Reliable Detection Method of Variable Series Arc Fault in Building Integrated Photovoltaic Systems Based on Nonstationary Time Series Analysis

被引:11
|
作者
Chen, Silei [1 ]
Wu, Hancong [2 ]
Meng, Yu [2 ]
Wang, Yuanfeng [1 ]
Li, Xingwen [2 ]
Zhang, Chenjia [1 ]
机构
[1] Xian Univ Technol, Sch Elect Engn, Xian 710048, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Feature extraction; Time series analysis; Time-frequency analysis; Fault detection; Reliability; Energy storage; Harmonic analysis; Atypical series arc fault; building integrated photovoltaic (BIPV) systems; nonstationary time series analysis; parameter match; time--frequency characteristics; ALGORITHM;
D O I
10.1109/JSEN.2023.3256009
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Arc fault characteristics would be influenced by diverse system elements and operation levels in building integrated photovoltaic (BIPV) systems, which would challenge the arc fault detection. This article aims at improving the detection reliability and speed by applying the time series analysis at feature and classification layers to reflect the random evolution process of arc fault current. According to the arc ignition method in UL1699B, arc fault signals are first sampled with a residential storage element and ten dc load elements at three voltage levels in BIPV systems. After evaluating time-frequency information with established indexes, variable and early arc fault are discovered to have no obvious current and harmonic indications due to strong system element noises, sensor precision, and low arc energy. Then, the sample entropy (SE) feature and gated recurrent unit (GRU) classifier are proposed to improve the detection performance through involving the nonstationary time series correlation of the arc fault current. An arc fault simulation platform is built to generate arc current with low signal-to-noise ratio (SNR), which proves the detection algorithm integrates multisource information to grasp the appearance of new signal pattern. Next, constrained optimization problems are designed for both feature and classifier layers to achieve the most distinguishable arc fault and fault-like performance. With matched optimization methods, the modified SE and GRU method could improve the detection accuracy by an average of 21.08% after comparing with existing features and classifiers. Finally, hardware implementation results indicate a higher detection accuracy and less runtime of the proposed detection method.
引用
收藏
页码:8654 / 8664
页数:11
相关论文
共 50 条
  • [31] A DC Arc Fault Detection Method Based on AR Model for Photovoltaic Systems
    Wang, Yao
    Li, Xiang
    Ban, Yunsheng
    Ma, Xiaochen
    Hao, Chenguang
    Zhou, Jiawang
    Cai, Huimao
    APPLIED SCIENCES-BASEL, 2022, 12 (20):
  • [32] Series Arc Fault Detection Using Regular Signals and Time-Series Reconstruction
    Jiang, Run
    Zheng, Yuesheng
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (02) : 2026 - 2036
  • [33] DC Series Arc Fault Detection Method With Resonant Filter Design for PV Systems
    Park, Hwa-Pyeong
    Chang, Seung-Jin
    Park, Jae-Young
    Kim, Mina
    Kim, Wan
    Chae, Suyong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (11) : 14240 - 14250
  • [34] A new method for nonlinear and nonstationary time series analysis
    Huang, NE
    Shen, Z
    Long, SR
    Huang, MJ
    STOCHASTIC STRUCTURAL DYNAMICS, 1999, : 559 - 564
  • [35] Photovoltaic DC Series Arc Fault Identification Method Based on Precise Noise Reduction Algorithm
    Zhang, Chunjiang
    Kang, Ziliang
    Lv, Changhao
    Jia, Qingquan
    IEEE SENSORS JOURNAL, 2024, 24 (04) : 4746 - 4757
  • [36] DC Series Arc Fault Detection Using Machine Learning in Photovoltaic Systems: Recent Developments and Challenges
    Lu, Shibo
    Sahoo, Animesh
    Ma, Rui
    Phung, B. T.
    2020 8TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD 2020), 2020, : 416 - 421
  • [37] A Series DC Arc Fault Detection Method and Hardware Implementation
    Yao, Xiu
    Herrera, Luis
    Wang, Jin
    2013 TWENTY-EIGHTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2013), 2013, : 2444 - 2449
  • [38] Identification technique of DC series arc-fault strings in photovoltaic systems
    Kanemaru, Makoto
    Kokura, Kentaro
    Mori, Mitsugi
    Shindoi, Takashi
    Yamamoto, Masato
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 2019, 207 (02): : 12 - 19
  • [39] Study on DC Series Arc Fault in Photovoltaic Systems for Condition Monitoring Purpose
    Lu, Shibo
    Phung, B. T.
    Zhang, Daming
    2017 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2017,
  • [40] Identification technique of DC series arc-fault strings in photovoltaic systems
    Kanemaru M.
    Kokura K.
    Mori M.
    Shindoi T.
    Yamamoto M.
    IEEJ Transactions on Power and Energy, 2019, 139 (01): : 39 - 45