3 ]
Zhai, Yujia [1 ,3 ]
Wu, Dirui [1 ,3 ]
Ma, Dong [1 ,3 ]
Dang, Haizheng [1 ,2 ,3 ,4 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Tech Phys, State Key Lab Infrared Phys, 500 Yutian Rd, Shanghai 200083, Peoples R China
[2] Shanghai Res Ctr Quantum Sci, Shanghai 201315, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Shanghai Boreas Cryogen Co Ltd, Shanghai 201802, Peoples R China
基金
中国国家自然科学基金;
关键词
Five-stage Stirling-type pulse tube cryocooler; 2; K; Improved electrical circuit analogy model; Active phase compressor; Waveform synthesis method; Exergetic efficiency;
D O I
10.1016/j.cryogenics.2023.103630
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper conducts systematic theoretical analyses and modeling of a five-stage Stirling-type pulse tube cry-ocooler (SPTC) which is expected to directly reach a temperature of around 2 K and also to simultaneously achieve the cooling capacities at five temperatures varying from 2.2 K to 80 K for multiple uses. At the fourth stage it uses an active phase compressor (APC) to obtain the optimal phase relationship at the low temperatures below 12 K. A further improved electrical circuit analogy (ECA) model with the APC is developed to investigate the phase characteristics, loss mechanisms, and cooling performance of the last two stages. The structural design of the five-stage SPTC is described, in which a waveform synthesis method based on the impedance and phase analysis is proposed to clarify the effects of APC parameters on the pressure and flow in the regenerators of the last two stages. The impedance and dimensional parameters of both stages are optimized according to the system exergetic efficiency. The simulation results indicate that, with He-3, the system exergetic efficiency of the last two stages is expected to reach 2.39 %. It also indicates a five-stage SPTC alone has potential of reaching 2.2 K with simultaneously having the cooling capacities at five temperatures.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Investigation of a Stirling-type Pulse Tube Cryocooler with 100 W-class Cooling Power at 77 K
    Zhang, L. M.
    Hu, J. Y.
    Chen, Y. Y.
    Luo, E. C.
    Dai, W.
    ADVANCES IN CRYOGENIC ENGINEERING, 2014, 1573 : 1410 - 1416
  • [42] Numerical and experimental study on the characteristics of 4 K gas-coupled Stirling-type pulse tube cryocooler
    Chen Liubiao
    Wu Xianlin
    Liu Xuming
    Pan Changzhao
    Zhou Yuan
    Wang Junjie
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 88 : 204 - 210
  • [43] 13 K thermally coupled two-stage Stirling-type pulse tube refrigerator
    THUMMES Günter
    ChineseScienceBulletin, 2005, (16) : 144 - 146
  • [44] 13 K thermally coupled two-stage Stirling-type pulse tube refrigerator
    Tang, K
    Chen, GB
    Thummes, G
    CHINESE SCIENCE BULLETIN, 2005, 50 (16): : 1814 - 1816
  • [45] Study on a 5.0 W/80 K single stage Stirling type pulse tube cryocooler
    J.M.PFOTENHAUER
    Journal of Zhejiang University(Science A:An International Applied Physics & Engineering Journal), 2008, (09) : 1277 - 1282
  • [46] Study on a 5.0 W/80 K single stage Stirling type pulse tube cryocooler
    Zhi-hua Gan
    Guo-jun Liu
    Ying-zhe Wu
    Qiang Cao
    Li-min Qiu
    Guo-bang Chen
    J. M. Pfotenhauer
    Journal of Zhejiang University-SCIENCE A, 2008, 9 : 1277 - 1282
  • [47] Study on a 5.0 W/80 K single stage Stirling type pulse tube cryocooler
    Gan, Zhi-hua
    Liu, Guo-jun
    Wu, Ying-zhe
    Cao, Qiang
    Qiu, Li-min
    Chen, Guo-bang
    Pfotenhauer, J. M.
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2008, 9 (09): : 1277 - 1282
  • [48] Design and preliminary experimental investigation of a 4K Stirling-type pulse tube cryocooler with precooling附视频
    Zhihua GAN Zhuopei LI Jie CHEN Li DAI Limin QIU Institute of Refrigeration and Cryogenics Zhejiang University Hangzhou China
    Journal of Zhejiang University(Science A:An International Applied Physics & Engineering Journal), 2009, (09) : 1277 - 1284
  • [49] CFD simulation of a miniature coaxial Stirling-type pulse tube cryocooler operating at 128 Hz
    Zhao, Yibo
    Dang, Haizheng
    CRYOGENICS, 2016, 73 : 53 - 59
  • [50] Design of 4 K Stirling type pulse tube cryocooler with precooling
    Gan, Zhi-Hua
    Li, Zhuo-Pei
    Chen, Jie
    Qiu, Li-Min
    Dai, Li
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2009, 30 (03): : 378 - 380