Mechanism of load introduction and transfer within steel-encased concrete-filled steel tube connections

被引:5
|
作者
Song, Sha-Sha [1 ]
Xu, Fei [2 ]
Chen, Ju [1 ]
Wang, Yu-hang [2 ]
机构
[1] Zhejiang Univ, Inst Struct Engn, Hangzhou, Zhejiang, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, Key Lab New Technol Construction Cities Mt Area, Minist Educ, Chongqing, Peoples R China
基金
中国国家自然科学基金;
关键词
Concrete-filled steel tube; Design; K-type connection; Load transfer; Load introduction; Steel-encased; K-JOINTS; TUBULAR COLUMN; CHS BRACE; BEHAVIOR; PERFORMANCE; DESIGN; FRACTURE; MEMBERS;
D O I
10.1016/j.jcsr.2023.107818
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper studies the load introduction and transfer mechanisms for steel-encased concrete-filled steel tube (CFST) K-type connections experimentally and numerically. Six K-type CFST connections with encased built-up latticed angles were tested. The finite element (FE) models were established and verified by the experimental results. Effectiveness of the reinforcing plates, i.e., direct bearing in an extended range was evaluated based on the parametric analysis. The upper chord length of 2D mm is sufficient to transfer the required load from the chord wall to inner concrete via the direct shear interaction only. Though employing insufficient confinement provided by the chord wall, the chord with non-compact and slender sections cannot fully transfer the required load, even if the reinforcing plates are adopted. In general, due to the non-uniformed load introduction from single-side braces in K-type CFST connections, the reinforcing plates cannot effectively provide direct bearing to the inner concrete due to the localised stress effect and plying force. Furthermore, the ability of load transfer in the interface of inner concrete and encased angles should be ensured to achieve full utilisation of angle strengths. Finally, the equations for the lengths of load introduction between the tube-concrete and concrete-angle interfaces were proposed according to the numerical results. The comparison with the numerical results demonstrates that the proposed equations can predict load introduction lengths accurately and reliably.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Flexural Performance of High-strength Prestressed Concrete-encased Concrete-filled Steel Tube Sections
    Rahmani, Z.
    Naghipour, M.
    Nematzadeh, M.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2019, 32 (09): : 1238 - 1247
  • [32] Shear behavior of concrete-encased square concrete-filled steel tube members: Experiments and strength prediction
    Yang, Yong
    Chen, Xin
    Xue, Yicong
    Yu, Yunlong
    Zhang, Chaorui
    STEEL AND COMPOSITE STRUCTURES, 2021, 38 (04): : 431 - 445
  • [33] Seismic performance of concrete-encased column base for hexagonal concrete-filled steel tube: experimental study
    Xu, Wu
    Han, Lin-Hai
    Li, Wei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 121 : 352 - 369
  • [34] Circular concrete-encased concrete-filled steel tube (CFST) stub columns subjected to axial compression
    Li, Yong-Jin
    Han, Lin-Hai
    Xu, Wu
    Tao, Zhong
    MAGAZINE OF CONCRETE RESEARCH, 2016, 68 (19) : 995 - 1010
  • [35] Flexural behavior of square concrete-encased concrete-filled double-skin steel tube members
    Li, Minglun
    Ren, Qingxin
    Wang, Qinghe
    Ding, Jinan
    Structures, 2024, 60
  • [36] Seismic performance of concrete-encased column base for hexagonal concrete-filled steel tube: numerical study
    Han, Lin-Hai
    Hou, Chuan-Chuan
    Xu, Wu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 149 : 225 - 238
  • [37] Quasi-static cyclic load performance of encased concrete-filled steel tubular with steel loops joint using sustainable concrete
    Aravind Raj P.S.
    Divahar R.
    Sangeetha S.P.
    Joanna P.S.
    Asian Journal of Civil Engineering, 2020, 21 (7) : 1259 - 1267
  • [38] Flexural behavior of square concrete-encased concrete-filled double-skin steel tube members
    Li, Minglun
    Ren, Qingxin
    Wang, Qinghe
    Ding, Jinan
    STRUCTURES, 2024, 60
  • [39] Prefabricated connection for steel beam and concrete-filled steel tube column
    Ding, Chenting
    Pan, Xuebei
    Bai, Yu
    Shi, Gang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 162
  • [40] Impact behavior of concrete-filled steel tube with cruciform reinforcing steel under lateral impact load
    Zhu, Xiang
    Kang, Miao
    Fei, Yifan
    Zhang, Qi
    Wang, Rui
    ENGINEERING STRUCTURES, 2021, 247