All fiber optic current sensor based on phase-shift fiber loop ringdown structure

被引:10
|
作者
Yu, Aodi [1 ]
Huang, Yuhao [1 ,2 ]
Li, Shiyu [1 ]
Wang, Zhuoying [1 ]
Xia, Li [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Opt & Elect Informat, Wuhan 430074, Peoples R China
[2] Univ Hong Kong, Dept Elect & Elect Engn, Hong Kong 999077, Peoples R China
关键词
SENSITIVITY; TEMPERATURE; ERROR;
D O I
10.1364/OL.489190
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An all fiber optic current sensor (AFOCS) utilizing ordinary optical fiber is proposed and demonstrated, which is imple-mented with a phase-shift fiber loop ringdown (PS-FLRD) structure. The current-induced rotation angle is converted into a minute change in transmittance of the fiber loop, which can be obtained by measuring the phase shift. The current sensitivity is improved by allowing optical signals to traverse the sensing fiber repeatedly. The relationship between the current sensitivity, intrinsic phase shift, and initial trans-mittance of the fiber loop is numerically analyzed, and the tunable sensitivity is experimentally verified by adjusting the modulation frequency. An optimal current sensitivity of 0.8158 degrees/A is experimentally obtained for the proposed sen-sor, and the minimum detectable current is at least 100 mA. The proposed sensor requires fewer polarization elements compared with the common type of fiber optic current sen-sor (FOCS) and has the characteristics of simple structure, high sensitivity, and ease of operation; it will be a promising approach in practical applications. (c) 2023 Optica Publishing Group
引用
收藏
页码:2925 / 2928
页数:4
相关论文
共 50 条
  • [41] Fiber optic current sensor calibration
    Blake, J
    2001 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION, VOLS 1 AND 2: DEVELOPING NEW PERSPECTIVES, 2001, : 127 - 130
  • [42] Highly sensitive fiber loop ringdown strain sensor using photonic crystal fiber interferometer
    Zhou, Wenjun
    Wong, Wei Chang
    Chan, Chi Chiu
    Shao, Li-Yang
    Dong, Xinyong
    APPLIED OPTICS, 2011, 50 (19) : 3087 - 3092
  • [43] Fiber Fabry-Perot cavity using Sagnac loop with phase-shift grating
    Li, H
    Huang, DX
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2001, 22 (10): : 1511 - 1519
  • [44] Fiber Fabry-Perot Cavity Using Sagnac Loop with Phase-Shift Grating
    Li Hong
    Huang Dexiu
    International Journal of Infrared and Millimeter Waves, 2001, 22 : 1511 - 1519
  • [45] Thermal-induced phase-shift error of a fiber-optic gyroscope due to fiber tail length asymmetry
    Zhang, Yunhao
    Zhang, Yonggang
    Gao, Zhongxing
    APPLIED OPTICS, 2017, 56 (02) : 273 - 277
  • [46] Optical coherence tomography application by using optical phase shift based on fiber optic sensor
    Lee, Seung Seok
    Kim, Joo Ha
    Eom, Tae Joong
    Choi, Eun Seo
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XVI, 2016, 9702
  • [47] Research on the compensating fiber loop for eliminating vibration in Sagnac optic current sensor
    Li, Xuyou
    Hao, Jinhui
    Yang, Hanrui
    Yang, Junwei
    Chen, Liang
    He, Zhou
    Zhongguo Jiguang/Chinese Journal of Lasers, 2012, 39 (02):
  • [48] Hybrid Structure Multichannel All-Fiber Current Sensor
    Jiang, Junzhen
    Zhang, Hao
    He, Youwu
    Qiu, Yishen
    SENSORS, 2017, 17 (08)
  • [49] All-Fiber Optic Temperature Sensor
    蒋雁
    庞叔鸣
    杨祥林
    Journal of Southeast University(English Edition), 1997, (02) : 50 - 54
  • [50] PRACTICAL SAGNAC INTERFEROMETER BASED FIBER OPTIC CURRENT SENSOR
    YU, A
    SIDDIQUI, AS
    IEE PROCEEDINGS-OPTOELECTRONICS, 1994, 141 (04): : 249 - 256