Predicting the bond strength between steel wire and mortar based on interfacial porosity and shrinkage

被引:2
|
作者
Zheng, Xuan [1 ]
Zhang, Chi [1 ]
Gao, Shengzhe [1 ]
Wang, Fangzheng [1 ]
机构
[1] Hebei Univ, Coll Civil Engn & Architecture, 180 Wusi East Rd, Baoding 071002, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Interfacial porosity; Shrinkage; Bond strength; BSE observing; Nanoindentation test; ENGINEERED CEMENTITIOUS COMPOSITE; PERFORMANCE; CONCRETE; MICROSTRUCTURE; REINFORCEMENT; CORROSION; HYDRATION; BEHAVIOR; HARDNESS; FIBERS;
D O I
10.1016/j.jobe.2023.106188
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The interfacial bond strength, which is the key to predict pullout behavior of steel fiber/wire/ rebar embedded in cement-based matrix, is usually determined by pullout tests. However, precise pullout test is difficult to be conducted, especially for steel fiber, due to the high accuracy requirements for equipment and operation process. In the present paper, a prediction model on interfacial bond strength between steel wire and cement mortar was developed, based on the interfacial porosity and matrix shrinkage, without conducting pullout test. Firstly, Backscattered Electron test was conducted to determine the interfacial porosity of the steel wire, Nanoindentation test was carried out to determine the elastic modulus of the interfacial zone, restraint ring test was conducted to determine the effective shrinkage deformation of the matrix. The results show that lower interfacial porosity causes higher elastic modulus of interfacial zone, the relationship between interfacial porosity and elastic modulus can be described by a first order fractional function. Then, the extrusion stress between streel wire and matrix was calculated based on the shrinkage deformation of matrix and elastic modulus of interfacial zone. Finally, the frictional bonding strength of interface was calculated based on the extrusion stress and friction coefficient. The calculated frictional bonding strengths for steel wire embedded in mortar with water-cement ratios of 0.25, 0.35, 0.45 and 0.55 are 4.24 MPa, 3.52 MPa, 2.81 MPa and 2.45 MPa, which are in good agreement with the measured bond strengths by pullout test. The prediction model can be extended to predict the pullout behavior of smooth plain steel fibers/wires/ rebars in cement-based material.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Bond behavior between high-strength steel wire meshes and ECC: Experimental study and analytical modelling
    Zhu, Juntao
    Liu, Yawen
    Li, Ziyuan
    Zou, Xuyan
    Li, Ke
    Fan, Jiajun
    ENGINEERING STRUCTURES, 2023, 287
  • [42] Application of the fracture mechanics on interfacial bond between steel and concrete
    Li, Lei
    Zheng, Shan-Suo
    Wang, Bin
    Gongcheng Lixue/Engineering Mechanics, 2009, 26 (12): : 52 - 57
  • [43] Shear modulus of the interfacial bond between steel fibres and concrete
    Hamoush, SA
    Terro, MJ
    Ahmad, SH
    MAGAZINE OF CONCRETE RESEARCH, 1997, 49 (181) : 277 - 282
  • [44] Interfacial bond-slip behavior between steel plate with studs and coated high-strength concrete
    Dong H.
    Zhao Y.
    Cao W.
    Chen X.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (02): : 122 - 130
  • [45] THE BOND STRENGTH OF A CALCIUM SULFOALUMINATE CEMENT-BASED REPAIR MORTAR
    Li, Xumin
    Xu, Chuanmin
    Du, Peng
    CERAMICS-SILIKATY, 2020, 64 (01) : 100 - 106
  • [46] Dynamic bond strength between CFRP sheet and steel
    Al-Zubaidy, Haider A.
    Zhao, Xiao-Ling
    Al-Mahaidi, Riadh
    COMPOSITE STRUCTURES, 2012, 94 (11) : 3258 - 3270
  • [47] Effects of ageing and storage conditions on the interfacial bond strength of steel fibers in mortars
    Huy Viet Le
    Moon, Doyoung
    Kim, Dong Joo
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 170 : 129 - 141
  • [48] Experiment Study on Interfacial Normal Bond Strength of Concrete Filled Steel Tube
    Liu, Zhen-yu
    ADVANCES IN INDUSTRIAL AND CIVIL ENGINEERING, PTS 1-4, 2012, 594-597 : 947 - 954
  • [49] Explicit neural network model for predicting FRP-concrete interfacial bond strength based on a large database
    Zhou, Yingwu
    Zheng, Songbin
    Huang, Zhenyu
    Sui, Lili
    Chen, Yang
    COMPOSITE STRUCTURES, 2020, 240
  • [50] COMPRESSIVE FAILURE OF SILICA-FILLED EPOXY-RESINS - INFLUENCE OF MATRIX STRENGTH, INTERFACIAL BOND STRENGTH AND POROSITY
    MOURITZ, AP
    HUTCHINGS, IM
    JOURNAL OF MATERIALS SCIENCE LETTERS, 1992, 11 (16) : 1100 - 1103