FOLDABLE POLYMER STENT INTEGRATED WITH WIRELESS PRESSURE SENSOR FOR BLOOD PRESSURE MONITORING

被引:0
|
作者
Oyunbaatar, Nomin-Erdene [1 ]
Lee, Dong-Weon [1 ,2 ,3 ]
机构
[1] Chonnam Natl Univ, Dept Mech Engn, Gwangju, South Korea
[2] Chonnam Natl Univ, Ctr Next Generat Sensor Res & Dev, Gwangju, South Korea
[3] Chonnam Natl Univ, Adv Med Device Res Ctr Cardiovasc Dis, Gwangju, South Korea
来源
2023 IEEE 36TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, MEMS | 2023年
基金
新加坡国家研究基金会;
关键词
Polymer stent; wireless sensor; LC type pressure sensor; DRUG-ELUTING STENT; THROMBOSIS;
D O I
10.1109/MEMS49605.2023.10052470
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Cardiovascular disease (CVD) is the leading cause of death in worldwide. One of the main diseases is atherosclerosis, in which plaques build up in the walls of the arteries, causing them to narrow gradually. This narrowing effect of the arteries blocks blood flow and interrupts oxygen supply. One of the most common treatments utilized in the narrowed vessel is the insertion of a stent into the blood vessel. However, despite various stents decreasing the risk of recurrence, in-stent restenosis keeps the possibility of late thrombosis and subsequent heart attack. Therefore, to reveal restenosis at an early stage, non-invasive and accessible methods are required. The proposed new fabrication method for integrating wireless pressure sensor and foldable polymer stent is based on MEMS processes. Photosensitive polymer SU-8 was utilized as a body of mesh stent structure and LC wireless pressure sensor. Wireless pressure sensor connection and working principle was evaluated based on inductance and capacitance coupling circuit.
引用
收藏
页码:61 / 64
页数:4
相关论文
共 50 条
  • [31] Live Demonstration:Wireless Intracranial Pressure Monitoring System Based on an Air Pressure Sensor
    Wu, Zeliang
    Jiang, Hanjun
    Guo, Yanshu
    Zhang, Chun
    Jia, Wen
    Wang, Zhihua
    2017 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2017,
  • [32] A WIRELESS SENSOR NETWORK FOR ENDOTRACHEAL TUBE CUFF PRESSURE MONITORING
    Cipolletti, M.
    Martin Pirchio, F. N.
    Sanudo, S.
    Julian, P.
    Villalba, W.
    Masson, F.
    Mandolesi, P. S.
    LATIN AMERICAN APPLIED RESEARCH, 2009, 39 (01) : 27 - 32
  • [33] Flexible LC Sensor Array for Wireless Multizone Pressure Monitoring
    Zhang, Yunfan
    Tang, Wuyang
    Chen, Hongbin
    Li, Hui
    Xue, Zifan
    Shen, Shengnan
    IEEE SENSORS JOURNAL, 2024, 24 (03) : 2628 - 2636
  • [34] A wireless sensor network system for pressure and temperature signals monitoring
    Arshak, Khalil
    Jafer, Essa
    2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, : 1496 - 1501
  • [35] Evaluation of an Implantable Passive Sensor for Wireless Intracranial Pressure Monitoring
    Behfar, Mohammad
    Moradi, Elham
    Bjorninen, Toni
    Sydanheimo, Lauri
    Ukkonen, Leena
    2015 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2015, : 1201 - 1202
  • [36] Magnetic sensor for arterial distension and blood pressure monitoring
    Ruhhammer, Johannes
    Herbstritt, Tamara
    Ruh, Dominic
    Foerster, Katharina
    Heilmann, Claudia
    Beyersdorf, Friedhelm
    Goldschmidtboeing, Frank
    Seifert, Andreas
    Woias, Peter
    BIOMEDICAL MICRODEVICES, 2014, 16 (06) : 815 - 827
  • [37] Subcutaneous blood pressure monitoring with an implantable optical sensor
    Michael Theodor
    Dominic Ruh
    Jens Fiala
    Katharina Förster
    Claudia Heilmann
    Yiannos Manoli
    Friedhelm Beyersdorf
    Hans Zappe
    Andreas Seifert
    Biomedical Microdevices, 2013, 15 : 811 - 820
  • [38] Magnetic sensor for arterial distension and blood pressure monitoring
    Johannes Ruhhammer
    Tamara Herbstritt
    Dominic Ruh
    Katharina Foerster
    Claudia Heilmann
    Friedhelm Beyersdorf
    Frank Goldschmidtboeing
    Andreas Seifert
    Peter Woias
    Biomedical Microdevices, 2014, 16 : 815 - 827
  • [39] Subcutaneous blood pressure monitoring with an implantable optical sensor
    Theodor, Michael
    Ruh, Dominic
    Fiala, Jens
    Foerster, Katharina
    Heilmann, Claudia
    Manoli, Yiannos
    Beyersdorf, Friedhelm
    Zappe, Hans
    Seifert, Andreas
    BIOMEDICAL MICRODEVICES, 2013, 15 (05) : 811 - 820
  • [40] Blood pressure monitoring with piezoelectric bed sensor systems
    Xing, Xiaoman
    Li, Huan
    Chen, Qi
    Jiang, Chenyu
    Dong, Wen-fei
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 87