Real-time biosensor application of structurally chiral medium for detection and sensing of plasma in human blood

被引:1
|
作者
Ghorani, Nadia [1 ]
Madani, Amir [1 ]
Entezar, Samad Roshan [2 ]
机构
[1] Univ Bonab, Dept Laser & Opt Engn, Bonab, Iran
[2] Univ Tabriz, Fac Phys, Tabriz, Iran
关键词
structurally chiral medium; blood plasma; circularly polarized light; photonic bandgap; transfer matrix method; biosensor; LABEL-FREE DETECTION; PHOTONIC CRYSTAL; WHOLE-BLOOD; WAVE-GUIDE; REFLECTION; SENSOR; PLATFORM; OPTICS; LIGHT; BAND;
D O I
10.1088/1402-4896/accc5c
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In this work, we theoretically investigated a unique and sensitive optical biosensor for detecting and sensing blood plasma using a structurally chiral medium. The proposed biosensor is a defective one-dimensional structure made from a structurally chiral material with (4) over bar 2m point group symmetry where the defect layer is considered as a channel for the blood plasma. The transmission and reflection of the structure are investigated utilizing the transfer matrix method for the circularly polarized waves. It is shown that a defect mode is created in the middle of the circular Bragg photonic band gap for the right-handed circularly polarized waves and experiences a red shift by increasing the blood plasma concentration. Also, it is observed that the sensitivity of the sensor can be increased by increasing the thickness of the defect layer. In addition, we reveal that the increase of the tilt angle of the structurally chiral medium results in the decrease of photonic band gap width and causes to blue-shift of the defect mode. As a result, the performance of the sensor decreases by increasing the tilt angle. The proposed structure has an easy and efficient manufacturing process, high stability and cost-effectiveness and can provide real-time blood plasma biosensors.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Real-time Time Synchronization Detection System application and Analysis
    Qu Gang
    Bi Xiaoliang
    Ge Zhaoqiang
    Zhang Peihong
    Yuan Hao
    AUTOMATIC CONTROL AND MECHATRONIC ENGINEERING III, 2014, 615 : 135 - +
  • [42] Real-time bacterial detection with an intracellular ROS sensing platform
    Hicks, J. M.
    Halkerston, R.
    Silman, N.
    Jackson, S. K.
    Aylott, J. W.
    Rawson, F. J.
    BIOSENSORS & BIOELECTRONICS, 2019, 141
  • [43] A liquid dielectric sensing methodology for real-time detection of disinfectants
    Liu, Jiachen
    Yi, Wei
    Cheng, Zhongyang
    2022 IEEE 21ST INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2022,
  • [44] Real-time cloud detection in optical remote sensing image
    Yan, Yu-Song
    Long, Teng
    Beijing Ligong Daxue Xuebao/Transaction of Beijing Institute of Technology, 2010, 30 (07): : 817 - 821
  • [45] CORNER DETECTION FOR REAL-TIME MOBILE IMAGING APPLICATION
    Habib, Nusrat
    Hunt, Martin A.
    2013 IEEE GLOBAL CONFERENCE ON SIGNAL AND INFORMATION PROCESSING (GLOBALSIP), 2013, : 747 - 750
  • [46] Real-Time Ultralow Bacterial Detection With A Gap-Method Microcantilever Biosensor
    Fathy, Jino
    Jia, Zongchao
    Lai, Yongjun
    IEEE SENSORS JOURNAL, 2024, 24 (02) : 1313 - 1321
  • [47] Love wave biosensor for real-time detection of okadaic acid as DSP phycotoxin
    Fournel, F.
    Baco, E.
    Mamani-Matsuda, M.
    Degueil, M.
    Bennetau, B.
    Moynet, D.
    Mossalayi, D.
    Vellutini, L.
    Pillot, J. -P.
    Dejous, C.
    Rebiere, D.
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 831 - 834
  • [48] Real-Time Biomolecular Binding Detection Using a Sensitive Photonic Crystal Biosensor
    Guo, Yunbo
    Ye, Jing Yong
    Divin, Charles
    Huang, Baohua
    Thomas, Thommey P.
    Baker, James R., Jr.
    Norris, Theodore B.
    ANALYTICAL CHEMISTRY, 2010, 82 (12) : 5211 - 5218
  • [49] Smart Textile Electrochemical Capacitive Biosensor for Real-Time Monkeypox Virus Detection
    de Lima, Lucas F.
    Corsato, Paula C. R.
    Beluomini, Maisa A.
    Ferreira, Andre L.
    Santos, Leticia Esterdos
    Barbosa, Priscilla P.
    Simeoni, Camila L.
    de Jesus, Marcelo Bispo
    Proenca-Modena, Jose Luiz
    Paixao, Thiago R. L. C.
    de Araujo, William R.
    ACS APPLIED ELECTRONIC MATERIALS, 2025, 7 (07) : 2882 - 2893
  • [50] Love wave biosensor for real-time detection of okadaic acid as DSP phycotoxin
    Fournel, F.
    Baco, E.
    Mamani-Matsuda, M.
    Degueil, M.
    Bennetau, B.
    Moynet, D.
    Mossalayi, D.
    Vellutini, L.
    Pillot, J. -P.
    Dejous, C.
    Rebiere, D.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 170 : 122 - 128