Discrimination of piled-up neutron-gamma pulses using charge comparison method and neural network for CLYC detectors

被引:1
|
作者
Yi, Chuqi [1 ]
Han, Jifeng [1 ]
Song, Ruiqiang [1 ]
Yan, Xiaoyu [1 ]
Ren, Feixu [1 ]
Luo, Xiaobing [1 ]
Han, Zheng [1 ]
Wen, Chun [1 ]
Qu, Guofeng [1 ,4 ]
Liu, Xingquan [1 ]
Lin, Weiping [1 ]
Wang, Peng [1 ]
Fan, Yixiang [1 ]
Qian, Sen [2 ]
Wang, Zhigang [2 ]
Tang, Gao [3 ]
Qin, Laishun [3 ]
Wang, Xu [5 ]
Liu, Jizhen [5 ]
机构
[1] Sichuan Univ, Inst Nucl Sci & Technol, Key Lab Radiat Phys & Technol, Minist Educ, Chengdu 610064, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[3] China Jiliang Univ, Coll Mat & Chem, Hangzhou 310018, Peoples R China
[4] Johannes Gutenberg Univ Mainz, Helmholtz Inst, D-55099 Mainz, Germany
[5] Nucl Power Inst China, Chengdu 610005, Peoples R China
关键词
Cs2LiYCl6: Ce3+scintillator; Pulse shape discrimination; Charge comparison method; Neural network; SHAPE DISCRIMINATION; SCINTILLATION; RAYS;
D O I
10.1016/j.nima.2023.168561
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To realize neutron-gamma discrimination of piled-up pulses in high counting rate circumstances, the discrim-ination performance of the charge comparison method and three neural network models to actual piled-up pulses was studied in this paper. The neural network models, including a residual neural network (ResNet), a convolutional neural network (CNN) and a fully connected neural network (FCNN), were trained and tested by seven kinds of actual experimental data sets, which included the background signals (bg), non-piled-up neutron (n) and gamma (g) pulses as well as piled-up neutron + neutron (n + n), neutron + gamma (n + g), gamma + neutron (g + n), and gamma + gamma (g + g) pulses. The labels of the seven data sets were provided after discriminating by the charge comparison method. The results showed that the charge comparison method could be applied to discriminate piled-up neutron-gamma pulses with the Figure of Merit (FoM) value of 1.0. The integration length has been optimized to be different for piled-up and non-piled-up pulses, but follow the same criterion for neutron and gamma discrimination. The FoM values are worse than that of non-piled-up signals because the baseline fluctuation is very large under high counting rate conditions, which gives lots of interference to pulse shape discrimination. The ResNet model has the highest total prediction accuracy (93.85%) for the seven signal types, and through the comparison and analysis of the inconsistent events discriminated by the charge comparison method and the ResNet model, it is concluded that the discrimination result of the ResNet model is more accurate. These results indicate that both the charge comparison method and residual neural network can be used for complicated n/? discrimination under high counting rate conditions, and the residual neural network works better.
引用
收藏
页数:8
相关论文
共 28 条
  • [21] NEUTRON-GAMMA PULSE SHAPE DISCRIMINATION WITH A NE-213 LIQUID SCINTILLATOR BY USING DIGITAL SIGNAL PROCESSING COMBINED WITH SIMILARITY METHOD
    Mardiyanto
    ATOM INDONESIA, 2008, 34 (02) : 103 - 115
  • [22] A bulk analysis system using the prompt gamma neutron activation method and neural network
    Ali Taheri
    Saeed Heidary
    Reza Gholipour Peyvandi
    The European Physical Journal Plus, 132
  • [23] A bulk analysis system using the prompt gamma neutron activation method and neural network
    Taheri, Ali
    Heidary, Saeed
    Peyvandi, Reza Gholipour
    EUROPEAN PHYSICAL JOURNAL PLUS, 2017, 132 (06):
  • [24] Up Down Gamma Discrimination using the Imaging Ratio Method with CZT Gamma-Ray Detectors for In Situ and Remote Sensing Operations
    Nowicki, Suzanne F.
    Hunter, Stanley D.
    Parsons, Ann. M.
    Chen, Henry
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [25] Simultaneous alpha and gamma discrimination with a phoswich detector using a rise time method and an artificial neural network method
    Panahi, R.
    Feghhi, S. A. H.
    Moghadam, S. Rajabi
    Zamzamian, S. M.
    APPLIED RADIATION AND ISOTOPES, 2019, 154
  • [26] Multilayer Perceptron Model Versus Charge Comparison Method for Neutron/Gamma Discrimination in Plastic Scintillator According to Sampling Frequency and Energy Radiation
    Hachem, A.
    Moline, Y.
    Corre, G.
    Gauthier, J.
    Carrel, F.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2023, 70 (09) : 2212 - 2217
  • [27] Real-Time Implementation of the Neutron/Gamma Discrimination in an FPGA-Based DAQ MTCA Platform Using a Convolutional Neural Network
    Astrain, Miguel
    Ruiz, Mariano
    Stephen, Adam, V
    Sarwar, Rashed
    Carpeno, Antonio
    Esquembri, Sergio
    Murari, Andrea
    Belli, Francesco
    Riva, Marco
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2021, 68 (08) : 2173 - 2178
  • [28] Multilayer Perception Model Versus Charge Comparison Method for Neutron/Gamma Discrimination in Plastic Scintillator According to Sampling Frequency and Energy Radiation (vol 70, pg 2212, 2023)
    Hachem, A.
    Moline, Y.
    Corre, G.
    Gauthier, J.
    Carrel, F.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2024, 71 (01) : 121 - 123