Economic analysis of remote monitoring in patients with implantable cardioverter defibrillators or cardiac resynchronization therapy defibrillators in the Trento area, Italy

被引:2
|
作者
Marini, Massimiliano [1 ]
Videsott, Lodovica [1 ]
Dalle Fratte, Chiara Francesca [2 ]
Francesconi, Andrea [3 ]
Bonvicini, Eleonora [1 ]
Quintarelli, Silvia [1 ]
Martin, Marta [1 ]
Guarracini, Fabrizio [1 ]
Coser, Alessio [1 ]
Benetollo, Pier Paolo [2 ]
Bonmassari, Roberto [1 ]
Boriani, Giuseppe [4 ]
机构
[1] Santa Chiara Hosp, Dept Cardiol, Trento, Italy
[2] APSS Azienda Prov & Serv Sanit, Controlling Dept, Trento, Italy
[3] Univ Trento, Dept Management & Econ, Trento, Italy
[4] Univ Modena & Reggio Emilia, Dept Biomed Metab & Neural Sci, Cardiol Div, Policlin Modena, Modena, Italy
来源
关键词
remote monitoring; heart failure; hf; cardiac implantable electronic device; CIED; Italy; HEART-FAILURE; ELECTRONIC DEVICES; CARE; ARRHYTHMOLOGY; ASSOCIATION;
D O I
10.3389/fcvm.2023.1151167
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionRemote monitoring (RM) technologies have the potential to improve patient care by increasing compliance, providing early indications of heart failure (HF), and potentially allowing for therapy optimization to prevent HF admissions. The aim of this retrospective study was to assess the clinical and economic consequences of RM vs. standard monitoring (SM) through in-office cardiology visits, in patients carrying a cardiac implantable electronic device (CIED). MethodsClinical and resource consumption data were extracted from the Electrophysiology Registry of the Trento Cardiology Unit, which has been systemically collecting patient information from January 2011 to February 2022. From a clinical standpoint, survival analysis was conducted, and incidence of cardiovascular (CV) related hospitalizations was measured. From an economic standpoint, direct costs of RM and SM were collected to compare the cost per treated patient over a 2-year time horizon. Propensity score matching (PSM) was used to reduce the effect of confounding biases and the unbalance of patient characteristics at baseline. ResultsIn the enrollment period, N = 402 CIED patients met the inclusion criteria and were included in the analysis (N = 189 patients followed through SM; N = 213 patients followed through RM). After PSM, comparison was limited to N = 191 patients in each arm. After 2-years follow-up since CIED implantation, mortality rate for any cause was 1.6% in the RM group and 19.9% in the SM group (log-rank test, p < 0.0001). Also, a lower proportion of patients in the RM group (25.1%) were hospitalized for CV-related reasons, compared to the SM group (51.3%; p < 0.0001, two-sample test for proportions). Overall, the implementation of the RM program in the Trento territory was cost-saving in both payer and hospital perspectives. The investment required to fund RM (a fee for service in the payer perspective, and staffing costs for hospitals), was more than offset by the lower rate of hospitalizations for CV-related disease. RM adoption generated savings of -euro4,771 and -euro6,752 per patient in 2 years, in the payer and hospital perspective, respectively. ConclusionRM of patients carrying CIED improves short-term (2-years) morbidity and mortality risks, compared to SM and reduces direct management costs for both hospitals and healthcare services.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Causes of death and mortality in patients with implantable cardioverter defibrillators with and without cardiac resynchronization therapy
    Pournaras, A.
    Kader, R.
    Mattsson, G.
    Magnusson, P.
    EUROPEAN HEART JOURNAL, 2018, 39 : 1228 - 1229
  • [22] Cardiac resynchronization therapy reduces the need for shocks in patients with automated implantable cardioverter defibrillators
    Segerson, NM
    Bader, FM
    Walker, S
    Freedman, RA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 17A - 17A
  • [23] Remote interrogation and monitoring of implantable cardioverter defibrillators
    Joseph, GK
    Wilkoff, BL
    Dresing, T
    Burkhardt, J
    Khaykin, Y
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2004, 11 (02) : 161 - 166
  • [24] Manual vs. automatic capture management in implantable cardioverter defibrillators and cardiac resynchronization therapy defibrillators
    Murgatroyd, Francis D.
    Helmling, Erhard
    Lemke, Bernd
    Eber, Bernd
    Mewis, Christian
    van der Meer-Hensgens, Judith
    Chang, Yanping
    Khalameizer, Vladimir
    Katz, Amos
    EUROPACE, 2010, 12 (06): : 811 - 816
  • [25] Cardiac Implantable Electronic Device Therapy Permanent Pacemakers, Implantable Cardioverter Defibrillators, and Cardiac Resynchronization Devices
    Steffen, Melanie M.
    Osborn, Jeffery S.
    Cutler, Michael J.
    MEDICAL CLINICS OF NORTH AMERICA, 2019, 103 (05) : 931 - +
  • [26] Assessment of a remote monitoring system for implantable cardioverter defibrillators
    Masella, Cristina
    Zanaboni, Paolo
    Di Stasi, Francesca
    Gilardi, Serena
    Ponzi, Patrizia
    Valsecchi, Sergio
    JOURNAL OF TELEMEDICINE AND TELECARE, 2008, 14 (06) : 290 - 294
  • [27] Radiation therapy in patients with cardiac pacemakers or implantable cardioverter defibrillators
    Dorenkamp, M.
    Stromberger, C.
    von Heymann, C.
    Haverkamp, W.
    Wust, P.
    Roser, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (01) : 5 - 17
  • [28] Initial experience in the remote monitoring of implantable cardioverter defibrillators
    Affolter, J. T.
    Redfem, C.
    Patel, J. C.
    Lewis, A.
    Broadhurst, P. A.
    SCOTTISH MEDICAL JOURNAL, 2008, 53 (02) : 57 - 57
  • [29] ANALYSIS OF INAPPROPRIATE THERAPY IN THE PATIENTS IMPLANTABLE CARDIOVERTER DEFIBRILLATORS
    Wang Hui
    Qu Baiming
    Wu Lixuan
    HEART, 2010, 96 : A175 - A175
  • [30] Impact of COVID-19 lockdown in patients with implantable cardioverter and cardiac resynchronization therapy defibrillators: insights from daily remote monitoring transmissions
    Giosuè Mascioli
    Elena Lucca
    Paola Napoli
    Daniele Giacopelli
    Heart and Vessels, 2021, 36 : 1694 - 1700