A weighted average mixed feedback control method based on LCL-type grid-connected inverter

被引:0
|
作者
Li, Yulong [1 ]
Yang, Ming [1 ]
Yang, Zhuo [1 ]
Zhu, Jun [1 ]
机构
[1] Henan Polytech Univ, Sch Elect Engn & Automat, Henan Key Lab Intelligent Detect & Control Coal Mi, Jiaozuo, Peoples R China
基金
中国国家自然科学基金;
关键词
digital control delay; grid-connected inverter; passivity theory; weak grid; weighted average current; OPTIMAL-DESIGN; FILTERS;
D O I
10.1002/cta.3798
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The weighted average current (WAC) control method has gained recognition for its order reduction characteristics and broad control bandwidth. However, the interaction of digital control delay and grid impedance introduces an inverse resonance peak in the system loop gain, challenging the order reduction properties of conventional WAC control and system passivity across a wide frequency range. Conventional approaches, such as lead compensator-based delay compensation or weighting coefficient redesign, improve system stability to some extent but fail to retain order reduction characteristics. To address these limitations, this article proposes a new control method known as weighted average mixed feedback, incorporating distinct voltage feedforward paths. By introducing a voltage feedback path, the proposed method reconfigures the system's zero positions, enabling the pole-zero cancelation in the open-loop characteristics independent of grid impedance. Additionally, this supplementary path offers impedance reshaping capabilities, enhancing system passivity and adaptability to weak grids. The effectiveness of the proposed control method is verified through simulations and experiments. This paper presents an improved weighted average current (WAC) control method for grid-connected inverters. This method addresses the limitation of the conventional WAC control method, which fails to achieve reduced-order control of the open-loop transfer function when considering the combined impact of digital control and grid impedance. Additionally, this control method significantly enhances the system's passivity, ensuring stability.image
引用
收藏
页码:723 / 748
页数:26
相关论文
共 50 条
  • [21] Design and control of an LCL-type single-phase grid-connected inverter with inverter current feedback using the phase-delay method
    Evran, Fatih
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2019, 27 (06) : 4702 - 4714
  • [22] Control Design of LCL Type Grid-Connected Inverter Based on State Feedback Linearization
    Yang, Longyue
    Feng, Chunchun
    Liu, Jianhua
    ELECTRONICS, 2019, 8 (08)
  • [23] Wide Damping Region for LCL-Type Grid-Connected Inverter With an Improved Capacitor-Current-Feedback Method
    Li, Xiaoqiang
    Wu, Xiaojie
    Geng, Yiwen
    Yuan, Xibo
    Xia, Chenyang
    Zhang, Xue
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (09) : 5247 - 5259
  • [24] Investigation of Reducing the Influence of Digital Control Delay to LCL-Type Grid-Connected Inverter
    Zhao, Guoshu
    Ma, Junyang
    Huang, Liuliu
    Tang, Yu
    2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2016,
  • [25] An Adaptive Proportional Feedforward Scheme for LCL-Type Grid-Connected Inverter
    Qin, Kuang
    Wang, Wentao
    Wang, Xuehua
    He, Yuying
    Ruan, Xinbo
    Liu, Fuxin
    2020 THIRTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2020), 2020, : 3287 - 3292
  • [26] A robust time delay compensated grid-connected control method for LCL-type inverter and stability analysis
    Yang, Ling
    Luo, An
    Chen, Yandong
    Zhou, Leming
    Huai, Kunshan
    Dianwang Jishu/Power System Technology, 2015, 39 (11): : 3102 - 3108
  • [27] Current Harmonic Analysis of Multisampled LCL-Type Grid-connected Inverter
    He, Shan
    Pan, Yiwei
    Zhou, Dao
    Wang, Xiongfei
    Blaabjerg, Frede
    2020 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2020, : 4329 - 4335
  • [28] Phase-angle compensation control of LCL-type grid-connected inverter based on impendance analysis
    Yang, Xingwu
    Wang, Nannan
    Wang, Yi
    Zhou, Bin
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (05): : 312 - 318
  • [29] Active Disturbance Rejection Control Based Single Current Feedback Resonance Damping Strategy for LCL-Type Grid-Connected Inverter
    Ma, Wenjie
    Guan, Yuanpeng
    Zhang, Bo
    Wu, Lihao
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2021, 36 (01) : 48 - 62
  • [30] Robust Delay Compensation Strategy for LCL-Type Grid-Connected Inverter in Weak Grid
    Ding, Xin
    Xue, Ruinan
    Zheng, Tianzhi
    Kong, Fannie
    Chen, Yanming
    IEEE ACCESS, 2022, 10 : 67639 - 67652