Hemodynamic predictors of negative false lumen remodeling after frozen elephant trunk for acute aortic dissection

被引:0
|
作者
Takei, Yusuke [1 ]
Miyazaki, Shohei [2 ]
Suzuki, Kohei [2 ]
Saito, Shunsuke [2 ]
Oogaki, Hayato [3 ]
Muraoka, Yuki [3 ]
Ogasawara, Takeshi [4 ]
Tezuka, Masahiro [1 ]
Shibasaki, Ikuko [1 ]
Fukuda, Hirotsugu [1 ]
机构
[1] Dokkyo Med Univ, Dept Cardiac & Vasc Surg, Grad Sch Med, 880 Kitakobayashi, Mibu, Tochigi 3210293, Japan
[2] Cardio Flow Design Inc, Tokyo, Tokyo, Japan
[3] Dokkyo Med Univ, Koshigaya Hosp, Dept Radiol, Mibu, Tochigi, Japan
[4] Dokkyo Med Univ, Dept Fundamental Educ, Math & Stat Sect, 880 Kitakobayashi,Mibu Machi, Simotuga Gun, Tochigi 3210293, Japan
关键词
Frozen elephant trunk; Four-dimensional flow magnetic resonance imaging; Negative false lumen remodeling; TOTAL ARCH REPLACEMENT; STENT GRAFT; REPAIR; DISTAL; OUTCOMES; ENTRY;
D O I
10.1007/s11748-023-01984-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective We evaluated the blood flow within the downstream aortic false lumen after frozen elephant trunk repair for acute aortic dissection and identified hemodynamic predictors of false lumen expansion and negative false lumen remodeling using four-dimensional flow magnetic resonance imaging.Methods Thirty-one patients (Stanford type A, n = 28; Stanford type B, n = 3) with patent false lumen who underwent frozen elephant trunk procedures for acute aortic dissection were included in this observational study. Each patient underwent computed tomography during the follow-up period and four-dimensional flow magnetic resonance imaging within 3 postoperative months. The false lumen volumetric expansion rate was calculated using computed tomography data. The direction and the rate of flow in the lower descending aortic false lumen were analyzed. Negative false lumen remodeling was defined as a volumetric increase of > 10% from the baseline volume.Results Negative false lumen remodeling had developed in 6 of the 31 patients during the observation period. Most of the false lumen flows were biphasic during systole. The range between peak and nadir flow rates was associated with the false lumen volumetric expansion rate (beta coefficient = 6.77; p < 0.01, R-2 = 0.43).Conclusions The range between peak and nadir flow rates may serve as a hemodynamic predictor of negative false lumen remodeling, enabling further treatment for patients at risk of expansion in the downstream aorta.
引用
收藏
页码:376 / 386
页数:11
相关论文
共 50 条
  • [21] Efficacy of Frozen Elephant Trunk for Acute Type A Aortic Dissection
    Tsumaru, Shinichi
    Shimamoto, Takeshi
    CIRCULATION, 2023, 148
  • [22] Tetraplegia after branched frozen elephant trunk implantation for acute type A aortic dissection
    Ranchordas, Sara
    du Puy-Montbrun, Leonora
    Bel, Alain
    Achouh, Paul
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (07) : 1694 - 1696
  • [23] Rapid false lumen dilation and pseudocoarctation due to inadvertent preferential false lumen perfusion using the frozen elephant trunk technique in a chronic residual aortic dissection
    Fleerakkers, Jelle
    Sonker, Uday
    Heijmen, Robin H.
    JOURNAL OF VASCULAR SURGERY CASES AND INNOVATIVE TECHNIQUES, 2020, 6 (01): : 101 - 103
  • [24] Frozen elephant trunk surgery in aortic dissection
    Celmeta, Bleri
    Harky, Amer
    Miceli, Antonio
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [25] Frozen elephant trunk the way to go in acute aortic dissection in 2020
    Idhrees, Mohammed
    Hosseini, Saeid
    Rezaei, Yousef
    Mousavizadeh, Mostafa
    Daliri, Mahdi
    Aljadayel, Hadi Abo
    Bashir, Mohamad
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (08) : 3011 - 3012
  • [26] Frozen Elephant Trunk Technique in Acute Type A Aortic Dissection: Is It for All?
    Chivasso, Pierpaolo
    Mastrogiovanni, Generoso
    Miele, Mario
    Bruno, Vito Domenico
    Rosciano, Antonio
    Montella, Antonio Pio
    Triggiani, Donato
    Colombino, Mario
    Cafarelli, Francesco
    Leone, Rocco
    Masiello, Paolo
    Iesu, Severino
    MEDICINA-LITHUANIA, 2021, 57 (09):
  • [27] Rescue of False Lumen Frozen Elephant Trunk Deployment Intraoperatively
    Witcher, Adam C.
    Meers, Brad
    Lewis, Clifton T.
    Beck, Adam W.
    Eudailey, Kyle W.
    ANNALS OF THORACIC SURGERY, 2023, 116 (02): : E5 - E7
  • [28] Endovascular rescue for malpositioned frozen elephant trunk into the false lumen
    Takagi, Daichi
    Wada, Takuya
    Igarashi, Wataru
    Kadohama, Takayuki
    Kiryu, Kentaro
    Arai, Takeshi
    Yamamoto, Hiroshi
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (10) : 3948 - 3951
  • [29] The frozen elephant trunk technique for retrograde acute type A aortic dissection
    Tamura, Kentaro
    Uchida, Naomichi
    Katayama, Akira
    Sutoh, Miwa
    Kuraoka, Masatsugu
    Sueda, Taijiro
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (02): : 561 - 565
  • [30] The fenestrated frozen elephant trunk technique for acute type A aortic dissection
    Okamura, Homare
    Arakawa, Mamoru
    Takeuchi, Taro
    Adachi, Hideo
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 156 (02): : E75 - E77