Selective Aptamer Modification of Au Surfaces in a Microelectrode Sensor Array for Simultaneous Detection of Multiple Analytes

被引:15
|
作者
Sen, Debashis [1 ,2 ]
Lazenby, Robert A. [1 ]
机构
[1] Florida State Univ, Dept Chem & Biochem, Tallahassee, FL 32306 USA
[2] Comilla Univ, Fac Sci, Dept Chem, Cumilla 3506, Bangladesh
关键词
IN-VITRO SELECTION; ELECTROCHEMICAL DNA; SENSITIVE DETECTION; APTASENSOR; MOLECULES; DOPAMINE; GOLD;
D O I
10.1021/acs.analchem.2c05335
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Aptamers have been employed as the biorecognition element in electrochemical aptamer-based (E-AB) biosensors, for the detection of a diverse range of analyte molecules, on electrodes with sizescales ranging from a few microns to several millimeters. Simultaneous detection of multiple different analytes requires the selective modification of multiple electrode surfaces with different aptamers. This process is typically achieved by incubating separate macroscale electrodes in a solution with the desired aptamer, which is unsuitable for microelectrode arrays in which the electrodes are closely spaced. In this work, we selectively modified electrode surfaces with thiolated aptamers of different single-stranded DNA sequences, by successive removal and addition of thiol monolayers. This was achieved by electrodesorption of thiol monolayers using controlled potential, to expose unmodified gold electrodes to be modified with a different thiolated aptamer, thus enabling multiple different aptamers to be used on the surfaces of closely spaced microelectrodes. All aptamers were methylene blue terminated, allowing redox currents to be measured and used to monitor aptamer probe packing density on the electrode surface and the selectivity of the sensors. Here, we demonstrate the microscale E-AB sensor multianalyte detection method using aptamers for target analytes, adenosine triphosphate, dopamine, and serotonin, which can ultimately be applied to perform localized simultaneous detection using electrode arrays.
引用
收藏
页码:6828 / 6835
页数:8
相关论文
共 50 条
  • [31] Multivariate Analysis of a Cobalt Octaethyl Porphyrin-Functionalized SWNT Microsensor Device for Selective and Simultaneous Detection of Multiple Analytes
    Shirsat, Sumedh M.
    Bodkhe, Gajanan A.
    Sonawane, Minakshi M.
    Gawali, Bharti W.
    Shirsat, Mahendra D.
    JOURNAL OF ELECTRONIC MATERIALS, 2021, 50 (10) : 5780 - 5787
  • [32] Multivariate Analysis of a Cobalt Octaethyl Porphyrin-Functionalized SWNT Microsensor Device for Selective and Simultaneous Detection of Multiple Analytes
    Sumedh M. Shirsat
    Gajanan A. Bodkhe
    Minakshi M. Sonawane
    Bharti W. Gawali
    Mahendra D. Shirsat
    Journal of Electronic Materials, 2021, 50 : 5780 - 5787
  • [33] An array immunosensor for simultaneous detection of clinical analytes (vol 71, pg 433, 1999)
    Rowe, CA
    Scruggs, SB
    Feldstein, MJ
    Golden, JP
    Ligler, FS
    ANALYTICAL CHEMISTRY, 2003, 75 (05) : 1225 - 1225
  • [34] Rapid capacitive detection of femtomolar levels of bisphenol A using an aptamer-modified disposable microelectrode array
    Haochen Cui
    Jayne Wu
    Shigetoshi Eda
    Jiangang Chen
    Wei Chen
    Lei Zheng
    Microchimica Acta, 2015, 182 : 2361 - 2367
  • [35] Rapid capacitive detection of femtomolar levels of bisphenol A using an aptamer-modified disposable microelectrode array
    Cui, Haochen
    Wu, Jayne
    Eda, Shigetoshi
    Chen, Jiangang
    Chen, Wei
    Zheng, Lei
    MICROCHIMICA ACTA, 2015, 182 (13-14) : 2361 - 2367
  • [36] Gradient-Based Colorimetric Array Sensor for Continuous Monitoring of Multiple Gas Analytes
    Lin, Chenwen
    Du, Zijian
    Tao, Nongjian
    Wang, Di
    ACS SENSORS, 2021, 6 (02) : 439 - 442
  • [37] Identification of multiple analytes using an optical sensor array and pattern recognition neural networks
    Johnson, SR
    Sutter, JM
    Engelhardt, HL
    Jurs, PC
    White, J
    Kauer, JS
    Dickinson, TA
    Walt, DR
    ANALYTICAL CHEMISTRY, 1997, 69 (22) : 4641 - 4648
  • [38] A serially cascaded micro-ring resonator for simultaneous detection of multiple analytes
    Butt, M. A.
    Khonina, S. N.
    Kazanskiy, N. L.
    LASER PHYSICS, 2019, 29 (04)
  • [39] Amperometric Electrochemical Sensor Array for On-Chip Simultaneous Imaging: Circuit and Microelectrode Design Considerations
    Hasegawa, Junichi
    Uno, Shigeyasu
    Nakazato, Kazuo
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (04)
  • [40] Microfluidic chip coupled with optical biosensors for simultaneous detection of multiple analytes: A review
    Liao, Zerong
    Zhang, Yang
    Li, Yongrui
    Miao, Yunfei
    Gao, Shimeng
    Lin, Fankai
    Deng, Yulin
    Geng, Lina
    BIOSENSORS & BIOELECTRONICS, 2019, 126 (697-706): : 697 - 706