Evaluation of the effect of cone beam computed tomography (CBCT) system in adaptive radiotherapy (ART) lung plans

被引:1
|
作者
Yanik, Ramiser [1 ]
Dirican, Bahar [1 ]
机构
[1] Univ Hlth Sci, Gulhane Fac Med, Dept Radiat Oncol, Ankara, Turkiye
关键词
Adaptive radiotherapy; Cone beam computed tomography; Lung cancer; Radiotoxicity;
D O I
10.1016/j.jrras.2024.100843
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Target volume and healthy lung tissue changes during radiotherapy may effect lung tissue -toxicity for patients with lung cancer. Shrinkage or upsizing of the tumor size may be seen during the course of conventionally fractionated radiotherapy course. Pre -radiotherapy Computed Tomography (CT) and Cone Beam CT (CBCT) images taken during -radiotherapy may be effectively used for Adaptive Radiotherapy (ART) of lung cancer patients. However, the reasonable time interval between CBCT imaging is important for consideration of tumor volume changes to achieve normal tissue sparing. Material and method: CBCT of twenty non -small cell lung cancer patients were retrospectively examined to evaluate the effectivity of 10th, 20th and 30th imaging days in establishing a better tumor coverage and healthy tissue sparing for shrinkage and upsizing conditions. The baseline treatment plan (pCT), 1st adaptive treatment plan (pCBCT1), 2nd adaptive treatment plan (pCBCT2), 3rd adaptive treatment plan (pCBCT3) were analyzed to determine changes in target and critical organs. Results: Wilcoxon signed -ranks test with Bon Ferroni correction was performed to determine which adaptive plan was different. A significant difference was found between pCT to pCBCT2; pCT to pCBCT3; pCBCT1 to pCBCT2; pCBCT1 to pCBCT3 in adaptive treatment plans for Lung-GTV (V20) and Lung-GTV (V5) (p value <= 0.05). A significant difference was found between pCT to pCBCT2; pCT to pCBCT3: pCBCT1 to pCBCT3 in adaptive treatment plans for Lung-GTV (MLD), Heart V (30), Heart V (45), Heart (mean), Esophagus (mean) and Brachial plexus (max) (p value <= 0.05). A significant difference was found between pCT to pCBCT1; pCT to pCBCT2; pCT to pCBCT3: pCBCT1 to pCBCT3 in adaptive treatment plans for Cord (max) (p value <= 0.05). A significant difference was found between pCT to pCBCT3 in adaptive treatment plans for Heart V (60) (p value <= 0.05) (Spss version 22). Conclusion: CBCT serves as an effective imaging tool for normal tissue sparing by adaptive lung cancer radiotherapy.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Cone Beam Computed Tomography (CBCT) in the Field of Interventional Oncology of the Liver
    Bapst, Blanche
    Lagadec, Matthieu
    Breguet, Romain
    Vilgrain, Valerie
    Ronot, Maxime
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 39 (01) : 8 - 20
  • [32] Cone-beam computed tomography (CBCT) for adaptive image guided head and neck radiation therapy
    Hvid, Christian A.
    Elstrom, Ulrik V.
    Jensen, Kenneth
    Grau, Cai
    ACTA ONCOLOGICA, 2018, 57 (04) : 552 - 556
  • [33] A novel evaluation model of image registration for cone-beam computed tomography guided lung cancer radiotherapy
    Liu, Yimei
    Chen, Meining
    Fang, Jianlan
    Xiao, Liangjie
    Liu, Songran
    Li, Qiwen
    Qiu, Bo
    Huang, Runda
    Zhang, Jun
    Peng, Yinglin
    THORACIC CANCER, 2024, 15 (17) : 1333 - 1342
  • [34] Cone Beam Computed Tomography (CBCT) in the Field of Interventional Oncology of the Liver
    Blanche Bapst
    Matthieu Lagadec
    Romain Breguet
    Valérie Vilgrain
    Maxime Ronot
    CardioVascular and Interventional Radiology, 2016, 39 : 8 - 20
  • [35] Megavoltage and Kilovoltage Cone-Beam Computed Tomography Image Guidance for Lung Radiotherapy
    Vlad, M.
    Sixel, K.
    Kosowan, S.
    Hart, M.
    Iqbal, F.
    El-Mallah, M.
    Vandermeer, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [36] FRAMELESS STEREOTACTIC BODY RADIOTHERAPY FOR LUNG TUMOURS WITH AN INTRAFRACTION CONE BEAM COMPUTED TOMOGRAPHY
    Gopaul, D.
    Schaly, B.
    Panjwani, D.
    Jiang, R.
    Mills, A.
    Kelly, N.
    Barnet, R.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S57 - S57
  • [37] Evaluation of the Effect of Topical Melatonin Application on Immediately Placed Dental Implants Using Cone Beam Computed Tomography (CBCT)
    Kiran, Sunkavilli Ravi
    Bammidi, Niharika
    Kumar, Avula Kishan
    Kumar, Peruri Santosh
    Karnam, Yudheera
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (05)
  • [38] Cone-Beam Computed Tomography (CBCT) Versus CT in Lung Ablation Procedure: Which is Faster?
    Cazzato, Roberto Luigi
    Battistuzzi, Jean-Benoit
    Catena, Vittorio
    Grasso, Rosario Francesco
    Zobel, Bruno Beomonte
    Schena, Emiliano
    Buy, Xavier
    Palussiere, Jean
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (05) : 1231 - 1236
  • [39] Cone-Beam Computed Tomography (CBCT) to Computed Tomography (CT) Image Translation with Perceptual Loss to Eliminate Cone-Beam Artifacts
    Yoo, S.
    Choi, B.
    Park, I.
    Kim, J.
    Kim, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [40] Cone-Beam Computed Tomography (CBCT) Versus CT in Lung Ablation Procedure: Which is Faster?
    Roberto Luigi Cazzato
    Jean-Benoit Battistuzzi
    Vittorio Catena
    Rosario Francesco Grasso
    Bruno Beomonte Zobel
    Emiliano Schena
    Xavier Buy
    Jean Palussiere
    CardioVascular and Interventional Radiology, 2015, 38 : 1231 - 1236