Shaeer's infrapubic technique for penile prosthesis implantation through a single midline corporotomy: A single-center pilot study

被引:0
|
作者
Shaeer, Osama [1 ,2 ]
Shaeer, Kamal [1 ]
机构
[1] Cairo Univ, Kasr El Aini Fac Med, Dept Androl, Giza, Egypt
[2] 21 Gaber Ibn Hayan St,POB 12311 ARE, Giza, Egypt
来源
JOURNAL OF SEXUAL MEDICINE | 2023年 / 20卷 / 03期
关键词
penile prosthesis; penile implant; single corporotomy; infrapubic; dorsal nerve injury;
D O I
10.1093/jsxmed/qdac020
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
BackgroundWith the infrapubic approach (IPA) for penile prosthesis implantation, lateral corporotomies carry the risk of injury to the laterally coursing dorsal nerves.AimWe sought to describe for the first time Shaeer's IPA, a modification of the IPA whereby malleable penile prosthesis cylinders are implanted through a single midline corporotomy in the bed of the deep dorsal vein, anatomically off the course of the dorsal nerves of the penis.MethodsWe compared semirigid penile prosthesis implantation via the single midline corporotomy IPA (IPA-S, n = 11) to the classic IPA with laterally placed dual corporotomies (IPA-D, n = 11) and to the penoscrotal approach (PSA; n = 13). Shaeer's IPA is performed through an infrapubic incision. A 3- to 5-cm length of the deep dorsal vein is stripped. A single 3- to 5-cm midline corporotomy is cut along the bed of the vein. Dilation, sizing, and implantation are performed through the single corporotomy on either side of the midline septum. Patients are discharged the same day and are allowed to bend the implant after 2 weeks and to commence intercourse after 3 weeks.OutcomesOperative time, postoperative satisfaction, International Index of Erectile Function 5 (IIEF-5), and possible complications were recorded.ResultsThere were no statistically significant differences in age, postimplantation IIEF-5, or satisfaction between the 3 groups. Average operative time for the IPA-S group was 21.8% shorter than that for the IPA-D group, and 34.5% shorter than for the PSA group. Those differences were statistically significant. No complications were recorded in the IPA-S group. Infection occurred in 1 PSA case, and partial hypoesthesia in 1 IPA-D case.Clinical ImplicationsThe midline corporotomy confers an anatomical advantage that may help avoid nerve injury, thereby increasing the safety of the IPA.Strengths and LimitationsThe main limitation of this study is the limited sample number, considering that this is a pilot study.ConclusionThe Shaeer's Midline-Corporotomy IPA is a minimally invasive technique for implantation of a semirigid penile prosthesis, with an anatomical advantage that may decrease the possibility of dorsal nerve injury.
引用
收藏
页码:410 / 415
页数:6
相关论文
共 50 条
  • [41] Tocilizumab in VEXAS relapsing polychondritis: a single-center pilot study in Japan
    Kirino, Yohei
    Takase-Minegishi, Kaoru
    Tsuchida, Naomi
    Hirahara, Lisa
    Kunishita, Yosuke
    Yoshimi, Ryusuke
    Nakajima, Hideaki
    ANNALS OF THE RHEUMATIC DISEASES, 2021, 80 (11) : 1501 - 1502
  • [42] A retrospective single-center pilot study of the genetic background of the transplanted kidney
    Novotna, Anna
    Horackova, Klara
    Soukupova, Jana
    Zemankova, Petra
    Nehasil, Petr
    Just, Pavel
    Voska, Ludek
    Kleiblova, Petra
    Bloudickova, Silvie Rajnochova
    PLOS ONE, 2025, 20 (01):
  • [43] Milk Oral Immunotherapy: A Single-Center Pilot Study of Safety and Efficacy
    Saltzman, R. W.
    Kelleher, M.
    Brown-Whitehorn, T.
    Fiedler, J.
    Corry, J.
    Gober, L.
    Dudek, E.
    Cianferoni, A.
    Spergel, J.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2012, 129 (02) : AB25 - AB25
  • [44] COMPARISON OF PENILE PROSTHESES OUTCOMES IN VETERANS WITH PEYRONIE'S DISEASE: A SINGLE-CENTER ANALYSIS
    Handing, G.
    Park, B.
    Patel, S.
    Jones, J.
    Srikishen, N.
    Khera, M.
    JOURNAL OF SEXUAL MEDICINE, 2023, 20
  • [45] Robotic Freyer's prostatectomy: Operative technique and single-center experience
    Waigankar, Santosh S.
    Yuvaraja, Thyavihally B.
    Dev, Preetham
    Agarwal, Varun
    Pednekar, Abhinav P.
    Kulkarni, Bijal
    INDIAN JOURNAL OF UROLOGY, 2021, 37 (03) : 247 - 253
  • [46] Outcome and satisfaction rates of three-piece penile prosthesis implantation for treatment of erectile dysfunction: single center experience
    Tomada, N.
    Lopes, I
    Diniz, P.
    Guimaraes, M.
    Vendeira, P.
    JOURNAL OF SEXUAL MEDICINE, 2008, 5 : 121 - 121
  • [47] SIMULTANEOUS VIRTUE MALE SLING AND TITAN INFLATABLE PENILE PROSTHESIS: SINGLE CENTER PATIENT SATISFACTION AND SURGICAL TECHNIQUE
    McCool, Alan
    JOURNAL OF SEXUAL MEDICINE, 2012, 9 : 30 - 31
  • [48] Analysis of complications in transfemoral transcatheter aortic valve implantation: a single-center study
    Pylko, Anna
    Dabrowski, Maciej
    Kowalik, Ilona
    Chmielak, Zbigniew
    Kukula, Krzysztof
    Wolny, Rafal
    Kwiecinski, Jacek
    Stoklosa, Patrycjusz
    Grabowski, Maciej
    Michalowska, Ilona
    Kusmierski, Krzysztof
    Witkowski, Adam
    POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2024, 134 (04):
  • [49] Comparison of the patient's satisfaction underwent penile prosthesis; Malleable versus Ambicor: Single center experience
    Bayrak, Omer
    Erturhan, Sakip
    Seckiner, Ilker
    Ozturk, Mehmet
    Sen, Haluk
    Erbagci, Ahmet
    ARCHIVIO ITALIANO DI UROLOGIA E ANDROLOGIA, 2020, 92 (01) : 25 - 29
  • [50] Left ventricular assist device implantation by bi-thoracotomy technique: A single-center perspective
    Stoeckl, Elizabeth M.
    Smith, Jason W.
    Dhingra, Ravi
    Fiedler, Amy G.
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (07) : 2342 - 2347