On-Field Test of Tuberculosis Diagnosis through Exhaled Breath Analysis with a Gas Sensor Array

被引:13
|
作者
Mougang, Yolande Christelle Ketchanji [1 ]
Mangamba, Laurent-Mireille Endale [2 ,3 ]
Capuano, Rosamaria [1 ,4 ]
Ciccacci, Fausto [5 ]
Catini, Alexandro [1 ,4 ]
Paolesse, Roberto [4 ,6 ]
Ngahane, Hugo Bertrand Mbatchou [2 ,7 ]
Palombi, Leonardo [8 ]
Di Natale, Corrado [1 ,4 ]
机构
[1] Univ Roma Tor Vergata, Dept Elect Engn, Via Politecn 1, I-00133 Rome, Italy
[2] Univ Douala, Fac Med & Pharmaceut Sci, POB 4035, Douala, Cameroon
[3] Douala Laquintinie Hosp, Ctr Resp Dis, Ave Jamot,POB 4035, Douala, Cameroon
[4] Univ Roma Tor Vergata, Interdept Ctr Volatil A DAmico, Via Politecn 1, I-00133 Rome, Italy
[5] St Camillus Int Univ Hlth & Med Sci, UniCamillus, I-00131 Rome, Italy
[6] Univ Roma Tor Vergata, Dept Chem Sci & Technol, Via Ric Sci, I-00133 Rome, Italy
[7] Douala Gen Hosp, Internal Med Serv, POB 4856, Douala, Cameroon
[8] Univ Roma Tor Vergata, Dept Biomed & Prevent, Viale Montpellier 1, I-00133 Rome, Italy
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 05期
关键词
tuberculosis (TB); breath analysis; volatile organic compounds (VOCs); electronic nose; PULMONARY TUBERCULOSIS; MASS-SPECTROMETRY; SENSITIVITY; POINT; NOSE;
D O I
10.3390/bios13050570
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tuberculosis (TB) is among the more frequent causes of death in many countries. For pulmonary TB, early diagnosis greatly increases the efficiency of therapies. Although highly sensitive tests based on nucleic acid amplification tests (NAATs) and loop-mediated isothermal amplification (TB-LAMP) are available, smear microscopy is still the most widespread diagnostics method in most low-middle-income countries, and the true positive rate of smear microscopy is lower than 65%. Thus, there is a need to increase the performance of low-cost diagnosis. For many years, the use of sensors to analyze the exhaled volatile organic compounds (VOCs) has been proposed as a promising alternative for the diagnosis of several diseases, including tuberculosis. In this paper, the diagnostic properties of an electronic nose (EN) based on sensor technology previously used to identify tuberculosis have been tested on-field in a Cameroon hospital. The EN analyzed the breath of a cohort of subjects including pulmonary TB patients (46), healthy controls (38), and TB suspects (16). Machine learning analysis of the sensor array data allows for the identification of the pulmonary TB group with respect to healthy controls with 88% accuracy, 90.8% sensitivity, 85.7% specificity, and 0.88 AUC. The model trained with TB and healthy controls maintains its performance when it is applied to symptomatic TB suspects with a negative TB-LAMP. These results encourage the investigation of electronic noses as an effective diagnostic method for future inclusion in clinical practice.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Analysis of volatile organic compounds in exhaled breath for lung cancer diagnosis using a sensor system
    Chang, Ji-Eun
    Lee, Dae-Sik
    Ban, Sang-Woo
    Oh, Jaeho
    Jung, Moon Youn
    Kim, Seung-Hwan
    Park, SungJoon
    Persaud, Krishna
    Jheon, Sanghoon
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 800 - 807
  • [22] Lung cancer detection in perioperative patients' exhaled breath with nanomechanical sensor array
    Saeki, Yusuke
    Maki, Naoki
    Nemoto, Takahiro
    Inada, Katsushige
    Minami, Kosuke
    Tamura, Ryo
    Imamura, Gaku
    Cho-Isoda, Yukiko
    Kitazawa, Shinsuke
    Kojima, Hiroshi
    Yoshikawa, Genki
    Sato, Yukio
    LUNG CANCER, 2024, 190
  • [23] Exhaled Breath Analysis for the Diagnosis of Obstructive Sleep Apnea
    Fabius, Timon M.
    De Vries, Rianne
    Brusse-Keizer, Marjolein
    Eijsvogel, Michiel M. M.
    De Jongh, Frans H. C.
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [24] Analyzing organic vapors in exhaled breath using a SAW sensor array with preconcentration
    Groves, WA
    Frye, GC
    Zellers, ET
    PROCEEDINGS OF THE SYMPOSIUM ON CHEMICAL AND BIOLOGICAL SENSORS AND ANALYTICAL ELECTROCHEMICAL METHODS, 1997, 97 (19): : 179 - 190
  • [25] Preparation of exhaled breath condensate for pH and gas analysis
    Vlasic, Z.
    Cepelak, I.
    Plavec, D.
    Turkalj, M.
    Nogalo, B.
    Zimic, L.
    Dodig, S.
    ACTA PAEDIATRICA, 2007, 96 : 214 - 214
  • [26] Detection of acetone in exhaled breath with the use of micropreconcentrator and a commercial gas sensor
    Michon, Dagmara
    Rydosz, Artur
    Domanski, Krzysztof
    Maziarz, Wojciech
    Pisarkiewicz, Tadeusz
    ELECTRON TECHNOLOGY CONFERENCE 2016, 2016, 10175
  • [27] Diagnosis of pulmonary tuberculosis and assessment of treatment response through analyses of volatile compound patterns in exhaled breath samples
    Zetola, Nicola M.
    Modongo, Chawangwa
    Matsiri, Ogopotse
    Tamuhla, Tsaone
    Mbongwe, Bontle
    Matlhagela, Keikantse
    Sepako, Enoch
    Catini, Alexandro
    Sirugo, Giorgio
    Martinelli, Eugenio
    Paolesse, Roberto
    Di Natale, Corrado
    JOURNAL OF INFECTION, 2017, 74 (04) : 367 - 376
  • [28] Diagnosis of COVID-19 by Exhaled Breath Analysis Using Gas Chromatography Mass Spectrometry
    Ibrahim, W.
    Cordell, R.
    Wilde, M. J.
    Richardson, M.
    Carr, L.
    Free, R.
    Monks, P.
    Brightling, C. E.
    Greening, N. J.
    Siddiqui, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)
  • [29] Exhaled Breath Analysis: From Laboratory Test to Wearable Sensing
    Heng, Wenzheng
    Yin, Shukun
    Chen, Yonglin
    Gao, Wei
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2025, 18 : 50 - 73
  • [30] COPD diagnosis by a gas sensor array
    Capuano, R.
    Santonico, M.
    Martinelli, E.
    Pennazza, G.
    Paolesse, R.
    Bergamini, A.
    Cazzola, M.
    Ciaprini, C.
    Di Natale, C.
    D'Amico, A.
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 484 - 487