Impact of Glass Irradiation on Laser-Induced Breakdown Spectroscopy Data Analysis

被引:5
|
作者
Garrett, Londrea J. J. [1 ]
Morgan, Bryan W. W. [1 ]
Burger, Milos [1 ,2 ]
Lee, Yunu [3 ]
Kim, Hyeongbin [4 ]
Sabharwall, Piyush [5 ]
Choi, Sungyeol [4 ]
Jovanovic, Igor [1 ,2 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Gerard Mourou Ctr Ultrafast Opt Sci, Ann Arbor, MI 48109 USA
[3] Korea Adv Inst Sci & Technol, Dept Nucl & Quantum Engn, Daejeon 34141, South Korea
[4] Seoul Natl Univ, Dept Nucl Engn, Seoul 08826, South Korea
[5] Idaho Natl Lab, Idaho Falls, ID 83415 USA
关键词
laser-induced breakdown spectroscopy (LIBS); gamma irradiation; neutron irradiation; advanced reactors; optical absorption; EXPERIMENTAL STARK WIDTHS; SPECTRAL-LINES; INDUCED PLASMAS; LIBS; SHIFTS; ATOMS;
D O I
10.3390/s23020691
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Increased absorption of optical materials arising from exposure to ionizing radiation must be accounted for to accurately analyze laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on two examples that mimic the diagnostics placed within novel nuclear reactor designs. The analysis is performed on LIBS data measured with 1% Xe gas in an ambient He environment and 1% Eu in a molten LiCl-KCl matrix, along with the measured optical absorption from the gamma-and neutron-irradiated low OH fused silica and sapphire glasses. Significant changes in the number of laser shots required to reach a 3 sigma detection level are observed for the Eu data, increasing by two orders of magnitude after exposure to a 1.7 x 10(17) n/cm(2) neutron fluence. For all cases examined, the spectral dependence of absorption results in the introduction of systematic errors. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation leads to statistically significant changes in the temperatures calculated from the Xe II lines and Eu II lines, lowering them from 8000 +/- 610 K to 6900 +/- 810 K and from 15,800 +/- 400 K to 7200 +/- 800 K, respectively, for exposure to the 1.7 x 10(17) n/cm(2) fluence. The temperature range required for a 95% confidence interval for the calculated temperature is also broadened. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation attenuation is relatively small, or through analysis using the iterative Saha-Boltzmann method.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Forensic comparative glass analysis by laser-induced breakdown spectroscopy
    Bridge, Candice M.
    Powell, Joseph
    Steele, Katie L.
    Sigman, Michael E.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (12) : 1419 - 1425
  • [2] Quantitative Analysis on the Main Elements in Glass with Laser-Induced Breakdown Spectroscopy
    Dai Gege
    Chen Huacai
    2017 9TH INTERNATIONAL CONFERENCE ON ADVANCED INFOCOMM TECHNOLOGY (ICAIT 2017), 2017, : 10 - 14
  • [3] Discrimination of automotive glass by conjoint Raman and laser-induced breakdown spectroscopy and multivariate data analysis*
    Merk, Virginia
    Huber, Dominik
    Pfeifer, Lutz
    Damaske, Saskia
    Merk, Sven
    Werncke, Wolfgang
    Schuster, Michael
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 180
  • [4] Laser-induced breakdown spectroscopy with laser irradiation resonant with vibrational transitions
    Khachatrian, Ani
    Dagdigian, Paul J.
    APPLIED OPTICS, 2010, 49 (13) : C1 - C7
  • [5] Qualitative Analysis of Glass Microfragments Using the Combination of Laser-Induced Breakdown Spectroscopy and Refractive Index Data
    Palasti, David Jeno
    Kopniczky, Judit
    Voros, Tamas
    Metzinger, Aniko
    Galbacs, Gabor
    SENSORS, 2022, 22 (08)
  • [6] Double-pulse laser-induced breakdown spectroscopy for analysis of molten glass
    A.-M. Matiaske
    I. B. Gornushkin
    U. Panne
    Analytical and Bioanalytical Chemistry, 2012, 402 : 2597 - 2606
  • [7] Double-pulse laser-induced breakdown spectroscopy for analysis of molten glass
    Matiaske, A. -M.
    Gornushkin, I. B.
    Panne, U.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (08) : 2597 - 2606
  • [8] Critical aspects of data analysis for quantification in laser-induced breakdown spectroscopy
    Motto-Ros, V.
    Syvilay, D.
    Bassel, L.
    Negre, E.
    Trichard, F.
    Pelascini, F.
    El Haddad, J.
    Harhira, A.
    Moncayo, S.
    Picard, J.
    Devismes, D.
    Bousquet, B.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 140 : 54 - 64
  • [9] Laser-induced breakdown spectroscopy analysis of asbestos
    Caneve, L
    Colao, F
    Fabbri, F
    Fantoni, R
    Spizzichino, V
    Striber, J
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (7-8) : 1115 - 1120
  • [10] Slag analysis by laser-induced breakdown spectroscopy
    Doujak, G
    Mertens, R
    Ramb, W
    Flock, J
    Geyer, J
    Lüngen, S
    STAHL UND EISEN, 2001, 121 (03): : 53 - 58