Dose indices of kilovoltage cone beam computed tomography for various image guided radiotherapy protocols

被引:2
|
作者
Gazdag-Hegyesi, Szilvia [1 ,3 ]
Galdi, Adam [1 ,2 ]
Major, Tibor [1 ,2 ]
Pesznyak, Csilla [1 ,3 ]
机构
[1] Natl Inst Oncol, Ctr Radiotherapy, Budapest, Hungary
[2] Semmelweis Univ, Dept Oncol, Budapest, Hungary
[3] Budapest Univ Technol & Econ, Inst Nucl Tech, Budapest, Hungary
关键词
QUALITY; CBCT; CT;
D O I
10.1093/rpd/ncad101
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Varian Halcyon (HA) linear accelerators (LINAC) require kilovoltage cone-beam computed tomography (CT) acquisition for all patients before all treatment fractions. The aim of this study is to compare dose indices of various available protocols with different calculation and measurement methods. CT dose index (CTDI) in mGy is a measure of the radiation dose output of a CT scanner. A pencil ionisation chamber was used to measure dose index free air and in a standard CTDI phantom for different imaging protocols of HA and TrueBeam LINACs. For the point measurements, we found large deviations between displayed and calculated low CTDI values: 26.6 and 27.1% at Head low dose and Breast protocol, respectively. The calculated values were always larger than the displayed ones for all protocols and measurement setups. For the point measurements similar results were found as in the international literature, where the displayed values the measured CTDIs.
引用
收藏
页码:983 / 988
页数:6
相关论文
共 50 条
  • [31] Radiation Dose and Image Quality in Various Examinations and Imaging Modes of Dentomaxillofacial Cone Beam Computed Tomography
    Toossi M.T.B.
    Zafari N.
    Hoseini-Zarch S.H.
    Dolat E.
    Azimian H.
    Moghadam M.S.
    Iranian Journal of Medical Physics, 2022, 19 (03) : 159 - 166
  • [32] Effect of diagnostic cone-beam computed tomography protocols on image quality, patient dose, and lesion detection
    Paul, Jijo
    Chacko, Annamma
    Saccomandi, Paola
    Vogl, Thomas J.
    Nour-Eldin, Nour-Eldin A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12): : 1575 - 1583
  • [33] Evaluation and choice of imaging protocols on the Elekta XVI® kilovoltage cone-beam computed tomography imaging system
    Werle, F.
    Buffard, E.
    Brune, K.
    Perrin, B.
    Atlani, D.
    CANCER RADIOTHERAPIE, 2014, 18 (01): : 47 - 54
  • [34] A novel evaluation model of image registration for cone-beam computed tomography guided lung cancer radiotherapy
    Liu, Yimei
    Chen, Meining
    Fang, Jianlan
    Xiao, Liangjie
    Liu, Songran
    Li, Qiwen
    Qiu, Bo
    Huang, Runda
    Zhang, Jun
    Peng, Yinglin
    THORACIC CANCER, 2024, 15 (17) : 1333 - 1342
  • [35] Dual-energy material decomposition for cone-beam computed tomography in image-guided radiotherapy
    Skaarup, Mikkel
    Edmund, Jens M.
    Dorn, Sabrina
    Kachelriess, Marc
    Vogeliu, Ivan R.
    ACTA ONCOLOGICA, 2019, 58 (10) : 1483 - 1488
  • [36] Imaging Dose From Kilovoltage Cone Beam Computed Tomography On a TrueBeam Linear Accelerator in Radiation Therapy
    Pan, X.
    Bradley, W.
    Ochran, T.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [37] INCORPORATION OF DAILY KILOVOLTAGE CONE-BEAM COMPUTED TOMOGRAPHY IMAGING DOSE INTO IMRT PLAN OPTIMIZATION
    Dogan, N.
    Vile, D.
    Zheng, D.
    Weiss, E.
    Lu, J.
    Williamson, J.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S436 - S437
  • [38] Patient-Specific Three-Dimensional Concomitant Dose From Cone Beam Computed Tomography Exposure in Image-Guided Radiotherapy
    Spezi, Emiliano
    Downes, Patrick
    Jarvis, Richard
    Radu, Emil
    Staffurth, John
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (01): : 419 - 426
  • [39] Imaging dose of cone-beam computed tomography in nanoparticle-enhanced image-guided radiotherapy: A Monte Carlo phantom study
    Mututantri-Bastiyange, Dewmini
    Chow, James C. L.
    AIMS BIOENGINEERING, 2020, 7 (01): : 1 - 11
  • [40] A Correction Algorithm for Kilovoltage Cone-Beam Computed Tomography Dose Calculations in Cervical Cancer Patients
    Zhang, J.
    Zhang, W.
    Lu, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3242 - 3242