Impact of half-wave plate systematics on the measurement of cosmic birefringence from CMB polarization

被引:8
|
作者
Monelli, Marta [1 ]
Komatsu, Eiichiro [1 ,2 ]
Adler, Alexandre E. [3 ]
Billi, Matteo [4 ,5 ,6 ]
Campeti, Paolo [1 ,7 ]
Dachlythra, Nadia [3 ]
Duivenvoorden, Adriaan J. [8 ,9 ]
Gudmundsson, Jon E. [3 ,10 ]
Reinecke, Martin [1 ]
机构
[1] Max Planck Inst Astrophys, Karl Schwarzschild Str 1, D-85748 Garching, Germany
[2] Univ Tokyo, Kavli Inst Phys & Math Universe Kavli IPMU, WPI, UTIAS, Chiba 2778583, Japan
[3] Stockholm Univ, Oskar Klein Ctr, Dept Phys, SE-10691 Stockholm, Sweden
[4] CSIC UC, Inst Fis Cantabria IFCA, Ave Castros S-n, Santander 39005, Spain
[5] Alma Mater Studiorum Univ Bologna, Dipartimento Fis & Astron, Via Gobetti 93-2, I-40129 Bologna, Italy
[6] Ist Nazl Astrofis Osservatorio Astrofis & Sci Spaz, Via Gobetti 101, I-40129 Bologna, Italy
[7] Excellence Cluster ORIGINS, Boltzmannstr 2, D-85748 Garching, Germany
[8] Flatiron Inst, Ctr Computat Astrophys, 162 5th Ave, New York, NY 10010 USA
[9] Princeton Univ, Joseph Henry Labs Phys, Jadwin Hall, Princeton, NJ 08544 USA
[10] Univ Iceland, Sci Inst, Dunhaga 3, IS-107 Reykjavik, Iceland
基金
欧洲研究理事会;
关键词
CMBR experiments; CMBR polarisation; SKY BEAM CONVOLUTION; INFLATIONARY UNIVERSE; GRAVITY-WAVES; MICROWAVE; SIGNATURE; FLATNESS; HORIZON;
D O I
10.1088/1475-7516/2023/03/034
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Polarization of the cosmic microwave background (CMB) can probe new parity-violating physics such as cosmic birefringence (CB), which requires exquisite control over instrumental systematics. The non-idealities of the half-wave plate (HWP) represent a source of systematics when used as a polarization modulator. We study their impact on the CMB angular power spectra, which is partially degenerate with CB and miscalibration of the polarization angle. We use full-sky beam convolution simulations including HWP to generate mock noiseless time-ordered data, process them through a bin averaging map-maker, and calculate the power spectra including TB and EB correlations. We also derive analytical formulae which accurately model the observed spectra. For our choice of HWP parameters, the HWP-induced angle amounts to a few degrees, which could be misinterpreted as CB. Accurate knowledge of the HWP is required to mitigate this. Our simulation and analytical formulae will be useful for deriving requirements for the accuracy of HWP calibration.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] CMB polarization systematics, cosmological birefringence, and the gravitational waves background
    Pagano, Luca
    de Bernardis, Paolo
    De Troia, Grazia
    Gubitosi, Giulia
    Masi, Silvia
    Melchiorri, Alessandro
    Natoli, Paolo
    Piacentini, Francesco
    Polenta, Gianluca
    PHYSICAL REVIEW D, 2009, 80 (04):
  • [22] Maxipol: Cosmic microwave background polarimetry using a rotating half-wave plate
    Johnson, B. R.
    Collins, J.
    Abroe, M. E.
    Ade, P. A. R.
    Bock, J.
    Borrill, J.
    Boscaleri, A.
    de Bernardis, P.
    Hanany, S.
    Jaffe, A. H.
    Jones, T.
    Lee, A. T.
    Levinson, L.
    Matsumura, T.
    Rabii, B.
    Renbarger, T.
    Richards, P. L.
    Smoot, G. F.
    Stompor, R.
    Tran, H. T.
    Winant, C. D.
    Wu, J. H. P.
    Zuntz, J.
    ASTROPHYSICAL JOURNAL, 2007, 665 (01): : 42 - 54
  • [23] Simultaneous determination of the cosmic birefringence and miscalibrated polarization angles from CMB experiments
    Minami, Yuto
    Ochi, Hiroki
    Ichiki, Kiyotomo
    Katayama, Nobuhiko
    Komatsu, Eiichiro
    Matsumura, Tomotake
    PROGRESS OF THEORETICAL AND EXPERIMENTAL PHYSICS, 2019, 2019 (08):
  • [24] Demonstration of the broadband half-wave plate using the nine-layer sapphire for the cosmic microwave background polarization experiment
    Komatsu, Kunimoto
    Matsumura, Tomotake
    Imada, Hiroaki
    Ishino, Hirokazu
    Katayama, Nobuhiko
    Sakurai, Yuki
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2019, 5 (04)
  • [25] A MICROWAVE ANALOG OF A HALF-WAVE PLATE
    PELSOR, GT
    AMERICAN JOURNAL OF PHYSICS, 1949, 17 (04) : 223 - 224
  • [26] Ultrafast gaseous "half-wave plate"
    Bejot, P.
    Petit, Y.
    Bonacina, L.
    Kasparian, J.
    Moret, M.
    Wolf, J. -P.
    OPTICS EXPRESS, 2008, 16 (10) : 7564 - 7570
  • [27] Broadband Birefringent Half-Wave Plate
    Ou, Yaw-Ren
    Lin, Tsung-Hsien
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2009, 48 (10) : 1024011 - 1024018
  • [28] Intensity-coupled Polarization in Instruments with a Continuously Rotating Half-wave Plate
    Didier, Joy
    Miller, Amber D.
    Araujo, Derek
    Aubin, Francois
    Geach, Christopher
    Johnson, Bradley
    Korotkov, Andrei
    Raach, Kate
    Westbrook, Benjamin
    Young, Karl
    Aboobaker, Asad M.
    Ade, Peter
    Baccigalupi, Carlo
    Bao, Chaoyun
    Chapman, Daniel
    Dobbs, Matt
    Grainger, Will
    Hanany, Shaul
    Helson, Kyle
    Hillbrand, Seth
    Hubmayr, Johannes
    Jaffe, Andrew
    Jones, Terry J.
    Klein, Jeff
    Lee, Adrian
    Limon, Michele
    MacDermid, Kevin
    Milligan, Michael
    Pascale, Enzo
    Reichborn-Kjennerud, Britt
    Sagiv, Ilan
    Tucker, Carole
    Tucker, Gregory S.
    Zilic, Kyle
    ASTROPHYSICAL JOURNAL, 2019, 876 (01):
  • [29] Broadband terahertz half-wave plate based on anisotropic polarization conversion metamaterials
    Xia, Rui
    Jing, Xufeng
    Gui, Xincui
    Tian, Ying
    Hong, Zhi
    OPTICAL MATERIALS EXPRESS, 2017, 7 (03): : 977 - 988
  • [30] Improved measurements of thermally induced birefringence effects in a laser material using a half-wave plate
    Kim, Duck-Lae
    Kim, Byung-Tai
    OPTICS COMMUNICATIONS, 2010, 283 (24) : 5111 - 5116