Tower impulse grounding resistance measurement based on multiple frequency impedance

被引:3
|
作者
Dan, Yihua [1 ]
Zhang, Ruixuan [2 ]
Wu, Yongye [3 ]
Li, Yiqiao [4 ]
Wang, Xuement [5 ]
Yang, Jian [1 ,6 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing, Peoples R China
[2] State Grid Chongqing Elect Power Co, Inst Econ & Technol, Chongqing, Peoples R China
[3] Chengdu Power Supply Co, State Grid Sichuan Elect Power Co, Chengdu, Sichuan Provinc, Peoples R China
[4] State Grid Shaanxi Elect Power Co Ltd, Xian, Peoples R China
[5] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Sec, Chongqing, Peoples R China
[6] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
基金
中国博士后科学基金;
关键词
impulse grounding resistance; lightning protection; measurement methods; multiple frequency impedance; LARGE-SCALE TESTS; ELECTRODES;
D O I
10.1049/gtd2.12876
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Tower impulse grounding resistance is important for judging the lightning protection performance of transmission lines. Therefore, it is significant to accurately measure the tower impulse grounding resistance. Existing measurement methods mainly contain the real-type test method and the impulse coefficient method. However, the real-type test method requires heavy and complex excitation and measuring equipment, which is difficult to be used in a practical environment. The impulse coefficient method adopts the empirical equations, which could have large measurement errors in different environments. To solve the above problems, this paper studies a novel impulse grounding resistance measurement method (IGRMM) based on multiple frequency impedance. Spectrum characteristics of typical lightning currents and the calculation method of impulse grounding resistance of grounding electrodes are studied, the IGRMM is proposed. Finally, a case study and on-site tests are carried out. The results show that the proposed IGRMM can accurately obtain the impulse grounding resistance by measuring grounding impedance at a few frequency points, which helps accurate and convenient evaluation of impulse grounding performance in practical environments and lightning protection performance of the power transmission systems.
引用
收藏
页码:3488 / 3500
页数:13
相关论文
共 50 条
  • [41] Measurement of grounding system resistance based on ground high frequency behavior for different soil type
    Jambak, MI
    Ahmad, H
    IEEE 2000 TENCON PROCEEDINGS, VOLS I-III: INTELLIGENT SYSTEMS AND TECHNOLOGIES FOR THE NEW MILLENNIUM, 2000, : B207 - B211
  • [42] A new impulse grounding resistance measuring instrument
    Dai Wenjin
    Wang Kai
    APPLIED MECHANICS AND MECHANICAL ENGINEERING, PTS 1-3, 2010, 29-32 : 991 - 996
  • [43] Some Notes on the Impulse Characteristics of Type A Grounding of Transmission Line Tower
    Bajramovic, Z.
    Mujezinovic, A.
    Turkovic, I.
    Avdakovic, S.
    Carsimamovic, S.
    Veledar, M.
    2017 2ND INTERNATIONAL MULTIDISCIPLINARY CONFERENCE ON COMPUTER AND ENERGY SCIENCE (SPLITECH), 2017, : 255 - 260
  • [44] Wavelet-based Analysis of Impulse Grounding Resistance-Experimental Study of the "A"-type Grounding System
    Veledar, Meludin
    Avdakovic, Samir
    Bajramovic, Zijad
    Savic, Milan
    Stankovic, Koviljka
    Carsimamovic, Adnan
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2015, 43 (19) : 2189 - 2195
  • [45] Calculation of the impulse impedance of a long grounding rod in sandy soil
    Annenkov, VZ
    ELECTRICAL TECHNOLOGY RUSSIA, 1998, (02): : 38 - 45
  • [46] Research on Field Test of Impulse Grounding Impedance for Small Substation
    Si Wen-Rong
    Fu Chen-Zhao
    Chen Lu
    Lu Qi-Yu
    Bao Hai-Long
    Yuan Peng
    2018 INTERNATIONAL CONFERENCE ON SMART GRID AND ELECTRICAL AUTOMATION (ICSGEA), 2018, : 159 - 162
  • [47] Fault Diagnosis of Tower Grounding Conductor Based on the Electromagnetic Measurement and Neural Network
    Lu, Caijiang
    Zhang, Tianyi
    Sun, Shaoheng
    Cao, Zhongqing
    Xin, Mingyong
    Fu, Guoqiang
    Wang, Tao
    Wang, Xi
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [48] EFFECT OF SOIL IONIZATION ON IMPULSE IMPEDANCE OF GROUNDING ELECTRODES.
    Gupta, B.R.
    Thapar, B.
    Journal of the Institution of Engineers (India): Electrical Engineering Division, 1983, 64 : 51 - 55
  • [49] Frequency-dependent grounding impedance of the counterpoise based on the dispersed currents
    Choi, Jong-Hyuk
    Lee, Bok-Hee
    Paek, Seung-Kwon
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2012, 7 (04) : 589 - 595
  • [50] Study on Resistance Reduction Efficiency of Grounding Module in Transmission Tower Grounding Grid
    Zhao, Wenlong
    Hu, Yuanchao
    Chen, Jiajia
    Jing, Dong
    Gao, Xiaojing
    Jiang, Zhipeng
    2019 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT GREEN BUILDING AND SMART GRID (IGBSG 2019), 2019, : 103 - 107