共 50 条
Proof of concept: Shape-sensing robotic-assisted bronchoscopy performed under moderate sedation
被引:2
|作者:
Donna, Elio
[1
]
Wu, Steven
[2
,3
]
Arias, Sixto
[1
]
机构:
[1] Univ Miami Hlth Syst, Div Pulm & Crit Care Med, Sect Intervent Pulmonol, Miami, FL USA
[2] Univ Miami Hlth Syst, Jackson Mem Hosp, Dept Pulm & Crit Care Med, Miami, FL USA
[3] Univ Miami Hlth Syst, Dept Pulm & Crit Care, 1321 Northwest 14th St, Suite 204, Miami, FL 33176 USA
关键词:
ANESTHESIA;
D O I:
10.1016/j.rmcr.2022.101787
中图分类号:
R56 [呼吸系及胸部疾病];
学科分类号:
摘要:
We describe a first reported case of shape-sensing robotic-assisted bronchoscopy using ION-intuitive platform done successfully under moderate se-dation. A 76-year-old woman was found to have a right upper lobe mass measuring 3 x 2.9 cm. Diagnostic robotic navigational bronchoscopy was successfully performed under moderate sedation. Pathologic examination later revealed adenocarcinoma consistent with primary pulmonary malig-nancy. Conscious sedation allows the use of robotic bronchoscopy with minimal CT-to-body divergence and systems error. Robotic bronchoscopy un-der moderate sedation is feasible and seems to be safe and can be done without immediate complications.
引用
收藏
页数:3
相关论文