Failure Analysis of Heat Exchanger Using Eddy Current Testing (ECT)

被引:4
|
作者
Saffiudeen, Mohamed Fayas [1 ]
Syed, Abdullah [1 ]
Mohammed, Fasil T. [1 ]
机构
[1] Royal Commiss Jubail & Yanbu, Jubail Tech Inst, Dept Mech Skills, Jubail Ind City, Saudi Arabia
关键词
Heat exchanger; Tube inspection; Eddy current testing; Retubing; Maintenance; CORROSION; TUBE; INSPECTION; PERFORMANCE; EROSION; NDE;
D O I
10.1007/s11668-023-01746-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Shell and tube heat exchangers are widely used in the oil and gas, petrochemical and nuclear power sectors. The most important aspect of the turnaround is the routine testing and inspection of the in-service heat exchanger. Heat exchangers in use are the primary cause of tube flaws such as pitting, corrosion, erosion, fretting corrosion, crevice corrosion, stress corrosion cracking, wear, galvanic corrosion, fatigue cracking, microbiologically influenced corrosion, and so forth. For research, a seamless nickel-iron-chromium alloy-tubed SB 163 (UNS 8810) heat exchanger was taken. The total number of tubes that need to be inspected is 286 tubes with a specification of 19.05 mm OD x 2.11 mm thickness x 5000 mm length. From the different advanced NDT techniques, the eddy current testing (ECT) was chosen for inspection since it has become one of the most popular NDT methods for locating discontinuities in heat exchanger tubes. A standard calibration tube was used to calibrate the system's response and set the sensitivity. During the inspection, the ECT probe was inserted from the below side up to the other end and collected while pulling the probe from the tube. Inspection data were recorded for the length of each tube. All indications were assessed, and defects were categorized as different extents of wall thickness loss after inspection. The inspection report shows how many tubes were found defective and need to be plugged or removed (retubing). From the inspection data (the result of statistics), defects like corrosion, pitting, wall loss, wear, etc., that resulted in notable material loss were identified. Inspection data also summarized where the defects were located (like between the first baffle and the second baffle) and are helpful for further research. After analysis using ECT reports, the defective tubes were categorized according to their defect percentage and location, which helps to do retubing effectively by avoiding the 100% retubing concept.
引用
下载
收藏
页码:1898 / 1906
页数:9
相关论文
共 50 条
  • [1] Failure Analysis of Heat Exchanger Using Eddy Current Testing (ECT)
    Mohamed Fayas Saffiudeen
    Abdullah Syed
    Fasil T. Mohammed
    Journal of Failure Analysis and Prevention, 2023, 23 : 1898 - 1906
  • [2] Comparative study of heat exchanger tubes failure analysis using ECT and IRIS
    Saffiudeen, Mohamed Fayas
    Syed, Abdullah
    Mohammed, Fasil T.
    Mughal, Mohammad Asghar
    Alamri, Yassir A.
    Alanazi, Mubarak A.
    Interactions, 2024, 245 (01)
  • [3] Detection of circumferential cracks in heat exchanger tubes using pulsed eddy current testing
    Yu, Zhaohu
    Fu, Yuewen
    Jiang, Lifan
    Yang, Fan
    NDT & E INTERNATIONAL, 2021, 121
  • [4] INSPECTION OF HEAT-EXCHANGER TUBING BY PHASE ANALYSIS EDDY-CURRENT TESTING
    DENTON, CJ
    MATERIALS EVALUATION, 1974, 32 (09) : A35 - A36
  • [5] A radiographic calibration method for eddy current testing of heat exchanger tubes
    Movafeghi, A
    Kargarnovin, MH
    Soltanianzadeh, H
    Edalati, K
    Rokrok, B
    Kermani, A
    Seidi, M
    INSIGHT, 2004, 46 (10) : 594 - 597
  • [6] Remote Field Eddy Current Testing Technology for Ferromagnetic Heat Exchanger Tubes
    Chen, Yubao
    Zheng, Jiong
    Luo, Weijian
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, PVP 2012, VOL 5: HIGH-PRESSURE TECHNOLOGY NONDESTRUCTIVE EVALUATION DIVISION, 2012, : 237 - 239
  • [7] THE SCIENCE BEHIND EDDY CURRENT AND REMOTE FIELD TESTING: FOR CONDENSER AND HEAT EXCHANGER TUBING
    Van Name, Christopher
    Fischer, Gary
    Kocher, James
    PROCEEDINGS OF THE ASME POWER CONFERENCE, 2016, 2016,
  • [8] QUANTITATIVE SYSTEM FOR EVALUATING EDDY-CURRENT TESTING OF HEAT-EXCHANGER TUBING
    SHINDO, Y
    YOSHIE, S
    MARIMOTO, M
    MATERIALS EVALUATION, 1985, 43 (10) : 1299 - 1299
  • [9] Classifiability Analysis of Indications by Eddy-Current Testing of Nuclear Power Plant Heat-Exchanger Tube
    Grman, Jan
    Syrova, Livia
    PROCEEDINGS OF 19TH INTERNATIONAL CONFERENCE RADIOELEKTRONIKA 2009, 2009, : 285 - 288
  • [10] In situ eddy current inspection of heat exchanger tubes
    Trivedi, AJ
    Parikh, RR
    TRENDS IN NDE SCIENCE AND TECHNOLOGY - PROCEEDINGS OF THE 14TH WORLD CONFERENCE ON NDT (14TH WCNDT), VOLS 1-5, 1996, : 1729 - 1735