Impact of intensive follow-up of cardiac implantable electronic devices via remote monitoring: A pilot study

被引:2
|
作者
Heath, Kyle [1 ]
O'Shea, Catherine [1 ,2 ]
Thomas, Gijo [1 ]
Harper, Curtis [3 ]
Campbell, Kevin [4 ]
Sanders, Prashanthan [1 ,2 ]
Middeldorp, Melissa E. [1 ,5 ,6 ]
机构
[1] Univ Adelaide, Ctr Heart Rhythm Disorders CHRD, Adelaide, SA, Australia
[2] Royal Adelaide Hosptial, Adelaide, SA, Australia
[3] PaceMate, Bradenton, FL USA
[4] Hlth First Heart & Vasc, Cocoa Beach, FL USA
[5] Cedar Sinai Smidt Heart Inst, Los Angeles, CA USA
[6] Univ Adelaide, Ctr Heart Rhythm Disorders, C Cardiol Unit, 1 Port Rd, Adelaide, SA 5000, Australia
来源
HEART RHYTHM O2 | 2023年 / 4卷 / 02期
关键词
Remote; Workflow; CIED; Intensive; Burden; Streamline; HEART-FAILURE PATIENTS; TIME; CARE; DEFIBRILLATORS; EFFICACY; WORKFLOW; EVENTS; SAFETY;
D O I
10.1016/j.hroo.2022.11.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The volume of remote monitoring (RM) data gener-ates a significant workload and is generally dealt with by clinic staff during standard office hours, potentially delaying clinical action.OBJECTIVE The purpose of this study was to determine the clinical efficiency and workflow of implementing intensive RM (IRM) in pa-tients with cardiac implantable electronic device (CIED) when compared with standard RM (SRM).METHODS From a cohort of .1500 remotely monitored devices, 70 patients were randomly selected to undergo IRM. For comparison, an equal number of matched patients were prospectively selected for SRM. Intensive follow-up occurred via automated vendor-neutral software with rapid alert processing by International Board of Heart Rhythm Examiners-certified device specialists. Standard follow-up was conducted by clinic staff during office hours via indi-vidual device vendor interfaces. Alerts were categorized on the basis of the level of acuity as actionable (red [high], yellow [moderate]), or green [not requiring action]).RESULTS Over 9 months of follow-up, 922 remote transmissions were received; 339 (36.8%) were coded as actionable alerts (118 in IRM and 221 in SRM; P < .001). The median time from initial transmission to review was 6 hours (interquartile range [IQR] 1.8-16.8 hours) in the IRM group compared with 10.5 hours (IQR 6.0-32.2 hours) in the SRM group (P < .001). The median time from transmission to review of actionable alerts in the IRM group was 5.1 hours (IQR 2.3-8.9 hours) compared with 9.1 hours (IQR 6.7-32.5 hours) in the SRM group (P < .001).CONCLUSION Intensive and managed RM results in a significant reduction in time to review alerts and number of actionable alerts. Monitoring with enhanced alert adjudication is needed to facilitate device clinic efficiency and optimize patient care.STUDY REGISTRATION ACTRN12621001275853
引用
收藏
页码:90 / 96
页数:7
相关论文
共 50 条
  • [21] Remote Monitoring of Cardiac Implantable Electronic Devices: What is the Evidence?
    Reinhardt, Adrian
    Ventura, Rodolfo
    CURRENT HEART FAILURE REPORTS, 2023, 20 (01) : 12 - 23
  • [22] Remote Monitoring of Cardiac Implantable Electronic Devices: What is the Evidence?
    Adrian Reinhardt
    Rodolfo Ventura
    Current Heart Failure Reports, 2023, 20 : 12 - 23
  • [23] Remote monitoring for cardiac implantable electronic devices: A practical guide
    Klein, Cedric
    Finat, Loic
    Abbey, Selim
    Eschalier, Romain
    Fossati, Frederic
    Lazarus, Arnaud
    Marijon, Eloi
    Pasquie, Jean-Luc
    Ploux, Sylvain
    Salerno, Fiorella
    Williatte, Lina
    Gras, Daniel
    Sacher, Frederic
    Taieb, Jerome
    Boveda, Serge
    Guedon-Moreau, Laurence
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2022, 115 (6-7) : 406 - 407
  • [24] Paramedics and remote monitoring of cardiac implantable electronic devices in France
    Mette, Carole
    Prost, Diane
    Baud, Julien
    Taieb, Jerome
    Marijon, Eloi
    Piot, Olivier
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2024, 117 (02) : 117 - 118
  • [25] Remote monitoring of cardiac implantable electronic devices and disease management
    Varma, Niraj
    Braunschweig, Frieder
    Burri, Haran
    Hindricks, Gerhard
    Linz, Dominik
    Michowitz, Yoav
    Ricci, Renato Pietro
    Nielsen, Jens Cosedis
    EUROPACE, 2023, 25 (09):
  • [26] REMOTE MONITORING OF THE CARDIAC IMPLANTABLE ELECTRONIC DEVICES AT THE CIRIE' HOSPITAL
    Condo, C.
    Ban, E. Macario
    Astegiano, V.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (0C) : C116 - C116
  • [27] Challenges in the remote monitoring of cardiac implantable electronic devices in 2021
    Malanchini, Giovanni
    Ferrari, Gabriele
    Leidi, Cristina
    Ferrari, Paola
    Senni, Michele
    De Filippo, Paolo
    KARDIOLOGIA POLSKA, 2021, 79 (04) : 380 - 385
  • [28] Switching to a 100% remote follow-up of implantable cardiac electronic devices: Organizational model and results of a single center experience
    Miracapillo, Gennaro
    Addonisio, Luigi
    De Sensi, Francesco
    Orselli, Paolo
    Piccinetti, Elena
    Aramini, Carla
    Limbruno, Ugo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (08) : 1548 - 1558
  • [29] Scheduled versus alert transmissions for remote follow-up of cardiac implantable electronic devices: Clinical relevance and resource consumption
    Maines, Massimiliano
    Tomasi, Giancarlo
    Moggio, Paolo
    Poian, Luisa
    Peruzza, Francesco
    Catanzariti, Domenico
    Angheben, Carlo
    Cont, Natascia
    Valsecchi, Sergio
    Del Greco, Maurizio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 334 : 49 - 54
  • [30] Remote monitoring and follow-up of cardiovascular implantable electronic devices in the Netherlands An expert consensus report of the Netherlands Society of Cardiology
    de Cock, C. C.
    Elders, J.
    van Hemel, N. M.
    van den Broek, K.
    van Erven, L.
    de Mol, B.
    Talmon, J.
    Theuns, D. A. M. J.
    de Voogt, W.
    NETHERLANDS HEART JOURNAL, 2012, 20 (02) : 53 - 65