Image-based robotic unicompartmental knee arthroplasty allowed to match the rotation of the tibial implant with the native kinematic knee alignment

被引:12
|
作者
Favroul, Clement [1 ]
Batailler, Cecile [1 ,2 ]
Canetti, Robin [1 ]
Shatrov, Jobe [1 ,3 ]
Zambianchi, Francesco [4 ]
Catani, Fabio [4 ]
Servien, Elvire [1 ,5 ]
Lustig, Sebastien [1 ,2 ]
机构
[1] Lyon Univ Hosp, Croix Rousse Hosp, FIFA Med Ctr Excellence, Orthopaed Surg & Sports Med Dept, Lyon, France
[2] Claude Bernard Lyon 1 Univ, Univ Lyon, IFSTTAR, LBMC UMR T9406, F-69622 Lyon, France
[3] Univ Notre Dame Australia, Hornsby & Ku Ring Hosp, Sydney Orthopaed Res Inst, Sydney, NSW, Australia
[4] Univ Modena & Reggio Emilia, Azienda Osped Univ Modena, Dept Orthopaed Surg, Via Pozzo 71, I-41124 Modena, Italy
[5] Claude Bernard Lyon 1 Univ, Interuniv Lab Biol Mobil, LIBM EA 7424, Lyon, France
关键词
Unicompartmental knee arthroplasty; Image-based robotic assisted system; Screw home mechanism; Implant rotation; Kinematic alignment; FOLLOW-UP; COMPONENT; MOVEMENT; ANATOMY; BEARING;
D O I
10.1007/s00264-022-05637-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Image-based robotic tools improve the accuracy of unicompartmental knee arthroplasty (UKA) positioning, but few studies have examined its effect on axial alignment. The aim of this study was to compare the characteristics of tibial and femoral implant positioning, mainly the tibial rotation, during medial or lateral UKA, performed with an image-based robotic assisted system. Methods A total of 71 UKA performed between September 2021 and June 2022 (53 medial and 18 lateral) were analyzed. All data regarding implant positioning (rotation, coronal and sagittal alignment) for tibial and femoral components were obtained using MAKO (R) software (Stryker (R), Mahwah, USA) intra-operatively. Results The lateral UKA had a mean internal tibial rotation of 15.4 +/- 3 degrees, a mean external femoral rotation of 0.96 +/- 2.4 degrees, and a mean tibial slope of 4.7 +/- 1.3 degrees. The medial UKA had a mean internal tibial rotation of 0.18 +/- 2.7 degrees, a mean internal femoral rotation of 0.35 +/- 2.2 degrees, and a mean tibial slope of 5.4 +/- 1.3 degrees. The tibial rotations, femoral valgus, tibial varus and tibial size significantly differed between medial and lateral UKA (p < 0.05). There was no significant difference in femoral rotation, flexion, femoral size, slope, and polyethylene thickness between medial and lateral UKA. Conclusion Medial and lateral UKA had significantly different implantation characteristics related to the biomechanics of the knee compartments. Image-based robotic UKA allowed precise femorotibial positioning per-operatively to match native kinematic alignment.
引用
收藏
页码:519 / 526
页数:8
相关论文
共 50 条
  • [41] ROBOTIC-ARM-ASSISTED LATERAL UNICOMPARTMENTAL KNEE ARTHROPLASTY WITH A FIXED-BEARING IMPLANT
    Premkumar, Ajay
    Bayoumi, Tarik
    Pearle, Andrew D.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2023, 13 (02):
  • [42] Improved implant position and lower revision rate with robotic-assisted unicompartmental knee arthroplasty
    Cécile Batailler
    Nathan White
    Filippo Maria Ranaldi
    Philippe Neyret
    Elvire Servien
    Sébastien Lustig
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1232 - 1240
  • [43] Improved implant position and lower revision rate with robotic-assisted unicompartmental knee arthroplasty
    Batailler, Cecile
    White, Nathan
    Ranaldi, Filippo Maria
    Neyret, Philippe
    Servien, Elvire
    Lustig, Sebastien
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) : 1232 - 1240
  • [44] Fixed-bearing unicompartmental knee arthroplasty tolerates higher variance in tibial implant rotation than mobile-bearing designs
    Ozcan, Cem
    Simsek, Mehmet Emin
    Tahta, Mesut
    Akkaya, Mustafa
    Gursoy, Safa
    Bozkurt, Murat
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (10) : 1463 - 1469
  • [45] Fixed-bearing unicompartmental knee arthroplasty tolerates higher variance in tibial implant rotation than mobile-bearing designs
    Cem Ozcan
    Mehmet Emin Simsek
    Mesut Tahta
    Mustafa Akkaya
    Safa Gursoy
    Murat Bozkurt
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 1463 - 1469
  • [46] Kinematic alignment technique for total hip and knee arthroplasty: the personalized implant positioning surgery
    Riviere, Charles
    Lazic, Stefan
    Villet, Loic
    Wiart, Yann
    Allwood, Sarah Muirhead
    Cobb, Justin
    EFORT OPEN REVIEWS, 2018, 3 (03): : 98 - 105
  • [47] Effects of Lower Limb Alignment and Tibial Component Inclination on the Biomechanics of Lateral Compartment in Unicompartmental Knee Arthroplasty
    Wen, Peng-Fei
    Guo, Wan-Shou
    Gao, Fu-Qiang
    Zhang, Qi-Dong
    Yue, Ju-An
    Cheng, Li-Ming
    Zhu, Guang-Duo
    CHINESE MEDICAL JOURNAL, 2017, 130 (21) : 2563 - 2568
  • [48] The effect of tibial component rotational alignment on clinical outcomes of mobile-bearing unicompartmental knee arthroplasty
    Xiaoqiang Zhou
    Chao Sun
    Renjie Xu
    Xiangxin Zhang
    Xiao Yu
    Journal of Orthopaedic Surgery and Research, 18
  • [49] The effect of tibial component rotational alignment on clinical outcomes of mobile-bearing unicompartmental knee arthroplasty
    Zhou, Xiaoqiang
    Sun, Chao
    Xu, Renjie
    Zhang, Xiangxin
    Yu, Xiao
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [50] No Difference in Limb Alignment Between Kinematic and Mechanical Alignment Robotic-Assisted Total Knee Arthroplasty
    Karasavvidis, Theofilos
    Pagan, Cale A.
    Debbi, Eytan M.
    Mayman, David J.
    Jerabek, Seth A.
    Vigdorchik, Jonathan M.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (08): : S204 - S209