Economic analysis of remote monitoring in patients with implantable cardioverter defibrillators or cardiac resynchronization therapy defibrillators in the Trento area, Italy

被引:2
|
作者
Marini, Massimiliano [1 ]
Videsott, Lodovica [1 ]
Dalle Fratte, Chiara Francesca [2 ]
Francesconi, Andrea [3 ]
Bonvicini, Eleonora [1 ]
Quintarelli, Silvia [1 ]
Martin, Marta [1 ]
Guarracini, Fabrizio [1 ]
Coser, Alessio [1 ]
Benetollo, Pier Paolo [2 ]
Bonmassari, Roberto [1 ]
Boriani, Giuseppe [4 ]
机构
[1] Santa Chiara Hosp, Dept Cardiol, Trento, Italy
[2] APSS Azienda Prov & Serv Sanit, Controlling Dept, Trento, Italy
[3] Univ Trento, Dept Management & Econ, Trento, Italy
[4] Univ Modena & Reggio Emilia, Dept Biomed Metab & Neural Sci, Cardiol Div, Policlin Modena, Modena, Italy
来源
关键词
remote monitoring; heart failure; hf; cardiac implantable electronic device; CIED; Italy; HEART-FAILURE; ELECTRONIC DEVICES; CARE; ARRHYTHMOLOGY; ASSOCIATION;
D O I
10.3389/fcvm.2023.1151167
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionRemote monitoring (RM) technologies have the potential to improve patient care by increasing compliance, providing early indications of heart failure (HF), and potentially allowing for therapy optimization to prevent HF admissions. The aim of this retrospective study was to assess the clinical and economic consequences of RM vs. standard monitoring (SM) through in-office cardiology visits, in patients carrying a cardiac implantable electronic device (CIED). MethodsClinical and resource consumption data were extracted from the Electrophysiology Registry of the Trento Cardiology Unit, which has been systemically collecting patient information from January 2011 to February 2022. From a clinical standpoint, survival analysis was conducted, and incidence of cardiovascular (CV) related hospitalizations was measured. From an economic standpoint, direct costs of RM and SM were collected to compare the cost per treated patient over a 2-year time horizon. Propensity score matching (PSM) was used to reduce the effect of confounding biases and the unbalance of patient characteristics at baseline. ResultsIn the enrollment period, N = 402 CIED patients met the inclusion criteria and were included in the analysis (N = 189 patients followed through SM; N = 213 patients followed through RM). After PSM, comparison was limited to N = 191 patients in each arm. After 2-years follow-up since CIED implantation, mortality rate for any cause was 1.6% in the RM group and 19.9% in the SM group (log-rank test, p < 0.0001). Also, a lower proportion of patients in the RM group (25.1%) were hospitalized for CV-related reasons, compared to the SM group (51.3%; p < 0.0001, two-sample test for proportions). Overall, the implementation of the RM program in the Trento territory was cost-saving in both payer and hospital perspectives. The investment required to fund RM (a fee for service in the payer perspective, and staffing costs for hospitals), was more than offset by the lower rate of hospitalizations for CV-related disease. RM adoption generated savings of -euro4,771 and -euro6,752 per patient in 2 years, in the payer and hospital perspective, respectively. ConclusionRM of patients carrying CIED improves short-term (2-years) morbidity and mortality risks, compared to SM and reduces direct management costs for both hospitals and healthcare services.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems
    Werner Jung
    Andreas Rillig
    Ralf Birkemeyer
    Tomislav Miljak
    Udo Meyerfeldt
    Journal of Interventional Cardiac Electrophysiology, 2008, 23 : 73 - 85
  • [2] Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems
    Jung, Werner
    Rillig, Andreas
    Birkemeyer, Ralf
    Miljak, Tomislav
    Meyerfeldt, Udo
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2008, 23 (01) : 73 - 85
  • [3] Eligibility of cardiac resynchronization therapy patients for subcutaneous implantable cardioverter defibrillators
    Giammaria, Massimo
    Lucciola, Maria Teresa
    Amellone, Claudia
    Orlando, Fabrizio
    Mazzone, Giuseppe
    Chiarenza, Sara
    Lovecchio, Mariolina
    Valsecchi, Sergio
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2019, 54 (01) : 49 - 54
  • [4] Implantable cardioverter defibrillators and devices for cardiac resynchronization therapy: what perspective for patients' apps combined with remote monitoring?
    Sgreccia, Daria
    Mauro, Erminio
    Vitolo, Marco
    Manicardi, Marcella
    Valenti, Anna Chiara
    Imberti, Jacopo Francesco
    Ziacchi, Matteo
    Boriani, Giuseppe
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (02) : 155 - 160
  • [5] Eligibility of cardiac resynchronization therapy patients for subcutaneous implantable cardioverter defibrillators
    Moubarak, Ghassan
    Maison-Blanche, Pierre
    Thomas, Olivier
    JOURNAL OF ELECTROCARDIOLOGY, 2018, 51 (03) : 531 - 533
  • [6] Eligibility of cardiac resynchronization therapy patients for subcutaneous implantable cardioverter defibrillators
    Massimo Giammaria
    Maria Teresa Lucciola
    Claudia Amellone
    Fabrizio Orlando
    Giuseppe Mazzone
    Sara Chiarenza
    Mariolina Lovecchio
    Sergio Valsecchi
    Journal of Interventional Cardiac Electrophysiology, 2019, 54 : 49 - 54
  • [7] Implantable Cardioverter-Defibrillators and Cardiac Resynchronization Therapy in Women
    Ignaszewski, Maya T.
    Daugherty, Stacie L.
    Russo, Andrea M.
    HEART FAILURE CLINICS, 2019, 15 (01) : 109 - +
  • [8] Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators
    Alam, Mian Bilal
    Munir, Muhammad Bilal
    Rattan, Rohit
    Flanigan, Susan
    Adelstein, Evan
    Jain, Sandeep
    Saba, Samir
    EUROPACE, 2014, 16 (02): : 246 - 251
  • [9] Remote Monitoring of Implantable Cardioverter Defibrillators
    Dilaveris, Polychronis
    Piotrowicz, Ryszard
    HELLENIC JOURNAL OF CARDIOLOGY, 2014, 55 (01) : 1 - 3
  • [10] Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: Analysis of a worldwide database
    Lazarus, Arnaud
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 : S2 - S12