Pressure-sensitive paint measurements on the cavity with passive control devices under transonic flow

被引:1
|
作者
Ouyang, Jun-Kai [1 ]
Liao, Yi-Ting [2 ]
Hsu, Yen-Ting [2 ]
Lee, Cheng-Chi [2 ]
Lin, Yu-Hung [3 ]
Chen, Chung-Lung [3 ,4 ]
Wang, Wei-Hsiang [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Mech Engn, Taichung, Taiwan
[2] Natl Chung Shan Inst Sci & Technol, Dept Aerodynam, Aeronaut Syst Res Div, Taichung, Taiwan
[3] Natl Yang Ming Chiao Tung Univ, Dept Mech Engn, Hsinchu, Taiwan
[4] Univ Missouri, Dept Mech & Aerosp Engn, Columbia, MO USA
关键词
cavity flow; pressure-sensitive paints; oil flow visualization;
D O I
10.1093/jom/ufad023
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
In this study, the pressure-sensitive paint (PSP) technique, specifically the mesoporous-particle-based PSP, was employed to compare rectangular cavities with varying length-to-depth ratios (L/D) and different trailing edge shapes under transonic conditions. By utilizing PSP, comprehensive and quantitative pressure data were obtained, enabling the simultaneous observation of surface flow field distribution. The results obtained using PSP were found to be consistent with those obtained from conventional pressure sensors. The study revealed that the pressure distribution within the cavities changed with increasing L/D, and cavities with different trailing edge shapes demonstrated a reduction in pressure at the bottom region. Furthermore, the comparison of results obtained through the oil flow method corroborated the PSP findings, indicating that a beveled or sawtooth-shaped trailing edge of the cavity induced air flow deflection, effectively disrupting the upstream shear flow structure and altering the pressure distribution at the cavity's bottom.
引用
收藏
页码:280 / 291
页数:12
相关论文
共 50 条
  • [21] Reduction of Temperature Effects in Pressure-Sensitive Paint Measurements
    Egami, Y.
    Fujii, K.
    Takagi, T.
    Matsuda, Y.
    Yamaguchi, H.
    Niimi, T.
    AIAA JOURNAL, 2013, 51 (07) : 1779 - 1783
  • [22] Fast Pressure-Sensitive Paint for Flow and Acoustic Diagnostics
    Gregory, James W.
    Sakaue, Hirotaka
    Liu, Tianshu
    Sullivan, John P.
    ANNUAL REVIEW OF FLUID MECHANICS, VOL 46, 2014, 46 : 303 - 330
  • [23] Temperature- and pressure-sensitive paint measurements in short-duration hypersonic flow
    Hubner, JP
    Carroll, BF
    Schanze, KS
    Ji, HF
    Holden, MS
    AIAA JOURNAL, 2001, 39 (04) : 654 - 659
  • [24] Super-hydrophobic porous pressure-sensitive paint for global unsteady flow measurements
    Sakaue, Hirotaka
    Kodama, Hiroyuki
    Morita, Katsuaki
    Ishikawa, Hitoshi
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 185 : 154 - 158
  • [25] Accuracy of pressure-sensitive paint
    Liu, TS
    Guille, M
    Sullivan, JP
    AIAA JOURNAL, 2001, 39 (01) : 103 - 112
  • [26] Limiting Mach number for quantitative pressure-sensitive paint measurements
    Mendoza, DR
    AIAA JOURNAL, 1997, 35 (07) : 1240 - 1241
  • [27] PRESSURE-SENSITIVE PAINT MEASUREMENTS IN NARROW CLEARANCES: A FEASIBILITY STUDY
    Zimmermann, Anna-L.
    Graiff, Mattia
    Tran, Q. Tue Nguyen
    Guemmer, Volker
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2019, VOL 6, 2019,
  • [28] Bridging the Gap between Pressure-Sensitive Paint and Balance Measurements
    Ruyten, Wim
    Bell, James H.
    AIAA JOURNAL, 2010, 48 (03) : 591 - 597
  • [29] Pressure-sensitive paint on a truncated cone in hypersonic flow at incidences
    Yang, L.
    Erdem, E.
    Zare-Behtash, H.
    Kontis, K.
    Saravanan, S.
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2012, 37 : 9 - 21
  • [30] Comparison of Passive Flow Control Methods for a Cavity in Transonic Flow
    Saddington, A. J.
    Thangamani, V.
    Knowles, K.
    JOURNAL OF AIRCRAFT, 2016, 53 (05): : 1439 - 1447