An MSA-Net Algorithm for Direct Estimation of Gas Holdup Based on Electrical Impedance Tomography System

被引:0
|
作者
Zhang, Hanyu [1 ]
Hu, Jingyi [2 ]
Li, Nan [2 ]
机构
[1] Northwestern Polytech Univ, Adv Intelligent Measurement & Control & Nav Techno, Xian 710129, Shaanxi, Peoples R China
[2] Northwestern Polytech Univ, Sch Automat, Xian 710129, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Estimation; Feature extraction; Voltage measurement; Image reconstruction; Electrical impedance tomography; Imaging; Deep learning; Cross-sectional gas-holdup ratio (CGR); deep learning; direct estimation; electrical impedance tomography (EIT); MASS-TRANSFER; IDENTIFICATION;
D O I
10.1109/JSEN.2023.3256643
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical impedance tomography (EIT) is a nondestructive testing technique, which has great potential to be used for the detection of the cross-sectional gas-holdup ratio (CGR) of gas-liquid two-phase flow. Due to the nonlinear and ill-posed characteristics of the EIT image reconstruction, the accuracy of image-based CGR estimation methods is poor. To improve the detection accuracy, a learning-based direct CGR estimation method is proposed in this study, which applies a novel multiscale attention network (MSA-Net) to directly estimate the CGR from the voltage measurements. Multiscale feature extraction and residual structure are introduced into MSA-Net to fully extract the features, and attention unit (AU) is also used to capture high-frequency features. As a result, accurate and robust CGR estimation can be realized by MSA-Net. ResNet18 and single-scale attention network (SSA-Net) are selected for comparison. The simulation results indicate that the relative error (RECG) of CGR estimated by the learning-based direct CGR estimation method is far lower than that of the image-based CGR estimation methods. Compared with ResNet18 and SSA-Net, the RECG of the CGR estimated by MSA-Net is lower, and the range is 0.07%-0.36%. Moreover, MSA-Net shows good noise robustness simultaneously. The experiment is also set to test MSA-Net. The range of RECG is 0.1%-1.12%, which further verifies the practicability of the proposed learning-based direct CGR estimation method.
引用
收藏
页码:8680 / 8689
页数:10
相关论文
共 50 条
  • [21] A PXI-Based Biomedical Electrical Impedance Tomography System
    Chen, Xiaoyan
    Yang, Tao
    Yang, Yongzheng
    APPLIED MECHANICS, MATERIALS AND MANUFACTURING IV, 2014, 670-671 : 1205 - 1209
  • [22] An Image Reconstruction Algorithm for Electrical Impedance Tomography Using Measurement Estimation of Virtual Electrodes
    Yang, Lu
    Wu, Hongtao
    Liu, Kai
    Chen, Bai
    Yang, Yunjie
    Zhu, Chengjun
    Yao, Jiafeng
    IEEE SENSORS JOURNAL, 2022, 22 (13) : 13012 - 13022
  • [23] An In Situ Electrical Impedance Tomography Sensor System for Biomass Estimation of Tap Roots
    Basak, Rinku
    Wahid, Khan A.
    PLANTS-BASEL, 2022, 11 (13):
  • [24] U-Net-based approach for automatic lung segmentation in electrical impedance tomography
    Ko, Yen-Fen
    Cheng, Kuo-Sheng
    PHYSIOLOGICAL MEASUREMENT, 2021, 42 (02)
  • [25] Comments on "Algorithm for tissue ischemia estimation based on electrical impedance spectroscopy"
    Grimnes, Sverre
    Martinsen, Orjan G.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (02) : 344 - 344
  • [26] Direct estimation of gas holdup in gas-liquid bubble column reactors using ultrasonic transmission tomography and artificial neural processing
    Hu, Jingyi
    Li, Nan
    Wang, Lina
    Yang, Peng
    Yang, Yunjie
    Quan, Yihong
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (07)
  • [27] Adaptive mesh refinement algorithm for electrical impedance tomography based on wavelet transform
    Peng, Y
    Mo, YL
    IEEE EMBS APBME 2003, 2003, : 196 - 197
  • [28] Research on the Method of Electrical Impedance Tomography Based on Conjugate Gradient Iterative Algorithm
    Yue, Yuanli
    Chen, Xiaoyan
    Liu, Ze
    Dai, Fengzhi
    ICAROB 2018: PROCEEDINGS OF THE 2018 INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS, 2018, : 607 - 612
  • [29] Quasi-Newton algorithm for electrical impedance tomography - a switch algorithm based on modified Bk
    2000, Beijing Inst Heart Lung Blood Vessel Dis, Beijing, China (19):
  • [30] Electrical Impedance Tomography Based on Vibration Excitation in Magnetic Resonance System
    Li, Shi-qiang
    Liu, Guo-qiang
    Xin, Xue-gang
    Wang, Xin-li
    2016 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND AUTOMATION (ICEEA 2016), 2016,