Assessment of the ITER divertor bolometer diagnostic performance

被引:0
|
作者
Brank, M. [1 ]
Pitts, R. A. [2 ]
Kalvin, S. [3 ]
Zoletnik, S. [3 ]
Koechl, F. [4 ]
Meister, H. [5 ]
Neverov, V. S. [6 ]
Reichle, R. [2 ]
Schneider, M. [2 ]
Kos, L. [1 ]
机构
[1] Univ Ljubljana, Fac Mech Engn, Askerceva 6, Ljubljana 1000, Slovenia
[2] ITER Org, Route Vinon Sur Verdon,CS 90 046, F-13067 St Paul Les Durance, France
[3] Wigner Res Ctr Phys, H-1525 Budapest, Hungary
[4] Culham Sci Ctr, CCFE, Abingdon OX14 3DB, England
[5] Max Planck Inst Plasma Phys, Boltzmannstr 2, D-85748 Garching, Germany
[6] Kurchatov Inst, Natl Res Ctr, Moscow 123182, Russia
关键词
Bolometry; Tomographic reconstruction; OPTIMIZATION; COLLIMATORS; DESIGN;
D O I
10.1016/j.nme.2023.101552
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The ITER bolometer diagnostic will provide measurements of the total radiation emitted from the plasma, a part of the overall energy balance. It will consist of some 550 lines of sight (LOS) of bolometer detector, bundled in multiple individual cameras, which will be located in the gaps between blanket modules on the vacuum vessel wall, in five divertor cassettes, in two upper port plugs and in one equatorial port plug (Meister et al., 2017). The LOS are optimised as much as possible with design constraints to capture the details of different plasma regions in which the intensity and local distribution of radiation will vary over a large range. This is especially true in the divertor, where up to 70 % of the total thermal exhaust power from the core will have to be radiated during burning plasma operation. This radiation will be tightly concentrated meaning that not only will tomographic reconstruction of the distribution be challenging, but the bolometer cameras themselves need to be properly designed to handle the resulting heat fluxes. This paper first presents an assessment of the photonic heat fluxes falling on bolometers in the divertor region during high performance operation (where the heat fluxes will be highest). These heat fluxes are computed using ray-tracing from radiation distributions obtained with the SOLPS (plasma boundary region) and JINTRAC (plasma core region) codes and will serve as essential input to the thermal design studies of bolometers. The same SOLPS and JINTRAC simulations are used as models for the second focus of the paper which examines how closely the radiation distribution obtained from tomographic inversion of synthetic signals from the bolometer LOS matches the model input. Some effort has also been devoted to a study of how the reconstructions are affected by loss of individual LOS.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Assessment of a cooperative maintenance scheme for ITER divertor cooling pipes
    Friconneau, JP
    David, O
    Martins, JP
    Palmer, JD
    Tesini, A
    FUSION ENGINEERING AND DESIGN, 2005, 75-79 : 531 - 535
  • [32] Assessment of erosion and surface tritium inventory issues for the ITER divertor
    Argonne Natl Lab, Argonne, United States
    Journal of Nuclear Materials, 241-243 : 294 - 298
  • [33] Assessment of erosion and surface tritium inventory issues for the ITER divertor
    Brooks, JN
    Causey, R
    Federici, G
    Ruzic, DN
    JOURNAL OF NUCLEAR MATERIALS, 1997, 241 : 294 - 298
  • [34] Assessment of the He-cooled Test Divertor Module for ITER
    Widak, V.
    Norajitra, R.
    Boccaccini, L. V.
    Janeschitz, G.
    FUSION ENGINEERING AND DESIGN, 2008, 83 (7-9) : 1131 - 1136
  • [35] DIVERTOR ARMOUR ISSUES: LIFETIME, SAFETY AND INFLUENCE ON ITER PERFORMANCE
    Pestchanyi, S.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2009, (01): : 52 - 57
  • [36] Performance assessment of a tightly baffled, long-legged divertor configuration in TCV with SOLPS-ITER
    Sun, G.
    Reimerdes, H.
    Theiler, C.
    Duval, B. P.
    Carpita, M.
    Colandrea, C.
    Fevrier, O.
    NUCLEAR FUSION, 2023, 63 (09)
  • [37] Predictive Modeling for Performance Assessment of ITER-Like Divertor in China Fusion Engineering Testing Reactor
    Wang, Fuqiong
    Chen, Yiping
    Hu, Liqun
    Luo, Zhengping
    Li, Guoqiang
    Guo, Houyang
    Ye, Minyou
    JOURNAL OF FUSION ENERGY, 2015, 34 (05) : 1077 - 1087
  • [38] Predictive Modeling for Performance Assessment of ITER-Like Divertor in China Fusion Engineering Testing Reactor
    Fuqiong Wang
    Yiping Chen
    Liqun Hu
    Zhengping Luo
    Guoqiang Li
    Houyang Guo
    Minyou Ye
    Journal of Fusion Energy, 2015, 34 : 1077 - 1087
  • [39] Performance evaluation of tungsten for ITER divertor toward mass production
    Fukuda, M.
    Seki, Y.
    Ezato, K.
    Yokoyama, K.
    Nishi, H.
    Suzuki, S.
    Hirai, T.
    FUSION ENGINEERING AND DESIGN, 2021, 167
  • [40] ITER divertor performance in conditions of carbon re-erosion
    Kukushkin, AS
    Pacher, HD
    Coster, DP
    Pacher, GW
    Reiter, D
    JOURNAL OF NUCLEAR MATERIALS, 2005, 337 (1-3) : 50 - 54