Clinical application of artificial intelligence-assisted three-dimensional planning in direct anterior approach hip arthroplasty

被引:5
|
作者
Yang, Weihua [1 ]
Gao, Tianyi [2 ]
Liu, Xingyu [2 ]
Shen, Kaiwei [1 ]
Lin, Feitai [1 ]
Weng, Yan [1 ]
Lin, Bei [1 ]
Liang, Deng [1 ]
Feng, Eryou [3 ]
Zhang, Yiling [2 ]
机构
[1] Fuzhou Second Hosp, Dept Arthrosis Surg, Fuzhou, Peoples R China
[2] Longwood Valley MedTech, 2 Ronghua South Rd, Beijing, Peoples R China
[3] Fujian Med Univ, Union Hosp, Dept Ultrasound, 29 Xinquan Rd, Fuzhou 350001, Peoples R China
关键词
Total hip arthroplasty; 3D preoperative planning; Artificial intelligence; LEG LENGTH DISCREPANCY; ABDUCTOR MUSCLE STRENGTH; COMPLICATION RATE; RISK-FACTOR; FLUOROSCOPY; POSTERIOR; RELIABILITY; FAILURE;
D O I
10.1007/s00264-023-06029-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The objective of this study was to investigate the efficacy of an artificial intelligence-assisted 3D planning system (AIHIP) in total hip arthroplasty by direct anterior approach and assess the reliability of the AIHIP preoperative program in terms of both interobserver and intraobserver agreement.Methods A retrospective analysis was conducted on patients who underwent unilateral primary THA via direct anterior approach from June 2019 to March 2022. Participants were randomly assigned to receive either the AIHIP system (n = 220) or the 2D template (control group) (n = 220) for preoperative planning. The primary outcome aimed to evaluate the correspondence between the prosthesis selected intro-operation and the one planned preoperatively, as well as to calculate the intraclass correlation coefficient (ICC). Secondary outcomes included operation time, intraoperative blood loss, fluoroscopy times, Harris hip score (HHS), lower limb length difference (LLD), femoral offset (FO), and bilateral femoral offset difference.Results No significant differences were observed in gender, age, body mass index (BMI), aetiology, and American Society of Anesthesiologists (ASA) score between the two groups. Both planning methods exhibited good intraobserver agreement for component planning (ICC: 0.941-0.976). Interobserver agreement for component planning was comparable between the two methods (ICC: 0.882-0.929). In the AIHIP group, the accuracy of acetabular cup and femoral stem prosthetics planning significantly improved, with accuracies within the size range of +/- 0 and +/- 1 being 76.8% and 90.5% and 79.5% and 95.5%, respectively. All differences between two groups were statistically significant (p < 0.05). Patients receiving AIHIP preoperative planning experienced shorter operation times, reduced intraoperative blood loss, fewer fluoroscopy times, and lower leg length discrepancy (LLD) (p < 0.05). Moreover, they demonstrated a higher Harris hip score (HHS) at three days post-surgery (p < 0.05). However, no significant differences were found in femoral offset (FO), difference of bilateral femoral offsets, and HHS at 1 month after the operation.Conclusion Utilizing AIHIP for preoperative planning of direct anterior approach THA can significantly enhance the accuracy of prosthetic sizing with good reliability, decrease operation time, reduce intraoperative blood loss, and more effectively restore the length of both lower limbs. This approach has greater clinical application value.
引用
收藏
页码:773 / 783
页数:11
相关论文
共 50 条
  • [31] Functional Acetabular Component Positioning During Direct Anterior Approach Hip Arthroplasty Using a Novel Three-Dimensional Virtual Mesh Imaging System With Fluoroscopy
    Coxe, Francesca R.
    Jordan, L. Andrew
    Wong, Zachary P.
    Spaan, Jonathan C.
    Ren, Renee
    Su, Edwin P.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (09): : S88 - S96
  • [32] Research on the Application of Artificial Intelligence Technology in the Three-dimensional Teaching Field
    Xu, Xinglun
    2022 ASIA CONFERENCE ON ADVANCED ROBOTICS, AUTOMATION, AND CONTROL ENGINEERING (ARACE 2022), 2022, : 161 - 165
  • [33] Interobserver and Intraobserver Reliability of Three-Dimensional Preoperative Planning Software in Total Hip Arthroplasty
    Wako, Yasushi
    Nakamura, Junichi
    Miura, Michiaki
    Kawarai, Yuya
    Sugano, Masahiko
    Nawata, Kento
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02): : 601 - 607
  • [34] Three-dimensional printing for preoperative planning of total hip arthroplasty revision: case report
    Joseph Zerr
    Yonatan Chatzinoff
    Rajiv Chopra
    Kenneth Estrera
    Avneesh Chhabra
    Skeletal Radiology, 2016, 45 : 1431 - 1435
  • [35] Three-dimensional printing for preoperative planning of total hip arthroplasty revision: case report
    Zerr, Joseph
    Chatzinoff, Yonatan
    Chopra, Rajiv
    Estrera, Kenneth
    Chhabra, Avneesh
    SKELETAL RADIOLOGY, 2016, 45 (10) : 1431 - 1435
  • [36] Comparison of postoperative outcomes between endoscopy assisted minimal invasive direct anterior approach and bikini direct anterior approach in total hip arthroplasty
    Deng, Zhibo
    Dai, Hanhao
    Song, Chao
    Luo, Fenqi
    Wu, Yijing
    Zhang, Rongsheng
    Luo, Jun
    Xu, Jie
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (08) : 3705 - 3713
  • [37] Direct anterior approach for total hip arthroplasty: Hip biomechanics and muscle activation during three walking tasks
    Ippolito, Giorgio
    Serrao, Mariano
    Conte, Carmela
    Castiglia, Stefano Filippo
    Rucco, Ferdinando
    Bonacci, Enrico
    Miscusi, Massimo
    Pierelli, Francesco
    Bini, Fabiano
    Marinozzi, Franco
    Zitiello, Michele
    Ragona, Chiara
    De Marinis, Giancarlo
    CLINICAL BIOMECHANICS, 2021, 89
  • [38] Comparison of Three-Dimensional Planning-Assisted and Conventional Acetabular Cup Positioning in Total Hip Arthroplasty A Randomized Controlled Trial
    Sariali, Elhadi
    Boukhelifa, Nadia
    Catonne, Yves
    Moussellard, Hugues Pascal
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (02): : 108 - 116
  • [39] Three-dimensional pelvis computed tomography-assisted Taylor approach for spinal anesthesia in hip arthroplasty: a retrospective study
    Oh, Saecheol
    Park, Yoojung
    Kwoun, Hana
    Eom, Eunjin
    Kim, Dal-ah
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2023, 76 (01) : 12 - 16
  • [40] Comparison of clinical efficacy between direct anterior approach and posterolateral approach in primary total hip arthroplasty
    Jin, M. -W.
    Zhang, L.
    Chu, X. -B.
    Lv, S. J.
    Zhang, J. -J.
    Tong, P. -J.
    Pan, Y.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2023, 27 (12) : 5604 - 5613